<strong>Descaling</strong> <strong>ValVes</strong><br />

Pump Minimum Flow Control Valves (Without Power Operator/Automatic Recirculation Valve)<br />

developed for high pressure centrifugal pump protection. Popular applications<br />

include boiler feed water, petroleum, and steel mill hot strip descale water.<br />

Feature<br />

• Positive fail open bypass.<br />

• integral pulsation damper.<br />

• Forged steel body.<br />

• Design does not utilize a pilot valve or tube.<br />

• start-up bypass inserts available due to<br />

start-up debris.<br />

• maxi-Flow protection available.<br />

Minimum Flow Control<br />

With Power Operator<br />

restriction<br />

Office<br />

control Valve<br />

Or gate Valve<br />

Minimum Flow Control<br />

With Auto Recirc. Valve<br />

automatic<br />

recirculation<br />

Valve<br />

control Valve<br />

Or gate Valve<br />

Pump<br />

Back Press.<br />

Valve<br />

By-Pass line<br />

Pump<br />

reservoir<br />

reservoir<br />

it provides economical and reliable protection for low and reverse flow.<br />

By combining the functions of main line check valve, flow sensing, bypass flow<br />

control, bypass pressure reduction, pulsation dampener, and bypass line check<br />

valve, the valve eliminates at least seven components necessary with a conventional<br />

system. The valve operates without air or electric power and is easily installed<br />

with three connections.<br />

the valve is installed on the pump discharge, just as an ordinary check valve<br />

would be.<br />

Upon pump start-up, and without process demand, the bypass is completely open,<br />

recirculating the necessary minimum flow. Once process demand starts, the<br />

spring loaded disc is lifted and held in position by flow demand. Until main flow<br />

demand exceeds recommended minimum flow, the valve will modulated. as the<br />

main flow demand increases beyond recommended minimum flow, the bypass will<br />

close and all flow will go to the process.<br />

BeneFit<br />

• Positive pump protection.<br />

• smooth operation.<br />

• superior pressure containing integrity.<br />

• less sensitive to debris and operation.<br />

• cycle is not as harsh which can lead to system instability.<br />

• avoids possible damage to bypass trim.<br />

• Unique feature to prevent pump run-out.<br />

• long term proven design...Your operation is not a test lab.<br />

P<br />

the minimum flow control valve(automatic recirculation valve) of descaling pump is designed, manufactured and qualified by based on custom designed Product.<br />

r<br />

B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!