NSN 4520-01-444-2375<br />
TM 10-4520-261-12P<br />
Lighting the stove<br />
(1) Tip fuel can and let stove prime for 2 to 5 minutes.<br />
(2) Hold the priming cup under priming valve on fuel supply hose. Open the valve<br />
slowly and fill the cup with fuel.<br />
(3) Pour fuel into the bottom of burner. If the outside temperature is below -25º F,<br />
pour one additional cup.<br />
(4) Take one square of tissue or paper and soak up any excess fuel that may<br />
remain in the cup.<br />
(5) Light the fuel soaked tissue and toss it into the bottom of the burner. Use the<br />
cleaning tool, if necessary, to make sure that the burning tissue reaches the<br />
bottom of the burner where it can ignite the priming fuel. Close the Lid Assembly.<br />
(6) When the heater has warmed up sufficiently and begins to give off heat,<br />
gradually adjust the flow adjustment knob to desired heat output.<br />
*Operators require license to operate SHA