FOR MODELS: JGZ AND JGU SECTION 4 LUBRICATION<br />

Time since last Pulse - It is helpful to have a display of the timer timing so the operator<br />

can see a change and show that something is happening.<br />

Average Cycle Time - Cycle time will vary a few seconds from cycle to cycle. It is<br />

sometimes helpful to display a cycle time that has been averaged over 5 to 10 cycles.<br />

Total Oil Consumed - Total oil consumed can be useful to the operator to know<br />

how much oil is being used for the lube system and thus how much oil to order.<br />

4. EXAMPLE FLOW DIAGRAM TO CREATE SHUTDOWN<br />

Figure 4-7 flow diagram is a suggested method of creating a shutdown within the<br />

PLC from a cycling digital input. This is only a suggestion as there is no way of<br />

providing logic for all control systems.<br />

Start<br />

Initialize Timer<br />

Read Lube<br />

Digital Input<br />

Prox. Switch<br />

OFF to ON?<br />

F<br />

Is Timer >3<br />

Minutes?<br />

No Shutdown<br />

to Output<br />

End<br />

T<br />

T<br />

F F<br />

Stop Timer<br />

Start Reset<br />

Timer<br />

Unit Running<br />

Class B Timer?<br />

T = True<br />

F = False<br />

Increment<br />

Counter<br />

Calculate Total<br />

Oil Flow<br />

Send Shutdown<br />

Signal Output<br />

FIGURE 4-7 SUGGESTED FORCE FEED LUBE CONTROL SYSTEM PROXIMITY SWITCH<br />

SHUTDOWN LOGIC DIAGRAM<br />

7/09 PAGE 4 - 23<br />