E11.11 TIER 1 – EMERGENCY CLOSURE SYSTEM CONDITION INDEX<br />

CALCULATIONS<br />

Enter the Emergency Closure Systems condition indicator scores from the tables above into the<br />

Emergency Closure Systems <strong>Assessment</strong> Summary Form at the end of this document. Multiply<br />

each indicator score by its respective Weighting Factor, and sum the total scores to arrive at the<br />

Tier 1 Emergency Closure System Condition Index.<br />

E11.12 TIER 1 – EMERGENCY CLOSURE SYSTEM DATA QUALITY INDICATOR<br />

The Emergency Closure Systems Data Quality Indicator reflects the quality of the inspection,<br />

test, and measurement results used to evaluate the condition of the emergency closure system<br />

under Tier 1. The more current and complete the results are, the higher the rating for this<br />

indicator. A condition assessment schedule appropriate for scoring the Data Quality Indicator is<br />

shown in Table 9. Alternatively, an organization’s recommended or standard practice for<br />

performing the emergency closure system tests and inspections may be substituted for the time<br />

intervals given in the table.<br />

Results are analyzed and applied to Table 9 to arrive at an appropriate Emergency Closure<br />

System Data Quality Indicator Score.<br />

Table 9 – Emergency Closure System Data Quality Indicator Scoring<br />

Data Quality<br />

Years Since Last Condition <strong>Assessment</strong><br />

Indicator Score<br />

< 8 years 10<br />

≥ 8 and < 17 years 7<br />

≥ 17 and < 25 years 4<br />

≥ 25 years 0<br />

Enter the Emergency Closure System Data Quality Indicator Score from Table 9 into the<br />

Emergency Closure System Condition <strong>Assessment</strong> Summary form at the end of this document.<br />