Setting items Ethernet parameter is an item in the system menu. After this menu is changed, the parameter is automatically saved and the system is reset. When there is a job standing for processing, you can only refer to this menu. If you only refer to the menu and do not change it, the system returns to the offline condition. Menu Third hierarchy item Fourth hierarchy item Fifth hierarchy item Parameter #PORT SELECT 1-10 >XLF-------- Choice input method N ote 1) (X, L, F, - ) #DHCP > DISABLE DISABLE ENABLE #IP ADDRESS >000.000.000.000 (Note 2, 6) I nput value #SUBNET MASK >000.000.000.000 (Note 6) I nput value #ROUTING TABLE #GATEWAY ADDR 01 >000.000.000.000 #NETWORK ADDR 01 >000.000.000.000 (Note 6) I nput value (Note 3, 6) I nput value #GATEWAY ADDR 02 >000.000.000.000 (Note 6) I nput value #NETWORK ADDR 02 >000.000.000.000 (Note 3, 6) I nput value #ROUTING TABLE 2 : : COMM.PARAM # ETHERNET #GATEWAY ADDR 10 >000.000.000.000 (Note 6) I nput value #NETWORK ADDR 10 >000.000.000.000 (Note 3, 6) I nput value #METRIC >064 Input value 1 to 255 #SETUP DETAILS #ETHERNET ADDR >0800832Annnn Reference only nnn: serial No. #CONNECTION SPD. >AUTO AUTO 100 10 #CONNECTION TYPE >AUTO AUTO FULL HALF #HTTP PORT >00080 Input value 0 to 65535 #PORT TIME OUT >30min OFF 5min 10min 15min 30min 12-2

▼Setting items Menu Third hierarchy item Fourth hierarchy item Fifth hierarchy item Parameter COMM.PARAM # ETHERNET #SETUP DETAILS #FTP DATA TYPE >ASCII/BIN #SNMP >OFF #SNMP VERSION >V1 #TRAP01 #TRAP02 #MANEGER >000.000.000.000 #ERROR >ON #JOB >OFF #IP ADDR >000.000.000.000 #PORT >ALL #MANAGER >000.000.000.000 #ERROR >ON #JOB >OFF #IP ADDR >000.000.000.000 #PORT >ALL Note 1) Up to 10 ports including XPT, LPD, FTP can be specified. The initial value is 1 port for each protocol.(XLF – – – – – – –) Setting example: # PORT SELECT 1-10 >FFFXXXLLL_ ......In case of 3 ports for each protocol. Note 2) Same as the IP address specified in the installing operation. Note 3) Network address is indicated only when the "Gateway address" is specified. Note 4) To be displayed only when the "TRAPnn job" is set to ON (IP address). Note 5) To be displayed only when the "TRAPnn job" is set to ON (PORT). Note 6) Not to be displayed when "DHCP" is set to enable. ASCII/BIN BIN OFF ON V1 V2 Choice input method ON OFF OFF ON (IP ADDRESS) ON (PORT) C (Note 4) hoice input method (Note 5) A LL PORT01 ⋅ PORT10 Choice input method ON OFF OFF ON (IP ADDRESS) ON (PORT) C (Note 4) hoice input method (Note 5) A LL PORT01 ⋅ PORT10 Chapter 12 Ethernet parameter "ETHERNET" 12-3

Setting items<br />

Ethernet parameter is an item in the system menu. After this menu is<br />

changed, the parameter is automatically saved and the system is reset.<br />

When there is a job standing for processing, you can only refer to this<br />

menu.<br />

If you only refer to the menu and do not change it, the system returns to<br />

the offline condition.<br />

Menu<br />

Third hierarchy item<br />

Fourth hierarchy item<br />

Fifth hierarchy item<br />

Parameter<br />

#PORT SELECT 1-10<br />

>XLF--------<br />

Choice input method<br />

N ote 1)<br />

(X, L, F, - )<br />

#DHCP<br />

> DISABLE<br />

DISABLE<br />

ENABLE<br />

#IP ADDRESS<br />

>000.000.000.000<br />

(Note 2, 6)<br />

I nput value<br />

#SUBNET MASK<br />

>000.000.000.000<br />

(Note 6)<br />

I nput value<br />

#ROUTING TABLE<br />

#GATEWAY ADDR 01<br />

>000.000.000.000<br />

#NETWORK ADDR 01<br />

>000.000.000.000<br />

(Note 6)<br />

I nput value<br />

(Note 3, 6)<br />

I nput value<br />

#GATEWAY ADDR 02<br />

>000.000.000.000<br />

(Note 6)<br />

I nput value<br />

#NETWORK ADDR 02<br />

>000.000.000.000<br />

(Note 3, 6)<br />

I nput value<br />

#ROUTING TABLE 2<br />

:<br />

:<br />

COMM.PARAM<br />

# ETHERNET<br />

#GATEWAY ADDR 10<br />

>000.000.000.000<br />

(Note 6)<br />

I nput value<br />

#NETWORK ADDR 10<br />

>000.000.000.000<br />

(Note 3, 6)<br />

I nput value<br />

#METRIC<br />

>064<br />

Input value<br />

1 to 255<br />

#SETUP DETAILS<br />

#ETHERNET ADDR<br />

>0800832Annnn<br />

Reference only<br />

nnn: serial No.<br />

#CONNECTION SPD.<br />

>AUTO<br />

AUTO<br />

100<br />

10<br />

#CONNECTION TYPE<br />

>AUTO<br />

AUTO<br />

FULL<br />

HALF<br />

#HTTP PORT<br />

>00080<br />

Input value<br />

0 to 65535<br />

#PORT TIME OUT<br />

>30min<br />

OFF<br />

5min<br />

10min<br />

15min<br />

30min<br />

12-2