...._____.,._ EL_ECTRONIC VOLTMETERS AND AMMET_ER_S~____,<br />
ELECTRONIC VOLTMETERS FOR AC VOLTAGE MEASUR<strong>EM</strong>ENTS<br />
<strong>EM</strong>G-1314 TR-1103 V.T. Voltmeter<br />
The Instrument is a Y.T.Y.M., of a very stable amplifier system.<br />
It is used for measuring AC voltages between 5 mY and 300 V<br />
in the frequency range of 10 c/s to 1 Mcfs. It can also be used as<br />
a measuring amplifier.<br />
Measuring range :<br />
Measuring accuracy (at 1 kc/s):<br />
Frequency range :<br />
Frequency response<br />
(related to 1 kc/s)<br />
20 cfs to 300 kc/s:<br />
10 to 20 cfs, or<br />
300 to 1,000 kcfs, resp.:<br />
Dimensions :<br />
5 mY to 300 Y<br />
(in 9 ranges)<br />
±2% f.s.d.<br />
10 cfs to 1 Mcfs<br />
±2%<br />
<strong>EM</strong>G-1319 TR-1202 Sensitive V.T. Voltmeter<br />
±5%<br />
236 x 180 x 250 mm<br />
The Instrument is used for measuring symmetrical and asymmetrical<br />
AC voltages between 50 fLY and 300 Y in frequency range<br />
of 10 cfs to 1 Mcfs. It can also be used as a measuring amplifier.<br />
ASYMMETRICAL INPUT<br />
Measuring range:<br />
Measuring accuracy<br />
(at 1 kc/s):<br />
Frequency range :<br />
Frequency response<br />
(related to 1 kc/s)<br />
20 cfs to 300 kcfs :<br />
50 fLY to 300 V<br />
(in 13 ranges)<br />
± 2% f.s.d.<br />
10 cfs to 1 Mcfs<br />
± 2%<br />
10 to 20 cfs, or<br />
300 to 1,000 kc/s, resp.:<br />
SYMMETRICAL INPUT<br />
± S%<br />
Measuring range:<br />
SO !J.Y to 10 V<br />
Measuring accuracy:<br />
±3% f.s.d.<br />
Frequency range :<br />
60 cfs to 20 kc/s. or<br />
3 kcfs to 300 kc/s,<br />
resp.<br />
Dimensions:<br />
26S x 200 x 28S mm<br />
<strong>EM</strong>G-1322 TR-1204 Precision V.T . Voltmeter<br />
The instrument is a very accurate, high stability V.T. Voltmeter,<br />
which can be used for measuring AC voltages between SO fLY<br />
and 300 V in the frequency range of 10 cfs to 5 Mc/s. Owing to<br />
the high accuracy obtained, it is also suitable for laboratory<br />
precision measurements.<br />
Measuring range :<br />
Measuring accuracy<br />
(at 1 kcfs):<br />
Frequency range:<br />
Frequency response<br />
(related to 1 kc/s)<br />
50 cfs to SOO kcfs:<br />
20 to SO cfs, or<br />
SOO to 1,000 kcfs, resp.:<br />
10 to 20 cfs, or<br />
1 to 5 Mcfs, resp.:<br />
Dimensions :<br />
SO fLY to 300. Y<br />
(in 12 ranges)<br />
± 1% f.s.d.<br />
10 cfs to S Mcfs<br />
±1%<br />
±2%<br />
±5%<br />
26S x 200x28S mm<br />
<strong>EM</strong>G-1324 TR-1301 Wide Band V.T. Voltmeter<br />
The instrument Is designed for measuring low-level AC voltages over a<br />
wide frequency range. The signal to be measured reaches the measuring<br />
probe either directly, or at low-level signal measurement, through a<br />
pre-divider.<br />
Measuring range:<br />
Measuring accuracy :<br />
Frequency range :<br />
Frequency response<br />
(related to SO kc/s)<br />
1 kc/s to 10 Mcfs :<br />
10 Mcfs to 30 Mc/s :<br />
(without pre-divider)<br />
Dimensions:<br />
100 !J.Y to 30 Y<br />
(in 10 ranges)<br />
±3% f.s.d.<br />
1 kc/s to 30 Mcfs<br />
±S%<br />
±8%<br />
26S x 200 x 36S mm