XENOSEP®<br />

EPA<br />

1664A Std.<br />

Plus 14 g<br />

Solids<br />

SPE Systems for<br />

EPA Method 1664A<br />

The Easiest, Most<br />

Cost Effective Way to<br />

Increase Productivity<br />

“With Xenosep SPE<br />

Filters, we experienced a<br />

significant reduction in<br />

labor and solvent usage<br />

when compared to our old<br />

brand of SPE disks.”<br />

J. D. Waggoner, Managing Partner,<br />

Inovatia Laboratories<br />

93.4% HEM<br />

Recovery<br />

Filtration<br />

Complete in Less<br />

than 1 Minute<br />

Making the Difference in Separation Products


Step 1<br />

XENOSEP ®<br />

SPE Systems for<br />

EPA Method 1664A<br />

Step 3<br />

Step 2<br />

Extract Samples 5 Times<br />

Faster, Distill Samples 3 Times<br />

Faster, and Significantly<br />

Lower Cost Per Test...<br />

Step 1<br />

Extract 1 L Sample<br />

17 seconds is all it takes to filter a 40 mg/L* OPR and<br />

achieve 98% recovery. That’s 50 times faster than a<br />

typical single layer SPE filter with 89% recovery.<br />

In addition, triple layer Xenosep SPE Filters have<br />

5 times the filtration capacity already built-in for the<br />

MS, MSD, and hard-to-filter samples.<br />

*As required by EPA Method 1664A<br />

Three Simple Steps<br />

Increase Productivity,<br />

Saves Time and Money...<br />

Step 2<br />

Elute and Dry Extract<br />

Less filter clogging enables <strong>more</strong> efficient filter drying<br />

and eluting with less solvent. Xenosep sodium sulfate<br />

columns save time by eliminating off-line drying steps<br />

or repouring the extracted water sample back into the<br />

separatory funnel.<br />

Step 3<br />

Distill and Oven Dry Extract<br />

Less extraction solvent means faster distillation.<br />

Final hexane extracts distill to dryness in about 10<br />

minutes. Unique flat sided Xenosep flasks reduce<br />

oven drying times by 67% so you get QC tests<br />

in the dessicator 3 times faster than the other<br />

options below.<br />

Compare the Options<br />

Process Step Xenosep ® SPE Typical SPE Hexane LLE<br />

Extract-Elute-Dry 8.8 min. 26.5 min. 46.0 min.<br />

Distill-Oven Dry 21.0 min. 50.0 min. 60.0 min.<br />

Time to Dessicator 29.8 min. 76.5 min. 106.0 min.<br />

Estimated Labor/Batch of 20 4 hrs. 6 hrs. 8 hrs.<br />

Xenosep Labor Savings/Batch 2 hrs. 4 hrs.


The First SPE Filter and Glass<br />

Apparatus Specially Designed for<br />

Dirty Wastewater Samples<br />

Conditioning/Filtration Apparatus<br />

• Short wide funnel for easy access<br />

and effective glassware rinsing<br />

• Built-In space for optional prefilters,<br />

filter aids, and/or drying agent additions<br />

to “wet” solids<br />

• Secure coupler maximizes effective<br />

filtration area and prevents assembly<br />

misalignment<br />

• Teflon ® encapsulated O-ring seal<br />

eliminates solvent and vacuum leaks<br />

without extractables<br />

• Solid rimmed stainless steel support<br />

prevents analyte bypass<br />

• Flared collection tube for easy removal<br />

• Wider internal diameter stem maximizes<br />

filtration rates<br />

• Universal Ts 40/35 joint connects to<br />

elution apparatus or standard multi-place<br />

manifold, optimized to accept 30 mm OD<br />

vials or collection tubes<br />

• Easy to clean glassware minimizes breakage<br />

and fits standard washers


Integral Design Maximizes Filtration<br />

Efficiency, Simplifies Analyte Recovery,<br />

and Ensures Reproducible Results<br />

Elution/Cleaning Apparatus<br />

• Unique integral apparatus increases productivity<br />

and lowers cost per result<br />

• Disposable prepacked sodium sulfate cartridge<br />

maximizes recoveries, speed, and eliminates<br />

off-line transfers<br />

• Dedicated station for sample elution,<br />

drying and CIP (clean-in-place) glassware<br />

solvent rinsing<br />

• Universal TS 24/25 joint for collection into<br />

standard TS 24/40 flask<br />

• Flat sided flask gently evaporates extract<br />

to increase recoveries and lower MDLs<br />

Distillation/Evaporation Apparatus<br />

• Compact cross-over condenser design simplifies<br />

solvent recovery and provides analyst protection<br />

• Flat sided flask optimized to reduce<br />

distillation/evaporation times<br />

• N 2 inlet provided for safety and faster<br />

distillation/evaporation


Xenosep ® SPE Fast Throughput<br />

High Capacity Filters<br />

Unique Triple Layer Construction Offers Fastest<br />

Sample Throughput and Highest Filtration Capacity<br />

• No emulsions or Freon ® non-compliance<br />

• Assure legally defensible data<br />

• Achieve higher quality results<br />

• Reliable and consistent performance<br />

• Decrease sample turnaround time<br />

• Eliminate additional prefilter expense<br />

• Significantly reduce operating cost<br />

Three Filter Layers Trap Different Size<br />

Solids to Maximize Speed and<br />

Filtration Capacity<br />

Filtration Extraction Elution<br />

5-25 µm Prefilter<br />

1-5 µm Prefilter<br />

Adsorbent Layer<br />

Filter Dirty Samples 10 Times Faster<br />

Sample Filtered, (mL)<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

Xenosep ® SPE Filters 1 L<br />

in 38 Sec. (Recovery 93.4%)<br />

Sample:<br />

40 mg/L* EPA 1664A Std.<br />

Plus 14 g of Solids Added<br />

Typical SPE Filters 1 L in<br />

6.5 Min. (Recovery 79.9%)<br />

Cutaway views of how the triple layer Xenosep SPE Filter<br />

separates analytes from particulate and unwanted<br />

soluble interferences<br />

Green–3 µm Particulates<br />

Red–Oil and Grease Analytes<br />

Black–8 µm Particulates<br />

Blue–Soluble Interference<br />

Brown–30 µm Particulates<br />

• •<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10<br />

Time (Minutes)<br />

Temperature: 21°C, Vacuum: 15˝ Hg<br />

SPE Filters–47 mm Diameter<br />

Extra Thick Fluffy Layer Suspends<br />

Solids Filter Cake and Prevents<br />

Premature Clogging of Dirty Samples<br />

Why are 40 mg/L PAR Comparisons Important<br />

EPA Method 1664A requires the PAR concentration as<br />

follows: “The weight must be 40 ± 1 mg” (Section<br />

7.10.3 NOTE) and at least this amount are required for<br />

the QCS, OPR, MS, MSD, and IPR samples. (Sections<br />

9.8, 9.7, 9.6.1, 9.3.1, 9.2.2, 7.11 and 7.10) Although<br />

certain method modifications are allowed, a change in<br />

the PAR concentration is not expressly permitted and<br />

“shall be considered a major modification subject to<br />

application and approval of alternate test procedures<br />

under CFR 136.4 and 136.5.” (Sections 1.7 and 1.8)<br />

Why expose the defensibility of your data to<br />

unnecessary legal risk Use 40 mg/L QC samples and<br />

achieve higher quality results with Xenosep SPE Filters.<br />

Request your free samples today online at<br />

www.xenosep.com/contact.html.<br />

PAR (Precision and Recovery); QCS (Quality Control Sample); OPR (Ongoing<br />

Precision and Recovery); IPR (Initial Precision and Recovery); MS (Matrix Spike);<br />

MSD (Matrix Spike Duplicate)<br />

PAR Standard Filtered (mg)<br />

240<br />

200<br />

160<br />

120<br />

80<br />

40<br />

SPE Speed and Filtration Capacity<br />

40 mg/L* EPA 1664A PAR Standard<br />

Xenosep SPE Filters 1 L in<br />

17 Sec. (Recovery 97.6%)<br />

Typical SPE Filters 1 L in 19.2 minutes (Recovery 89.3%)<br />

0 2 4 6 8 10 12 14 16 18 20<br />

Time (Minutes)<br />

Temperature: 21°C, Vacuum: 15˝ Hg<br />

SPE Filters–47 mm Diameter<br />

Xenosep SPE Filters 5.5 L<br />

in 20 Min. (Recovery 95.5%)<br />

Xenosep SPE Filters Have FIVE<br />

Times Greater Filtration Capacity<br />

*As required by EPA Method 1664A<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

PAR Standard Filtered (L)


Ordering Information for Xenosep ® SPE Systems<br />

Xenosep SPE Systems for performing EPA Method 1664A<br />

are available in convenient Starter Kits for laboratories just<br />

starting out. Starter Kits include all components required to<br />

process one sample at a time. Additional components are<br />

available for scale up as required.<br />

Xenosep Manifold Kits are available for a three position<br />

manifold and include components necessary to process<br />

three samples at a time. If your laboratory has existing<br />

glassware or manifolds, please visit our web site at<br />

www.xenosep.com or call 1.866.936.6737 for assistance.<br />

Note: Lab stand and<br />

clamps not included<br />

Xenosep ® SPE Starter Kit<br />

Part No. Description<br />

26616 Starter Kit, 47 mm, 1 Place<br />

Part No. for Kit Components Included*<br />

Quantity<br />

26603; 26604; 26610; 26611; 26613; 26614; 26615; 26508;<br />

26514; 26515; 26516; 26517<br />

1 each<br />

26608 2 each<br />

26512 3 each<br />

26513 7 each<br />

*See Replacement Parts for description<br />

Additional Apparatus Assembly Kits<br />

Part No. Description Quantity<br />

26511 Distillation Kit, Complete<br />

26513; 26514; 26515 1 each<br />

26512 3 each<br />

26526 Flask Kit, Flat Sided, TS 24/25, 125 mL<br />

26513 12 each<br />

26600 SPE Filtration Assembly, 47 mm, Starter<br />

26603; 26604; 26610; 26611; 26613 1 each<br />

26608 2 each<br />

26601 SPE Filtration Assembly, 47 mm, Manifold<br />

26603; 26605; 26610; 26611; 26613 1 each<br />

26608 2 each<br />

26620 Consumables Kit, 24 Tests<br />

24547; 26520; 26524 24 each<br />

Consumables<br />

Part No. Description Quantity<br />

24547 SPE Filters, 1664A, 47 mm 48<br />

26520 Pipets, Transfer, Polyethylene, 15 mL 48<br />

26524 Column, Inline, Sodium Sulfate, 10 g 48<br />

26528 Fibers, Prefilter, 50 g 1<br />

26532 EPA 1664A Std., 1 x 100 mL, 4 mg/mL 1<br />

26533 EPA 1664A Std., 12 x 10 mL, 4 mg/mL 12<br />

©Copyright, Xenosep Technologies, 2006 Printed in USA<br />

Xenosep ® is a registered trademark of Xenosep Technologies LLC<br />

Freon ® , Teflon ® , and Viton ® are registered trademarks of DuPont<br />

Tygon ® is a registered trademark of Saint-Gobain Performance Plastics<br />

Note: Manifold sold separately<br />

Xenosep ® SPE Manifold Kit<br />

Part No. Description<br />

26618 Manifold Kit, 47 mm, 3 Place<br />

Part No. for Kit Components Included*<br />

Quantity<br />

26615; 26512; 26516; 26519 1 each<br />

26603; 26605; 26610; 26611; 26507; 26613 3 each<br />

26608 6 each<br />

*See Replacement Parts for description<br />

Replacement Parts and Components<br />

Part No. Description Quantity<br />

26507 Vials, Collection, 30 x 125 mm 1<br />

26508 Tube, Collection, 30 x 200 mm 1<br />

26512 Clamp, Polyoxymethylene Acetal, TS 24/25 1<br />

26513 Flask, Flat Sided Erlenmeyer, TS 24/25, 125 mL 1<br />

26514 Flask, Round Flat Bottom, TS 24/25, 125 mL 1<br />

26515 Condenser, Crossover w/#2HB 1<br />

26516 Eluter, Glass, w/#2HB 1<br />

26517 Stopcock, Glass, 120° 3 way, 4 mm ID 1<br />

26519 Stopcock Assembly, Manifold 1<br />

26523 Vent Assembly, Manifold 12<br />

26603 Funnel, 300 mL, 47 mm 1<br />

26604 Holder, Starter, 47 mm 1<br />

26605 Holder, Manifold, 47 mm 1<br />

26608 O-Rings, FEP-Viton ® , Coupler, 47 mm 1<br />

26610 Coupler, PTFE, 47 mm 1<br />

26611 Support, Stainless Steel, 47 mm 1<br />

26613 Clamp, Aluminum, 47 mm 1<br />

26614 Flask, TS 40/35, 1 L 1<br />

26615 Tubing, Tygon ® , 3/8˝ ID x 5/8˝ OD, 3´ 1<br />

26619 Manifold, Complete, Stainless Steel, 3 Place 1<br />

Making the Difference in<br />

Separation Products<br />

Xenosep Technologies LLC<br />

508 Main Street, Boonton, NJ 07005<br />

866.XENOSEP (866.936.6737) • 973.239.0247 • FAX: 973.239.4133<br />

E-mail: info@xenosep.com • www.xenosep.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!