6 - The Resources<br />

'Extras' 'Show grid'<br />

With this command you can switch on and off the grid in the graphic window. When the grid is<br />

switched on, a check (ü) will appear next to the menu item.<br />

'Extras' 'Y Scaling'<br />

With this command you can change the preset Y scaling of a curve in the trace display. By<br />

doubleclicking on a curve you will also be given the dialog box 'Y-scaling'.<br />

As long as option Automatic is activated, the default scaling will be used, which depends on the type<br />

of the used variable. In case of enumeration variables the enumeration values will be displayed at the<br />

scale. In order to change the scaling, deactivate option 'Automatic' and enter the number of the<br />

respective curve (Channel) and the new maximum (maximum y scale) and the new minimum value<br />

(minimum y scale) on the y axis.<br />

The channel and the former value are preset.<br />

Dialog Box for Setting the Y Scale<br />

'Extras' 'Stretch'<br />

Symbol:<br />

With this command you can stretch (zoom) the values of the Sampling Trace that are shown. The<br />

beginning position is set with the horizontal picture adjustment bar. With repeated stretches that follow<br />

one-after-another, the trace section displayed in the window will increasingly shrink in size.<br />

This command is the counterpart to 'Extras' 'Compress'.<br />

'Extras' 'Compress'<br />

Symbol:<br />

With this command the values shown for the Sampling Trace are compressed; i.e., after this<br />

command you can view the progression of the trace variables within a larger time frame. A multiple<br />

execution of the command is possible.<br />

This command is the counterpart to 'Extras' 'Stretch'.<br />

6.9.2 'Extras' 'Save trace values'<br />

'Save Values'<br />

Use the commands of this menu to save traces (configuration + values) to files resp. to reload them<br />

from files to the project. Besids that a trace can be saved in a file in ASCII-format.<br />

Note: Regard the alternative way of storing and reloading traces by using the commands of menu 'Extras'<br />

'External Trace Configurations' (XML format, *.mon-Datei) !<br />

With this command you can save a Sampling Trace (values + configuration data). The dialog box for<br />

saving a file is opened. The file name receives the extension "*.trc".<br />

CoDeSys V2.3 6-47