FOR MODELS: JGZ AND JGU SECTION 5 - MAINTENANCE<br />

BEARING LOG FORM/CONDITIONS AFTER REPLACING BEARINGS<br />

SERIAL NO. F- MODEL Date<br />

CRANKSHAFT THRUST (END) CLEARANCE:<br />

CRANKSHAFT SERIAL NUMBER THRUST CLEARANCE, IN. (mm)<br />

CONNECTING ROD THRUST (SIDE) CLEARANCE, IN. (mm)<br />

THROW<br />

NUMBER:<br />

JACK CLEARANCES, IN. (mm)<br />

THROW<br />

NUMBER:<br />

MAIN<br />

BEARINGS<br />

CONN. ROD<br />

BEARINGS<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

If measured clearances exceed the tolerances in Section 1, after installing new bearings, contact your packager or <strong>Ariel</strong> before proceeding.<br />

DATE TIME RPM<br />

OIL PRESSURE<br />

FILTER INLET<br />

PSIG (BAR G )<br />

OIL PRESSURE<br />

FILTER OUTLET<br />

PSIG (BAR G )<br />

OIL<br />

TEMPERATURE<br />

INTO FRAME<br />

°F (°C)<br />

BEARING CAP TEMPERATURES, °F (°C), AFTER RUN TIME OF:<br />

THROW<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

10 MINUTES 1 HOUR 4 HOURS<br />

REMARKS<br />

MAIN ROD MAIN ROD MAIN ROD<br />

PAGE 5 - 68 7/09