3. Installation - Configuration (continued)<br />

14<br />

Check Operation - Fan Speed Select<br />

IN3<br />

) K J<br />

BB<br />

OUT1, 2, 3<br />

# <br />

<br />

<br />

If Occupied and Remote Fan Speed (K7) Auto<br />

Fan Speed Switch can be provided by TB/TS/KEF or<br />

RD-IQL/KOSF (see section 1.3 step 8)<br />

Set up Strategy Parameters<br />

15 if required<br />

Use IqlTool2 (see section 2.2 step 5 ) and text<br />

communications<br />

For standard strategies use table below, else refer to<br />

non-standard strategy installation instructions<br />

Parameter<br />

K1(V)<br />

K2(V)<br />

K3(V)<br />

K4(V)<br />

K5(V)<br />

K6(V)<br />

K7(V)<br />

K8(V)<br />

Label<br />

Remote<br />

Setpoint<br />

RemoteSpaceTemp<br />

OCC Deadbnd<br />

Standby<br />

Deadbnd<br />

NOCC Deadbnd<br />

Remote<br />

Occ<br />

Remote<br />

Fan Spd<br />

Remote<br />

SP Offset<br />

Function<br />

Base<br />

setpoint can be adjusted remotely<br />

Used<br />

if bound to Lon sensor, or if local sensor disconnected<br />

Deadband<br />

around setpoint during Occ<br />

Deadband<br />

around setpoint during Standby<br />

Deadband<br />

around setpoint during Nocc<br />

Sets<br />

state 0=Occ, 1=Nocc, 2=Bypass, 3=Standby<br />

Sets<br />

speed 0=off, 1=Low, 2=Med, 3=High, 4=Auto<br />

Used<br />

if bound to a Lon Sensor or if local adjust is disconnected<br />

20 ° C<br />

20 ° C<br />

1 ° C<br />

2 ° C<br />

12 ° C<br />

Default<br />

0=Occupied<br />

4=Auto<br />

0 ° C<br />

K15(V)<br />

W2(S)<br />

W3(S)<br />

O ffset range<br />

Defines<br />

range of Local SP adjust pot.<br />

S ummer Mode<br />

Winter<br />

(heat only) or Summer (cool only) (only used for /WR2, /WT2)<br />

Elec<br />

Disable<br />

Disable<br />

Electric Heater if set to I<br />

2 ° C<br />

O=Winter<br />

O=enable Elec<br />

W5(S)<br />

W6(S)<br />

W7(S)<br />

W8(S)<br />

L1(G)<br />

L1(I)<br />

L2(G)<br />

L2(I)<br />

Window mode<br />

O=Pb<br />

I=PIR<br />

Frost<br />

Condition<br />

Remote<br />

Shutdown<br />

Window contact if set to I, alarm contact if set to O<br />

PIR if set to I, Pushbutton if set to O<br />

Overrides<br />

heating to 98 % (not /AR2) if unoccupied<br />

Shuts<br />

off fan, and sets heat/cool to zero<br />

Heat<br />

Loop Gain<br />

40<br />

Heat<br />

Loop Integral<br />

Cool<br />

Loop Gain<br />

-40<br />

Cool<br />

Loop Integral<br />

O=alarm contact<br />

O=pushbutton<br />

O=no frost<br />

O=no shutdown<br />

0 mins<br />

0 mins<br />

Note that any changes to the strategy parameters should immediately be followed by a write to the address<br />

module, [text comms command, R(z=O), recommended], to commit changes to flash memory.<br />

If used with RD-IQL (see section 1.3 step 8), the following must be configured: Local Space Temp Type<br />

S9(Y=6), Local SP Adjust Type S10(Y=6), Local Fan Speed Type S11(Y=6), O=Pb I=PIR W6(S=O)<br />

default, Remote Fan Spd K7(V=4) default, followed by R(z=I) to write changes to flash and reset.<br />

Configuration for RD-IQL is facilitated by IqlTool2.<br />

If the sensor on IN1 is to be used, leave local Space Temp Type at default, S9(Y=1). If the fan speed<br />

switch on IN3 is to be used, leave Local Fan Speed type at default, S11 (Y=3).<br />

If required the strategy type may be changed (e.g. /AR2 to /WR2) but<br />

a /E strategy cannot be changed to a /AUX strategy or vice versa:<br />

IQL15+/xxx data<br />

sheet TA200367