▼Setting items<br />

■PARALLEL<br />

Specifies the parallel interface for communication.<br />

Only when the parallel interface installed is displayed.<br />

●TIMING MODE<br />

Specifies the communication conditions (signal timing) for the parallel<br />

interface.<br />

: Default value<br />

NORMAL/FAST/SLOW<br />

Chapter 11 "SYSTEM" menu<br />

When the NORMAL, FAST or SLOW parameter is selected, fixed<br />

values listed in the table below are automatically specified.<br />

Initial value of communication parameter (parallel)<br />

Item<br />

STROBE timing<br />

ACK on-time<br />

ACK pulse<br />

BUSY off<br />

length<br />

timing<br />

Fast<br />

mode<br />

Fall<br />

edge<br />

Normal<br />

mode<br />

Fall<br />

edge<br />

Slow mode<br />

Fall edge<br />

900<br />

nsec<br />

2 . 4 µ sec<br />

3 . 6 µ sec<br />

900<br />

nsec<br />

2 . 4 µ sec<br />

3 µ sec<br />

ACK rise edge<br />

ACK rise edge<br />

ACK rise edge<br />

●TIMEOUT (100msec.)<br />

Specifies the time at which the data reception is considered to have been<br />

completed after the data transmission is discontinued (unit: 100 msec).<br />

<br />

1 to 18000 Default value: 300<br />

11-5