FOR MODELS: JGZ AND JGU SECTION 4 LUBRICATION<br />

vice visit the vendor literature section of the <strong>Ariel</strong> web site.<br />

TABLE 4-5 FORCE FEED LUBE SYSTEM MONITORS - SPECIFICATIONS<br />

ITEM PROFLO KENCO DNFT<br />

DNFT -<br />

PROGRAMMABLE<br />

Shutdown Signal YES NO YES YES<br />

Proximity Signal YES (0.5 sec pulse) YES (switch) YES (switch) YES (switch)<br />

Local Data Storage YES NO NO Count Display<br />

Infrared Port YES NO NO NO<br />

PLC Creates<br />

Shutdown<br />

NO YES NO NO<br />

Remote Mounting YES NO NO NO<br />

Area Classification CSA CSA CSA, CE, EX, ATEX CSA, CE<br />

CSA<br />

203633 Class I,<br />

Div 2, Groups<br />

ABCD T4A<br />

044787 Class I,<br />

Groups ABCD:<br />

Class II, Groups EFG:<br />

Class III<br />

CE N/A N/A<br />

I. Shutdown switch - This is a device that monitors the position of the divider block pin and<br />

supplies a shutdown contact. If the divider block stops cycling for a given time a shutdown signal<br />

will be sent to the control system.<br />

APPLICATION NOTES - Shutdown Switch<br />

108334 Class I, Div 1<br />

Groups ABCD T5; &/<br />

or Class I, Zone 1 Ex<br />

md IIC T5<br />

0344 Class I Div 1;<br />

Groups ABCD T4<br />

Normally open (NO) vs. Normally closed (NC) Shutdown switch<br />

108334 Class I, Div 1<br />

Groups ABCD T5; &/<br />

or Class I, Zone 1 Ex<br />

md IIC T5<br />

0344 Class I Div 1;<br />

Groups ABCD T4<br />

EX N/A N/A II 2G EEx mIIB T5 N/A<br />

KEMA N/A N/A<br />

Battery<br />

Cost Factor New<br />

Unit<br />

(2) Energizer Lithium<br />

“AA” Size<br />

00ATEX1090X/<br />

AMB. -40°C to +85°C<br />

Divider block monitoring devices define their operation opposite from other industries. Most<br />

other industries define the switch state as the state the switch is in when it is on the shelf.<br />

(That is: If a momentary push button switch is NO, then when it is taken out of the box the<br />

7/09 PAGE 4 - 21<br />

N/A<br />

None <strong>Ariel</strong> P/N A-10807 <strong>Ariel</strong> P/N A-10807<br />

$0 Standard Minus $ $0 Standard for CE Plus $<br />

Shutdown Time Programmable PLC 3 minutes<br />

Temperature to185°F (85°C) to 220°F (104°C)<br />

-40°F to +185°F (-<br />

40°C to +85°C)<br />

Programmable<br />

20 sec. to 4 minutes<br />

-40°F to +185°F<br />

(-40°C to +85°C)<br />

Max. Switch Voltage 36 VDC 200 VAC/VDC 240 VDC 10 to 120 VAC<br />

Max. Switch Current 0.5 Amps 0.5 Amps N/A N/A<br />

Max. Switch Power N/A 10 Watts DC 2.5 VA 2.5 VA<br />

Local Cycle Indicator YES - LCD Separate Indicator YES - Flashing LED<br />

YES -<br />

LCD Display +LED<br />

De-bounce Included NO NO YES YES