FOR MODELS: JGZ AND JGU SECTION 1 - DESIGN SPECIFICATIONS & DATA<br />

Table 1-3 JGU FRAME SPECIFICATIONS a<br />

MODEL JGU/2 JGU/4 JGU/6<br />

Stroke, inches (mm) 5.75 (146) 5.75 (146) 5.75 (146)<br />

Speed, RPMb 600 To 1200 600 To 1200 600 To 1200<br />

Piston Speed, FPM (m/s) To 1150 (5.84) To 1150 (5.84) To 1150 (5.84)<br />

Number of Throws 2 4 6<br />

Horsepower (kW) To 2600 (1939) To 5200 (3878) To 7800 (5616)<br />

Height - Bottom to Crankshaft Cen- 24.000<br />

24.000<br />

24.000<br />

terline, Nominal, in. (mm)<br />

(609.6)<br />

(609.6)<br />

(609.6)<br />

Connecting Rod Centerline to Cen- 18.500<br />

18.500<br />

18.500<br />

terline, Nominal, in. (mm)<br />

(469.9)<br />

(469.9)<br />

(469.9)<br />

Maximum Width with Cylinders,<br />

186<br />

186<br />

186<br />

in. (m)<br />

(4.72)<br />

(4.72)<br />

(4.72)<br />

Maximum Length, in. (m) 87 (2.21) 135 (3.43) 183 (4.65)<br />

Maximum Height, in. (m) 42 (1.07) 42 (1.07) 42 (1.07)<br />

Approximate Weight with<br />

22,500<br />

45,000<br />

67,000<br />

Cylinders, lb. (kg)<br />

(10 200) (20 500) (30 500)<br />

Oil Pump Flow Rate @ Max. Rated<br />

Speed & 180°F (82°C), GPM (L/s)<br />

42 (2.6) 101 (6.4) 135 (8.5)<br />

Oil Heat Rejection, BTU/hr. (kW)<br />

70,000<br />

(20.5)<br />

140,000<br />

(41.0)<br />

210,000<br />

(61.6)<br />

Oil Sump Capacity, US gallons (L) 40 (150) 77 (290) 107 (405)<br />

Piston Rod Diameter, Nominal,<br />

in. (mm)<br />

2.875<br />

(73)<br />

2.875<br />

(73)<br />

2.875<br />

(73)<br />

Maximum Internal Rod Load - Double Acting:<br />

Compression + Tension, lbf. (kN) 150,000 (667) 150,000 (667) 150,000 (667)<br />

Tension, lbf. (kN) 75,000 (334) 75,000 (334) 75,000 (334)<br />

Compression, lbf. (kN) 80,000 (356) 80,000 (356) 80,000 (356)<br />

Maximum Internal Rod Load - Single Acting:<br />

Tension, lbf. (kN) 75,000 (334) 75,000 (334) 75,000 (334)<br />

a. For more information, see the Electronic Databook available in the <strong>Ariel</strong> Performance Program.<br />

b. Rated speeds for non-lube, and lubricated process applications may vary. Minimum speed required<br />

to provide adequate oil flow to the compressor bearings by the frame driven oil pump.<br />

7/09 PAGE 1 - 5