Error code Description Measure 2104 2000 2001 2002 2003 2004 2050 I/O error (W) occurred in the connection to the host device. I/O error (RW) occurred in the device. I/O error (SEL) occurred in the device. Memory related error occurred in the device. Logical error occurred in the device. Socket related error occurred in the device. Command error occurred in the device. • Check the connection of relay units (HUB, etc.) between host and this device and the UTP cable, and retry the delivery. • Check that the communication parameters (set values) are specified correctly in the device. If the device does not recover from this error by turning the power off and on, take the following measures. • Check if the communication condition and protocol meet the specifications of the computer. • Check if the connection cable is defective or is connected securely. • If the error is not removed, please notify your dealer or our service center of the displayed error message and error condition. ■PDL warning Description : This message appears if any problem exists in the data sent from the computer. Measure : Remove the cause of problem, and recreate the data correctly. For practical measures, see the table. Note ◆ The PDL warning appears on the Control Panel, but it disappears when the next operation is performed. Consequently, you may not know that the error occurred. ◆ It is recommended that the “ERROR MEMO” of “DRAWING PARAM.” in the setup menu be turned on, so that the error message is printed on the drawing. 14-28

▼When an error message appears (1) Plotter PDL W DATA xxxx xxxx: Error code Error code Printed error memo Description 0100 W FORMATERROR D-SCAN format is erroneous. 0201 W COMMAND ERROR 0202 W # OF PARAM. ERROR 0203 W PARAM._RANGE_ER R 0205 W UNDEFINED COMMAND 0207 W POLYGON_BFFR_ER R 0208 - (No error memo) 0209 W CHAR._OVERFLOW 0300 W PATTERN OVERFLO W 0301 W HATCH OVERFLOW 0303 W CHAR._OVERFLOW HP-GL or HP-GL/2 command not supported was received. The number of parameters of HP-GL or HP-GL/2 command is wrong. The plotting instruction that exceeds the range supported by HP-GL or HP-GL/2 command, or the plotting instruction that uses illegal characters was received. Character set instruction of HP-GL or HP-GL/2 command not supported was received. Polygon buffer overflow error occurred. Data is ignored, bacause there is no effective plotting data exists in HP-GL command. There is no empty area in memory for user registered characters of HP-GL (DL/UC command). There are too many pattern registrations in one drawing and the pattern memory overflows. There are too many hatch registrations in one drawing and the pattern memory overflows. There is no empty area in memory for user registered characters of HP-GL. Measure Analyzethedatadumpedtogether with the error message, and correct erroneous part at the computer side. Correct erroneous part at the computer side. Correct erroneous part at the computer side. (Polygon buffer upper limit: 106600 points) Check the computer side if effective plotting data is transferred. Correct so as to reduce the number of registrations or data by one character. Reduce the pattern registrations in one drawing. Reduce the hatch registrations in one drawing. Correct so as to reduce the number of registrations or data by one character. Chapter 14 Troubleshooting 14-29

▼When an error message appears<br />

(1) Plotter PDL<br />

W DATA xxxx<br />

xxxx: Error code<br />

Error<br />

code<br />

Printed error<br />

memo<br />

Description<br />

0100<br />

W FORMATERROR<br />

D-SCAN format is erroneous.<br />

0201<br />

W COMMAND ERROR<br />

0202<br />

W # OF PARAM. ERROR<br />

0203<br />

W PARAM._RANGE_ER R<br />

0205<br />

W UNDEFINED<br />

COMMAND<br />

0207<br />

W POLYGON_BFFR_ER R<br />

0208<br />

- (No error memo)<br />

0209<br />

W CHAR._OVERFLOW<br />

0300<br />

W PATTERN OVERFLO W<br />

0301<br />

W HATCH OVERFLOW<br />

0303<br />

W CHAR._OVERFLOW<br />

HP-GL or HP-GL/2 command<br />

not supported was received.<br />

The number of parameters of<br />

HP-GL or HP-GL/2 command<br />

is wrong.<br />

The plotting instruction that<br />

exceeds the range supported by<br />

HP-GL or HP-GL/2 command, or<br />

the plotting instruction that uses<br />

illegal characters was received.<br />

Character set instruction of<br />

HP-GL or HP-GL/2 command<br />

not supported was received.<br />

Polygon buffer overflow error<br />

occurred.<br />

Data is ignored, bacause there<br />

is no effective plotting data<br />

exists in HP-GL command.<br />

There is no empty area in memory<br />

for user registered characters of<br />

HP-GL (DL/UC command).<br />

There are too many pattern<br />

registrations in one drawing and<br />

the pattern memory overflows.<br />

There are too many hatch<br />

registrations in one drawing and<br />

the pattern memory overflows.<br />

There is no empty area in<br />

memory for user registered<br />

characters of HP-GL.<br />

Measure<br />

Analyzethedatadumpedtogether<br />

with the error message, and<br />

correct erroneous part at the<br />

computer side.<br />

Correct erroneous part at the<br />

computer side.<br />

Correct erroneous part at the<br />

computer side. (Polygon buffer<br />

upper limit: 106600 points)<br />

Check the computer side if<br />

effective plotting data is<br />

transferred.<br />

Correct so as to reduce the<br />

number of registrations or data<br />

by one character.<br />

Reduce the pattern registrations<br />

in one drawing.<br />

Reduce the hatch registrations<br />

in one drawing.<br />

Correct so as to reduce the<br />

number of registrations or data<br />

by one character.<br />

Chapter 14 Troubleshooting<br />

14-29