FOR MODELS: JGZ AND JGU SECTION 4 LUBRICATION<br />
to make the “normal” cycle time, to maintain a stroke greater than 20% in the functioning<br />
pump(s).<br />
Running Conditions<br />
When the machine is running, make sure that the oil level in the lubricator reservoir is at least<br />
one-half way up the sight level, but does not exceed two-thirds.<br />
See your packager's specific data to determine the normal operating conditions, the cylinder<br />
working pressures, and the rated speed.<br />
System Design Considerations and Operating Parameters<br />
To optimize force-feed lubrication system operation, <strong>Ariel</strong> uses the following general guidelines:<br />
1. Maintain lube ratios within prescribed limits and cycle times as low as possible<br />
(normally 10 sec minimum) to provide each point with lubrication as frequently as<br />
possible.<br />
2. Multiple pumps with manifolding are used to ensure that 150% of the normal lubrication<br />
rate can be provided during break-in.<br />
3. Pumps are not allowed to operate below 20% of full stroke, the point at which they<br />
become unreliable.<br />
4. In some applications, to optimize operation of the lubrication system, a single<br />
divider section is used to deliver lubrication to both a packing and a cylinder.<br />
5. In some applications, cross-porting of divider valves is used to deliver the proper<br />
proportion of lubricant to a given point.<br />
Force Feed Balance Valves<br />
Balance Valves may be used in high differential-pressure distribution-block<br />
applications to reduce system problems such as<br />
bypassing, no-flow switch errors or blown rupture discs. The<br />
force feed balance valve is shown in the Figure.<br />
Setting and Maintaining Balance Valves<br />
Balance valves cannot be set prior to operating the unit. Ensure<br />
that all fittings are tight and any known leaks have been fixed.<br />
Purge the force feed lube system with a high-pressure hand<br />
pump, using the same injection oil that is used in service, to re-<br />
FIGURE 4-12: FORCE FEED<br />
BALANCE VALVE<br />
move any trapped air or gas in the system. See Technical Manual Section 7 for pump illustration<br />
and part number. DO NOT USE ANY OTHER FLUIDS FOR PURGING!<br />
Start up the compressor and bring up to normal operating pressure. After the operating pressures<br />
have stabilized, adjust the cap on the top of the balance valve if necessary. Loosen the<br />
PAGE 4 - 50 7/09