W UN- INI T . NVRAM Description : This message appears if the nonvolatile memory (NVRAM) of the device is not initialized. Measure : The display of this warning message continues until the [Enter] key is pressed. After the [Enter] key is pressed, the NVRAM is initialized automatically and the display changes to the language setting specifically for the installing operation. 14-22

▼When an error message appears ■Communication warnings Description : A communication error message appears if any communication error occurs between the computer and the device. For a practical description, see the following table. Measure : If the device does not recover from this error by turning the power off and on, follow the guidelines described in the Measure column of the table. If the error is not removed, please notify your dealer or our service center of the displayed error message and error condition. Note ◆ A communication warning appears on the LCD, but it disappears when the next operation is performed. Consequently, you may not recognize that the error occurred. In such a case, retransmit the data to check if the communication warning is displayed on the LCD. (1) Ethernet interface xxxx: Error code W INTERFACE-LN xxxx Chapter 14 Troubleshooting Error code Description Measure 0101 Duplication of XPT port number 0212 Lack of internal memory 0220 to 022F 0250 to 025F 0260 to 026F 1000 to 4FFF 5000 to 7FFF Protocol data sent from the host is defective Host disconnects the communication forcibly while a connection is established Communication to the host failed while communication time out data is transferred Communication connection system error Communication system internal error Specify the parameter at the device side correctly. If the device does not recover from this error by turning the power off and on, take the following measures: - Check if the communication condition and protocol match the specifications of the computer. - Check if the connection cable is defective or is connected securely. - If the error is not removed, please notify your dealer or our service center of the displayed error message and error condition. 14-23

W UN- INI T .<br />

NVRAM<br />

Description : This message appears if the nonvolatile memory<br />

(NVRAM) of the device is not initialized.<br />

Measure : The display of this warning message continues until the<br />

[Enter] key is pressed.<br />

After the [Enter] key is pressed, the NVRAM is<br />

initialized automatically and the display changes to the<br />

language setting specifically for the installing operation.<br />

14-22