Heavy Duty Balanced Opposed Compressors - Ariel Corporation
Heavy Duty Balanced Opposed Compressors - Ariel Corporation
Heavy Duty Balanced Opposed Compressors - Ariel Corporation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FOR MODELS: JGZ AND JGU SECTION 1 - DESIGN SPECIFICATIONS & DATA<br />
Table 1-3 JGU FRAME SPECIFICATIONS a<br />
MODEL JGU/2 JGU/4 JGU/6<br />
Stroke, inches (mm) 5.75 (146) 5.75 (146) 5.75 (146)<br />
Speed, RPMb 600 To 1200 600 To 1200 600 To 1200<br />
Piston Speed, FPM (m/s) To 1150 (5.84) To 1150 (5.84) To 1150 (5.84)<br />
Number of Throws 2 4 6<br />
Horsepower (kW) To 2600 (1939) To 5200 (3878) To 7800 (5616)<br />
Height - Bottom to Crankshaft Cen- 24.000<br />
24.000<br />
24.000<br />
terline, Nominal, in. (mm)<br />
(609.6)<br />
(609.6)<br />
(609.6)<br />
Connecting Rod Centerline to Cen- 18.500<br />
18.500<br />
18.500<br />
terline, Nominal, in. (mm)<br />
(469.9)<br />
(469.9)<br />
(469.9)<br />
Maximum Width with Cylinders,<br />
186<br />
186<br />
186<br />
in. (m)<br />
(4.72)<br />
(4.72)<br />
(4.72)<br />
Maximum Length, in. (m) 87 (2.21) 135 (3.43) 183 (4.65)<br />
Maximum Height, in. (m) 42 (1.07) 42 (1.07) 42 (1.07)<br />
Approximate Weight with<br />
22,500<br />
45,000<br />
67,000<br />
Cylinders, lb. (kg)<br />
(10 200) (20 500) (30 500)<br />
Oil Pump Flow Rate @ Max. Rated<br />
Speed & 180°F (82°C), GPM (L/s)<br />
42 (2.6) 101 (6.4) 135 (8.5)<br />
Oil Heat Rejection, BTU/hr. (kW)<br />
70,000<br />
(20.5)<br />
140,000<br />
(41.0)<br />
210,000<br />
(61.6)<br />
Oil Sump Capacity, US gallons (L) 40 (150) 77 (290) 107 (405)<br />
Piston Rod Diameter, Nominal,<br />
in. (mm)<br />
2.875<br />
(73)<br />
2.875<br />
(73)<br />
2.875<br />
(73)<br />
Maximum Internal Rod Load - Double Acting:<br />
Compression + Tension, lbf. (kN) 150,000 (667) 150,000 (667) 150,000 (667)<br />
Tension, lbf. (kN) 75,000 (334) 75,000 (334) 75,000 (334)<br />
Compression, lbf. (kN) 80,000 (356) 80,000 (356) 80,000 (356)<br />
Maximum Internal Rod Load - Single Acting:<br />
Tension, lbf. (kN) 75,000 (334) 75,000 (334) 75,000 (334)<br />
a. For more information, see the Electronic Databook available in the <strong>Ariel</strong> Performance Program.<br />
b. Rated speeds for non-lube, and lubricated process applications may vary. Minimum speed required<br />
to provide adequate oil flow to the compressor bearings by the frame driven oil pump.<br />
7/09 PAGE 1 - 5