ORION EM G
ORION EM G
ORION EM G
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>EM</strong>G-1363 TR-1653 Integrating Digital DC Voltmeter<br />
The instrument has been designed for measuring DC voltages<br />
within a very wide voltage range (10 !J.Y to 1,000 V) with 0.05%<br />
accuracy. The measurement result is displayed by four in-line<br />
numerical indicator tubes. The application of integrating technics<br />
ensures efficient common mode rejection.<br />
Measu ri ng range:<br />
Measuring ranges:<br />
Measuring accuracy:<br />
Period time of one measurement:<br />
Dimensions:<br />
10 !J.Y to 1,000 V<br />
(in 6 ranges)<br />
20, 200 mY,<br />
2, 20, 200, 1,000 v<br />
±0.05%<br />
± 1 digit of f.s.<br />
30 ms<br />
135 x440x375 mm<br />
<strong>EM</strong>G-1366 TR-1754 ACJDC and ResistancefDC Converter<br />
Connected to the <strong>EM</strong>G-1363 Integrating Digital DC Voltmeter,<br />
the instrument is suitable for high accuracy measurement of AC<br />
voltages as well as resistances.<br />
AC VOLTAGE MEASUR<strong>EM</strong>ENT<br />
Measuring range :<br />
Measuring accuracy<br />
50 cfs to 50 kc/s:<br />
20 cfs to 500 kc/s:<br />
RESISTANCE MEASUR<strong>EM</strong> ENT<br />
Measurement range:<br />
Measuring accuracy<br />
200 ohms to 2 Mohms :<br />
2 Mohms to 20 Mohms :<br />
Dimensions:<br />
100 !J.V to 200 V<br />
(in 5 ranges)<br />
± 0.5% of f.s.<br />
±2% of f.s.<br />
0.1 ohm to 20 Mohms<br />
(in 6 ran~es)<br />
± 0 . ~% of f.s.<br />
±0.5% of f.s.<br />
90 x 440 x 430 mm<br />
"' 4 ~;<br />
I<br />
c; c<br />
TfPf , __<br />
DlGIUL MULTIIHTft<br />
<strong>EM</strong>G-1364 TR-1654 Digital Multimeter<br />
The instrument can be used for fast and accurate measurement<br />
of AC and DC voltages as well as resistances. The measured result<br />
is displayed by four in-line numerical indicator tubes.<br />
DC VOLTAGE MEASUR<strong>EM</strong>ENT<br />
Measuring range:<br />
Measuring ranges:<br />
Measuring accuracy :<br />
Period t ime of one measurement:<br />
AC VOLTAGE MEASUR<strong>EM</strong>ENT<br />
Measuring range:<br />
Measuring accuracy:<br />
Frequency range:<br />
RESISTANCE MEASUR<strong>EM</strong>ENT<br />
Measuring range:<br />
Measuring accuracy :<br />
Dimensions:<br />
2 mY to 500 V<br />
(in 3 ranges)<br />
5, 50, 500 v<br />
± 0.2% ±2 digits<br />
300 ms<br />
2 mY to 300 V<br />
(in 3 ranges)<br />
± 0.2%±2 digits<br />
40 cfs t o 10 kc/s<br />
2 o hms to 500 kohm s<br />
(in 3 ranges)<br />
± 0.5%± 2 digits<br />
107 x 265 x 310 mm<br />
<strong>EM</strong>G-1369 TR-2251 Digital Resistance Meter<br />
The instrument is used for highly accurate measurement of<br />
resistances. The measured result appears on five in-line numerical<br />
indicator tubes.<br />
Measuring range:<br />
Measuring accuracy:<br />
Measuring time:<br />
DImensions:<br />
5 mohms<br />
to 200 Mohms<br />
(in 8 ranges)<br />
±0.04% of f.s.<br />
380 ms<br />
180x436x360 mm