RH + T INDICATOR WITH RS485<br />
ISOLATED RS485, IP65, DUAL LCD DISPLAY<br />
SC808<br />
DIMENSIONAL DETAILS<br />
82<br />
WALL/SURFACE MOUNT<br />
Fig 4 Fig 5<br />
DUCT MOUNT<br />
35<br />
82<br />
80<br />
½ ” BSP(M), ACF<br />
Filter<br />
12<br />
SC808<br />
RH + TEMPERATURE RS485 MODULE<br />
80<br />
SC808<br />
RH + TEMPERATURE RS485 MODULE<br />
42<br />
L<br />
30<br />
L<br />
L<br />
35<br />
4<br />
30<br />
30<br />
Filter<br />
12<br />
Filter<br />
12<br />
DEFAULT COMMUNICATION PARAMETERS<br />
The default configuration shown in Table 1 will be supplied,<br />
unless a user specifies and orders a different configuration<br />
( see Table 2 )<br />
USER SPECIFIED COMMUNICATION PARAMETERS<br />
If the user wishes the instrument to be supplied with a<br />
configuration specified by him, he must give the following<br />
information while ordering :<br />
TABLE 1 TABLE 2<br />
Baudrate<br />
Parity<br />
Stop bits<br />
Data format<br />
9600<br />
None<br />
1<br />
Float<br />
Note : To change the default configuration, the user will need<br />
the PC Configurator PCC82.<br />
Parameter<br />
Baudrate<br />
Parity<br />
Stop bits<br />
Data format<br />
User to fill<br />
Suggested values<br />
1<br />
Float<br />
ORDERING INFORMATION<br />
SC808 - Surface / Wall Mount will be supplied<br />
with the following standard specifications :<br />
Immersion length (L)<br />
Filter<br />
Sensor break<br />
ORDER CODE : 2341<br />
Ordering Options<br />
The following ordering options are available on request.<br />
Minimum order quantity and/or minimum order value may apply.<br />
Option ID<br />
1.<br />
2.<br />
3.<br />
4.<br />
70 mm (See Fig 4)<br />
Sintered bronze<br />
> 20 mA<br />
Option details<br />
Customer specified immersion length (>70 mm)<br />
Remote sensor (upto 25 meters from instrument)<br />
User specified communication parameters<br />
SS wiremesh filter<br />
SC808 - Duct Mount will be supplied<br />
with the following standard specifications :<br />
Immersion length (L)<br />
Filter<br />
Sensor break<br />
ORDER CODE : 2327<br />
Option ID<br />
1.<br />
2.<br />
3.<br />
300 mm (See Fig 5)<br />
Sintered bronze<br />
> 20 mA<br />
Ordering Options<br />
The following ordering options are available on request.<br />
Minimum order quantity and/or minimum order value may apply.<br />
Option details<br />
Customer specified immersion length<br />
SS wiremesh filter<br />
User specified communication parameters<br />
PC CONFIGURATOR - PCC82 Order code 2304<br />
AN ISO 9001:2008 COMPANY<br />
INSTRUMENTS T : + 91 22 42537777 x 701 F : + 91 22 42537700 E : sales@radix.co.in<br />
SENSORS T : + 91 22 42537777 x 732 F : + 91 22 42537700 E : sensors@radix.co.in<br />
GAUGES T : + 91 22 42537777 x 733 F : + 91 22 42537700 E : gauges@radix.co.in<br />
AUTOMATION C : 0-9322405471 C : 0-9324319150 E : automation@radix.co.in<br />
<strong>Radix</strong> Electrosystems Pvt Ltd, B-14, 2nd Floor, Ghanshyam Indl Estate, Veera Desai Road, Andheri (West), Mumbai - 400 053, India<br />
Tel : + 91 22 42537777 Fax : + 91 22 42537700 Email : sales@radix.co.in www.radix.co.in<br />
www.radix.co.in<br />
CAT#379R1/P4/4/310312/A