24.01.2015 Views

PLC Programming

  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Project Options...<br />

Autodeclaration: If this option is activted , then after the input of a not-yet -declared variable a dialog<br />

box will appear in all editors with which this variable can be declared.<br />

Autoformat: If this option is activted, then CoDeSys executes automatic formatting in the IL editor<br />

and in the declaration editor. When you finish with a line, the following formatting is made: 1.Operators<br />

written in small letters are shown in capitals; 2. Tabs are inserted to that the columns are uniformly<br />

divided.<br />

List components: If this option is activated, then the Intellisense functionality wil be available to<br />

work as an input assistant. This means that if you insert a dot at a position where a identifier should<br />

be inserted, then a selection list will open, offering all global variables which are found in the project. If<br />

you insert the name of a function block instance, then you will get a selection list of all inputs and<br />

outputs of the instanced function block. The Intellisense function is available in editors, in the Watchand<br />

Receiptmanager, in visualizations and in the Sampling Trace.<br />

Declarations as tables: If this option is activated, then you can edit variables in a table instead of<br />

using the usual declaration editor. This table is sorted like a card box, where you find tabs for input<br />

variables, output variables local variables and in_out variables. For each variable there are edit fields<br />

to insert Name, Address, Type, Initial and Commment.<br />

Tab-Width: In the field Tab-Width in the category Editor of the Options dialog box you can determine<br />

the width of a tab as shown in the editors. The default setting is four characters, whereby the<br />

character width depends upon the font which is chosen.<br />

Font: By clicking on the button Font in the category Editor of the Options dialog box you can choose<br />

the font in all CoDeSys editors. The font size is the basic unit for all drawing operations. The choice of<br />

a larger font size thus enlarges the printout, even with each editor of CoDeSys.<br />

After you have entered the command, the font dialog box opens for choosing the font, style and font<br />

size.<br />

Dialog box for setting the font<br />

Options for the Desktop<br />

If you choose this category in the Options dialog box, then you get the dialog box shown below.<br />

Tool bar: The tool bar with the buttons for faster selection of menu commands becomes visible<br />

underneath the menu bar.<br />

Status bar: The status bar at the lower edge of the CoDeSys main window becomes visible.<br />

Online in Security mode: In Online mode with the commands 'Run', 'Stop', 'Reset' 'Toggle<br />

Breakpoint', 'Single cycle', 'Write values', 'Force values' and 'Release force', a dialog box appears with<br />

the confirmation request whether the command should really be executed. This option is saved with<br />

the project.<br />

4-6 CoDeSys V2.3