FOR MODELS: JGZ AND JGU SECTION 4 LUBRICATION<br />
vice visit the vendor literature section of the <strong>Ariel</strong> web site.<br />
TABLE 4-5 FORCE FEED LUBE SYSTEM MONITORS - SPECIFICATIONS<br />
ITEM PROFLO KENCO DNFT<br />
DNFT -<br />
PROGRAMMABLE<br />
Shutdown Signal YES NO YES YES<br />
Proximity Signal YES (0.5 sec pulse) YES (switch) YES (switch) YES (switch)<br />
Local Data Storage YES NO NO Count Display<br />
Infrared Port YES NO NO NO<br />
PLC Creates<br />
Shutdown<br />
NO YES NO NO<br />
Remote Mounting YES NO NO NO<br />
Area Classification CSA CSA CSA, CE, EX, ATEX CSA, CE<br />
CSA<br />
203633 Class I,<br />
Div 2, Groups<br />
ABCD T4A<br />
044787 Class I,<br />
Groups ABCD:<br />
Class II, Groups EFG:<br />
Class III<br />
CE N/A N/A<br />
I. Shutdown switch - This is a device that monitors the position of the divider block pin and<br />
supplies a shutdown contact. If the divider block stops cycling for a given time a shutdown signal<br />
will be sent to the control system.<br />
APPLICATION NOTES - Shutdown Switch<br />
108334 Class I, Div 1<br />
Groups ABCD T5; &/<br />
or Class I, Zone 1 Ex<br />
md IIC T5<br />
0344 Class I Div 1;<br />
Groups ABCD T4<br />
Normally open (NO) vs. Normally closed (NC) Shutdown switch<br />
108334 Class I, Div 1<br />
Groups ABCD T5; &/<br />
or Class I, Zone 1 Ex<br />
md IIC T5<br />
0344 Class I Div 1;<br />
Groups ABCD T4<br />
EX N/A N/A II 2G EEx mIIB T5 N/A<br />
KEMA N/A N/A<br />
Battery<br />
Cost Factor New<br />
Unit<br />
(2) Energizer Lithium<br />
“AA” Size<br />
00ATEX1090X/<br />
AMB. -40°C to +85°C<br />
Divider block monitoring devices define their operation opposite from other industries. Most<br />
other industries define the switch state as the state the switch is in when it is on the shelf.<br />
(That is: If a momentary push button switch is NO, then when it is taken out of the box the<br />
7/09 PAGE 4 - 21<br />
N/A<br />
None <strong>Ariel</strong> P/N A-10807 <strong>Ariel</strong> P/N A-10807<br />
$0 Standard Minus $ $0 Standard for CE Plus $<br />
Shutdown Time Programmable PLC 3 minutes<br />
Temperature to185°F (85°C) to 220°F (104°C)<br />
-40°F to +185°F (-<br />
40°C to +85°C)<br />
Programmable<br />
20 sec. to 4 minutes<br />
-40°F to +185°F<br />
(-40°C to +85°C)<br />
Max. Switch Voltage 36 VDC 200 VAC/VDC 240 VDC 10 to 120 VAC<br />
Max. Switch Current 0.5 Amps 0.5 Amps N/A N/A<br />
Max. Switch Power N/A 10 Watts DC 2.5 VA 2.5 VA<br />
Local Cycle Indicator YES - LCD Separate Indicator YES - Flashing LED<br />
YES -<br />
LCD Display +LED<br />
De-bounce Included NO NO YES YES