a) Mark the values of the maximum axial and lateral movement for 1000 full load cycles, taken from the dimension table, onto the X- and Y-<br />

axis.<br />

maximum axial movement = ± 46 mm<br />

maximum lateral movement = ± 77 mm<br />

b) By connecting these corner points, the movement triangle is obtained (movement limiting line)<br />

c) Mark the requested lateral movement (if the movement distribution is asymmetrical, take the maximum lateral movement part). At the<br />

intersection with the movement limiting line, the maximum permissible axial movement of ± 22 mm can be determined.<br />

So the expansion joint type UFS 6-20, DN 200, allows simultaneous axial movement of ± 22 mm, in addition to the requested lateral movement<br />

of ± 40 mm.<br />

Calculation of the prerestraint<br />

Movement formula:<br />

H = movement = total movement [mm]<br />

Prerestraint formula:<br />

prerestraint<br />

<br />

H<br />

2<br />

H (t<br />

<br />

t<br />

max<br />

e<br />

t<br />

t<br />

min<br />

min<br />

)<br />

<br />

mm<br />

<br />

t min = minimum temperature [°C]<br />

t max = maximum temperature [°C]<br />

t e = installation temperature [°C]<br />

Example<br />

axial movement = ± 22 mm<br />

lateral movement = ± 40 mm<br />

t min = 0 °C<br />

t max = 120 °C<br />

t e = 20 °C<br />

44 44 (20 0)<br />

axial prerestraint = <br />

= 14,67 mm 14.7 mm<br />

2 120 0<br />

80 80 (20 0)<br />

lateral prerestraint = <br />

= 26,67 mm 26.7 mm<br />

2 120 0<br />