<strong>EM</strong>G -1325 TR -1 351 RF Millivoltmeter<br />

The instrument is used for measuring AC voltages between 1 mV and 10 V in the<br />

frequency range of 0.5 to 1,000 Mcfs. The measuring range can be extended up to<br />

1,000 V by means of a divider. The RF measurements can be performed by means of<br />

several measuring probes. The instrument is fully transistorized.<br />

Measuring range:<br />

Frequency range:<br />

M easu ring accuracy<br />

0.5 to 50 Mcjs :<br />

50 to 150 Mcjs :<br />

150 to 1,000 Mcfs :<br />

Dim ensions:<br />

1 mV to 10 V<br />

(in 7 ranges)<br />

0.5 to 1,000 Mcfs<br />

±3% f.s.d.<br />

±6% f.s.d.<br />

±1 dB f.s.d.<br />

247 X 196 X 300 mm<br />

<strong>EM</strong>G-1353 TR-1453 Transistorized AC Voltmeter<br />

The instrument is used for measuring AC voltages between<br />

100 fi.V to 300 V in the frequency range of 1 cfs to 1 Mcfs. It is<br />

fully transistorized, small size, can be operated from battery.<br />

Measuring range:<br />

Measuring accuracy :<br />

Frequency range:<br />

Frequency response<br />

(related to 1 kcfs)<br />

5 cfs to 500 kcjs :<br />

1 to 5 cfs, or<br />

500 to 1,000 kc/s, resp.:<br />

Dimensions:<br />

DC AMMETER<br />

<strong>EM</strong>G-1J48 TR-1104 DC Milliammeter<br />

100 fi.Y to 300 V<br />

(in 12 ranges)<br />

±3% f.s.d.<br />

1 cjs to 1 Mcjs<br />

±3%<br />

±5%<br />

165 x 180 x1 10 mm<br />

The instrument can be used for measuring DC in the range of<br />

0 .3 mA to 1 A. The current can be measured without breaking<br />

the circuit, by means of a measuring probe damped on the<br />

conductor.<br />

Measuring range:<br />

Measuring accuracy:<br />

Dimensions :<br />

0.3 rnA to 1 A<br />

(in 6 ranges)<br />

± 3% f.s.d.<br />

236 x 180 x 320 mm<br />

DC VOLTMETER-AMMETER<br />

<strong>EM</strong>G-1352 TR-1452 DC Microvolt-Ammeter<br />

The instrument is suitable for measu ring very low positive and<br />

negative DC voltages and currents. It can be used as a DC<br />

amplifier.<br />

VOLTAGE MEASUR<strong>EM</strong>ENT<br />

Measuring range:<br />

Measuring accuracy :<br />

CURRENT MEASUR<strong>EM</strong>ENT<br />

Measuring range :<br />

Measuring accu racy:<br />

Dimensions:<br />

1 t,J.Y to 1 V (±)<br />

±3% f.s.d.<br />

1 pA to 3 rnA (±)<br />

±3% f.s.d.<br />

247 x 196 x 300 mm