<strong>EM</strong>G-1643 Digital Frequency· and Time Meter<br />

DFT MfiU rm 11<br />

5 (' r, ..<br />

; (. ' '<br />

The instrument is used for the measurement of frequency,<br />

frequency ratio, period time, average period time, totalizing<br />

time interval, totalizing count. The portable instrument contains<br />

only silicon transistors and is characterized by low weight and<br />

small size. It can be used for industrial and laboratory measurements.<br />

Frequency measurement:<br />

Period time measurement:<br />

Totalizing counting:<br />

Input voltage<br />

(i n case of sinusoidal signal) :<br />

Time interval and totalizing<br />

t ime interval measurement:<br />

Frequency ratio measurement:<br />

Operating temperature range:<br />

Change of reference frequency<br />

{between 0 °C and +SO 0 C) :<br />

Dimensions:<br />

c fs to 1.S Mcfs<br />

s to 10 f.'S<br />

cf s to 1.5 Mc/s<br />

200 mVrms to 1SO Yrms<br />

10 IJ.S to 9999 s<br />

fA= 1 cfs to 1.5 Mcfs<br />

fs=O to 100 kc/s<br />

0 °C to +SO °C<br />

max. 8.10- 5<br />

107x 26S x 212 mm<br />

<strong>EM</strong>G-1646 Digital Frequency- and Time Meter<br />

The basic instrument type <strong>EM</strong>G-1646 can be used to measure<br />

frequency in the range of 0 to 100 Mc fs, with the Frequency<br />

Converter plug-in unit type <strong>EM</strong>G-1689-U-82 the instrument<br />

can be used for frequency measurements up to 3,1 Gcfs. At time<br />

measurements the resolution of the instrument is 10 ns. The<br />

stability of the built-in time base generator is 5.10- 9 . The instrument<br />

is fully transistorized, the measured result appears on nine<br />

In-line numerical indicator tubes. A printer can be connected<br />

to the instrument, operated by a 4-line BCD code output signal.<br />

FREQUENCY MEASUR<strong>EM</strong>ENT<br />

Measuring range<br />

DC coupled input:<br />

AC coupled input:<br />

Gate time:<br />

PERIOD TIME MEASUR<strong>EM</strong>ENT<br />

Measuring range:<br />

At average period time measurement:<br />

Averaging factor :<br />

0 to 100 Mcfs<br />

100 cfs to 100 Mcfs<br />

1 f.'S to 10 s, can be<br />

adjusted in decadic<br />

steps<br />

0 to 1 Mc/s<br />

0 to 100 kc/s<br />

1 to 10 5 period,<br />

in decadic steps<br />

Frequency counted :<br />

OTHER DATA<br />

Sensitivity:<br />

Frequency of time base:<br />

Stability of time base:<br />

Dimensions:<br />

<strong>EM</strong>G-1689-U-82 Frequency Converter<br />

1 c/s to 100 Mcfs,<br />

in decadic steps<br />

(resolution in 10 ns)<br />

100 mV<br />

5 Mc/s<br />

5.10- 9<br />

177 x443 x 400 mm<br />

The Frequency Converter, as a plug-in unit, widens the field<br />

of application of the Digital Frequency and T ime Meter type<br />

<strong>EM</strong>G-1646. It ensures high-accuracy and high-resolution measurements<br />

in the frequency rangeof100 to 3100 Mcfs. It is fully<br />

transistorized .<br />

Frequency measurement:<br />

Sensitivity:<br />

Dimensions :<br />

100 to 3,100 Mc /s<br />

50 mV<br />

(100 to 2,500 Mcfs)<br />

100 mV<br />

(2,SOO to 3,100 Mcfs)<br />

160 x 120x210 mm<br />

1 0 0 0 0 0 p 0 ·Q ...<br />

I<br />

Manufactured by <strong>EM</strong>G<br />

WORKS FOR ELECTRONIC MEASURING GEAR<br />

Budapest XVI., Cziraky u. 26-32. HUNGARY<br />

Telex: 33-SO.<br />

Exported by<br />

METRIMPEX<br />

HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS<br />

Budapest, 62. P.O.B. 202<br />

Cable: INSTRUMENT, Budapest. HUNGARY<br />

" .2417 E1yetemi Nyomda m"yr.yomua, Buclap•t<br />

(Ma1yar Hlrdet6)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!