20.01.2015 Views

MetaXpress® Image Acquisition and Analysis Software Version 3.1

MetaXpress® Image Acquisition and Analysis Software Version 3.1

MetaXpress® Image Acquisition and Analysis Software Version 3.1

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong><br />

<strong>Analysis</strong> <strong>Software</strong> <strong>Version</strong> <strong>3.1</strong><br />

For <strong>Image</strong>Xpress ® Micro <strong>and</strong> <strong>Image</strong>Xpress ® Ultra<br />

Instrument Workstations<br />

Upgrade Guide<br />

5001659 Rev. B<br />

June 2010


This document is provided to customers who have purchased Molecular Devices, Inc.<br />

(“Molecular Devices”) equipment, software, reagents, <strong>and</strong> consumables to use in the<br />

operation of such Molecular Devices equipment, software, reagents, <strong>and</strong><br />

consumables. This document is copyright protected <strong>and</strong> any reproduction of this<br />

document, in whole or any part, is strictly prohibited, except as Molecular Devices<br />

may authorize in writing.<br />

Equipment, software, reagents, <strong>and</strong> consumables that may be described in this<br />

document are protected under one or more patents filed in the United States,<br />

Canada, <strong>and</strong> other countries. Additional patents are pending.<br />

<strong>Software</strong> that may be described in this document is furnished under a license<br />

agreement. It is against the law to copy, modify, or distribute the software on any<br />

medium, except as specifically allowed in the license agreement. Furthermore, the<br />

license agreement may prohibit the software from being disassembled, reverse<br />

engineered, or decompiled for any purpose.<br />

Portions of this document may make reference to other manufacturers <strong>and</strong>/or their<br />

products, which may contain parts whose names are registered as trademarks <strong>and</strong>/or<br />

function as trademarks of their respective owners. Any such usage is intended only<br />

to designate those manufacturers' products as supplied by Molecular Devices for<br />

incorporation into its equipment <strong>and</strong> does not imply any right <strong>and</strong>/or license to use<br />

or permit others to use such manufacturers' <strong>and</strong>/or their product names as<br />

trademarks.<br />

Molecular Devices makes no warranties or representations as to the fitness of this<br />

equipment for any particular purpose <strong>and</strong> assumes no responsibility or contingent<br />

liability, including indirect or consequential damages, for any use to which the<br />

purchaser may put the equipment described herein, or for any adverse circumstances<br />

arising therefrom.<br />

For research use only. Not for use in diagnostic procedures.<br />

The MDCStore SDK <strong>and</strong> associated documentation are copyrighted <strong>and</strong> property of<br />

Molecular Devices, Inc. Use of the MDCStore API (Application Programming<br />

Interface) <strong>and</strong> acceptance of the associated documentation is prohibited without the<br />

express written consent of Molecular Devices, Inc., which consent shall limit the scope<br />

of use of the MDCStore technology, shall be personal to the licensed user, <strong>and</strong> shall<br />

be non-transferable.<br />

ACUITYXPRESS, ADAPTIVE ACQUISITION, MDCSTORE, <strong>and</strong> MDCSTORETOOLS are<br />

trademarks <strong>and</strong> METAXPRESS, METAMORPH, META IMAGING SERIES, TRANSFLUOR,<br />

<strong>and</strong> IMAGEXPRESS are registered trademarks of Molecular Devices, Inc. These<br />

trademarks may not be used in any type of promotion or advertising without the<br />

prior written permission of Molecular Devices, Inc.<br />

Equipment built by Molecular Devices, Inc.<br />

1311 Orleans Drive, Sunnyvale, California, United States of America 94089.<br />

Molecular Devices, Inc. is ISO 9001 registered.<br />

© 2010 Molecular Devices, Inc.<br />

All rights reserved.<br />

Printed in the USA.


Contentsents<br />

Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />

Suggested Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Install the MetaXpress ® <strong>Software</strong> . . . . . . . . . . . . . . . . . . 5<br />

Install the Latest Update of the MetaXpress ® <strong>Software</strong> 14<br />

Install <strong>Version</strong> 9 of the USB Driver . . . . . . . . . . . . . . . . 21<br />

Configure the Objectives . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

Check for Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

5001659 B 1


2 5001659 B


Upgrading the MetaXpress ® <strong>Software</strong><br />

Before You Begin<br />

This guide provides instructions on how to upgrade the MetaXpress ®<br />

software from version 2 or version 3.0 to version <strong>3.1</strong> on <strong>Image</strong>Xpress ®<br />

Micro <strong>and</strong> <strong>Image</strong>Xpress ® Ultra instrument workstations.<br />

To see a list of the features of version <strong>3.1</strong> of the MetaXpress software,<br />

read the release notes on<br />

www.meta.moleculardevices.com/mxupdates.<br />

To view a presentation on the new MDCStoreTools TM application <strong>and</strong> the<br />

new Laser Autofocus wizard included with version <strong>3.1</strong> of the<br />

MetaXpress software, go to https://moldevents.webex.com. On the<br />

web site, click “High-Content Cellular Imaging” <strong>and</strong> then select the<br />

webinar “New Laser Autofocus Wizard <strong>and</strong> Data Management Tools with<br />

MetaXpress <strong>3.1</strong>”.<br />

Before upgrading to version <strong>3.1</strong> of the MetaXpress software, perform<br />

the following tasks:<br />

• Read the MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong><br />

Installation Guide for <strong>Version</strong> <strong>3.1</strong>, available on the MetaXpress<br />

<strong>3.1</strong> software installation CD.<br />

• Make sure you are logged in as Administrator on the instrument<br />

workstation.<br />

• Make sure the C: drive has at least 1 GB of available space.<br />

• For <strong>Image</strong>Xpress Ultra systems, delete all files starting with<br />

“FS_” in the C:\Documents <strong>and</strong> Settings\window login<br />

account\Local Settings\Temp folder. Earlier versions of the<br />

MetaXpress software did not delete these files, which are<br />

created when images are larger than 10 MB. <strong>Version</strong> <strong>3.1</strong> of the<br />

software deletes these temporary files appropriately.<br />

5001659 B 3


Upgrading the MetaXpress ® <strong>Software</strong><br />

Suggested Workflow<br />

Upgrading to version <strong>3.1</strong> of the MetaXpress ® software involves several<br />

steps, most of which can be performed using the MetaXpress <strong>3.1</strong><br />

software installation CD. The following table lists the tasks required in<br />

the order they should be performed.<br />

Task<br />

Install version <strong>3.1</strong> of the MetaXpress ®<br />

software on the instrument workstation.<br />

Download <strong>and</strong> install the latest update for<br />

version <strong>3.1</strong> of the MetaXpress software.<br />

Install version 9 of the USB driver.<br />

Configure the numerical apertures <strong>and</strong><br />

working distances of the objectives.<br />

Update the MDCStore TM database to version<br />

2.2.<br />

Instructions<br />

See Install the MetaXpress®<br />

<strong>Software</strong> on page 5<br />

See Install the Latest Update<br />

of the MetaXpress® <strong>Software</strong><br />

on page 14<br />

See Install <strong>Version</strong> 9 of the<br />

USB Driver on page 21<br />

See Configure the Numerical<br />

Apertures <strong>and</strong> Working<br />

Distances of Objectives on<br />

page 24<br />

See the MDCStore TM 2.2<br />

Database Schema Installation<br />

<strong>and</strong> Update Guide*<br />

Install the MDCStoreTools TM application. See the MDCStoreTools TM 1.1<br />

User Guide*<br />

Create a user account with Administrator<br />

privileges on the MDCStore database schema.<br />

See the MDCStoreTools TM 1.1<br />

User Guide*<br />

*These manuals are included on the MetaXpress <strong>3.1</strong> software<br />

installation CD.<br />

Note: <strong>Version</strong> <strong>3.1</strong> of the MetaXpress software will work with version<br />

2.0 of the MDCStore TM database. However, to use the MDCStoreTools TM<br />

applications, you must upgrade the MDCStore database to version 2.2.<br />

4 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

Install the MetaXpress ® <strong>Software</strong><br />

CAUTION! Molecular Devices, Inc. assumes no responsibility for any<br />

damage to existing user data that may occur due to network problems,<br />

power failure, unexpected termination during the update process, user<br />

customization of an existing MDCStore TM database, <strong>and</strong> so on. You<br />

must fully back up your existing database before beginning an<br />

installation or upgrade procedure.<br />

Note: The 64-bit version of the MetaXpress ® <strong>3.1</strong> software is for offline<br />

use only.<br />

To install the MetaXpress software<br />

1. Insert the MetaXpress <strong>3.1</strong> software installation CD into the<br />

computer’s CD-ROM drive. If the installation screen does not<br />

appear, go to the CD folder <strong>and</strong> double-click autorun.exe.<br />

Note: If you do not have the MetaXpress <strong>3.1</strong> software<br />

installation CD, contact Molecular Devices, Inc. Support at<br />

www.moleculardevices.com/support. You will need to provide<br />

your System ID.<br />

The MetaXpress software installation screen appears.<br />

5001659 B 5


Upgrading the MetaXpress ® <strong>Software</strong><br />

2. Click Install MetaXpress <strong>3.1</strong>: 32-bit.<br />

A message appears asking you to confirm the installation.<br />

6 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

3. Click Yes.<br />

The MetaXpress <strong>3.1</strong> software installation wizard appears.<br />

4. Click Next.<br />

The software license agreement appears.<br />

5. Select I Accept all terms of the preceding License <strong>and</strong> then<br />

click Next.<br />

The Sentinel Security Components page of the installation<br />

wizard appears.<br />

6. Click Next.<br />

7. If the installation wizard does not detect an earlier version of the<br />

MetaXpress software on the instrument workstation, skip to<br />

Step 10. If an earlier version of the software is detected on the<br />

instrument workstation, the message below appears.<br />

5001659 B 7


Upgrading the MetaXpress ® <strong>Software</strong><br />

8. Select Copy the settings from this folder into a new<br />

destination folder <strong>and</strong> then click OK.<br />

Note: The installation wizard uses the settings from the copy of<br />

the MetaXpress software that was most recently open. If you<br />

want to install the MetaXpress software using the settings from<br />

a different copy of the software, close the installation wizard,<br />

open the other copy of the MetaXpress software <strong>and</strong> then close<br />

it, <strong>and</strong> then start the installation again from the beginning.<br />

8 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The Browse for Folder dialog box appears.<br />

9. Create a folder for the new copy of the MetaXpress software,<br />

<strong>and</strong> click OK.<br />

The Destination Folder page of the installation wizard appears.<br />

5001659 B 9


Upgrading the MetaXpress ® <strong>Software</strong><br />

10. Make sure the C: drive has enough space available as indicated<br />

in the Disk Space Limits section of the dialog box, change the<br />

destination folder if needed, <strong>and</strong> then select Next.<br />

The Program Group Selection page of the installation wizard<br />

appears.<br />

11. Change the name of the program group if needed, <strong>and</strong> click<br />

Next.<br />

10 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The Hardware Key Confirmation page of the installation wizard<br />

appears.<br />

12. Make sure the USB key for the MetaXpress software is inserted<br />

into the instrument workstation, select Use Local Key <strong>and</strong> then<br />

click Read System ID from Key.<br />

The installation wizard displays your System ID in the System<br />

ID field.<br />

13. Click Next.<br />

5001659 B 11


Upgrading the MetaXpress ® <strong>Software</strong><br />

The User Information <strong>and</strong> Codes page of the installation wizard<br />

appears.<br />

14. Enter the codes using one of the following methods:<br />

• If the instrument workstation is connected to the internet, click Using<br />

the Internet. The installation wizard retrieves the codes <strong>and</strong> displays<br />

them in the appropriate fields.<br />

• If the codes are on a disk, insert the disk <strong>and</strong> click From a Disk. The<br />

installation wizard copies the codes from the disk to the appropriate<br />

fields.<br />

• If the instrument workstation is not connected to the internet, click<br />

Manually <strong>and</strong> type the registration <strong>and</strong> authorization codes in the<br />

appropriate fields. You can find the codes on the letter that<br />

accompanied your order. Or, you can go to<br />

www.meta.moleculardevices.com/authorize/ to find the codes (you<br />

must provide your System ID on the web page).<br />

15. Click Next.<br />

16. Click Install.<br />

12 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The installation wizard installs version <strong>3.1</strong> of the MetaXpress<br />

software <strong>and</strong> then opens the Meta Imaging Series Administrator<br />

software.<br />

17. To create a folder on the desktop, click Create Icons.<br />

18. Click OK.<br />

The Installation Complete page of the installation wizard<br />

appears.<br />

19. Click Finish.<br />

5001659 B 13


Upgrading the MetaXpress ® <strong>Software</strong><br />

Install the Latest Update of the MetaXpress ® <strong>Software</strong><br />

Updates for the MetaXpress ® software are available for download on the<br />

Molecular Devices web site, as described below. If you are unable to<br />

download the update, please send an email to Support using the web<br />

site www.moleculardevices.com/support or call 1-800-635-5577 <strong>and</strong><br />

request that the latest update be sent to you. You will be asked for your<br />

System ID <strong>and</strong> the version of the software that you are requesting.<br />

To install an update of the MetaXpress software<br />

1. Go to www.meta.moleculardevices.com/mxupdates.<br />

2. Enter your System ID <strong>and</strong> click Log In. Your System ID is on<br />

your USB key <strong>and</strong> in the letter that accompanied your order.<br />

The web page that appears lists the available updates for the<br />

MetaXpress software.<br />

3. Select the latest update.<br />

The Update page for the update that you selected appears. For<br />

example:<br />

4. Click on the link for the 32-bit version to download the update<br />

file.<br />

5. When the license agreement appears, click I ACCEPT THE<br />

TERMS IN THIS AGREEMENT.<br />

14 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

A yellow bar appears indicating that the site is blocked from<br />

downloading.<br />

6. Click the yellow bar <strong>and</strong>, in the menu that appears, select<br />

Download File.<br />

The File Download dialog box appears.<br />

7. Click Save, choose a location on your hard drive for the update<br />

file in the Save As dialog box <strong>and</strong> then click Save again.<br />

Note: You can save the update file to a USB flash drive or DVD,<br />

which is especially useful if you are updating the MetaXpress<br />

software on more than one instrument workstation.<br />

CAUTION! Do not attempt to unzip the update file. The Meta Imaging<br />

Series ® Updater unzips the file during the update process.<br />

5001659 B 15


Upgrading the MetaXpress ® <strong>Software</strong><br />

8. From the Windows Start menu, select Programs>Meta<br />

Imaging Series>Meta Imaging Series Updater.<br />

The Meta Imaging Series Updater opens.<br />

9. Click Next.<br />

The Select Patch File page of the Meta Imaging Series Updater<br />

appears.<br />

10. Select the ellipsis (...) button.<br />

16 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The Open dialog box appears. For example:<br />

11. Navigate to the update file, select it, <strong>and</strong> then click Open.<br />

The Select Patch File page appears, displaying the path name of<br />

the update file that you selected.<br />

12. Click Next.<br />

5001659 B 17


Upgrading the MetaXpress ® <strong>Software</strong><br />

The Hardware Key Confirmation page of the Meta Imaging<br />

Series Updater appears.<br />

13. Make sure the USB key for the MetaXpress software is inserted<br />

into the instrument workstation, select Use Local Key <strong>and</strong> then<br />

click Read System ID from Key.<br />

The Meta Imaging Series Updater displays your System ID in<br />

the System ID field.<br />

14. Click Next.<br />

18 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The User Information <strong>and</strong> Codes page of the Meta Imaging<br />

Series Updater appears.<br />

15. Enter the codes using one of the following methods:<br />

• If the instrument workstation is connected to the internet, click Using<br />

the Internet. The Updater retrieves the codes <strong>and</strong> displays them in<br />

the appropriate fields.<br />

• If the codes are on a disk, insert the disk <strong>and</strong> click From a Disk. The<br />

Updater copies the codes from the disk to the appropriate fields.<br />

• If the instrument workstation is not connected to the internet, click<br />

Manually <strong>and</strong> type the registration <strong>and</strong> authorization codes in the<br />

appropriate fields. You can find the codes on the letter that<br />

accompanied the order. Or, you can go to<br />

www.meta.moleculardevices.com/authorize/ to find the codes (you will<br />

be asked to enter your System ID).<br />

16. Click Next.<br />

The Ready to Proceed page of the Meta Imaging Series Updater<br />

appears.<br />

17. Click Update.<br />

5001659 B 19


Upgrading the MetaXpress ® <strong>Software</strong><br />

When the installation is complete, the following page appears:<br />

18. Click Finish.<br />

The Meta Imaging Series Updater opens the Meta Imaging<br />

Series Administrator software.<br />

19. Click OK.<br />

20 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

Install <strong>Version</strong> 9 of the USB Driver<br />

You must update the USB driver on all instrument workstations. If you<br />

do not update the driver, the <strong>Image</strong>Xpress ® Micro <strong>and</strong> <strong>Image</strong>Xpress ®<br />

Ultra systems will not operate properly.<br />

Note: You do not need to install the driver on computers that are not<br />

used for acquisition.<br />

To update the driver<br />

1. Make sure you are logged in as Administrator on the instrument<br />

workstation.<br />

2. Insert the MetaXpress ® <strong>3.1</strong> software installation CD into the<br />

computer’s CD-ROM drive. If the installation screen does not<br />

appear, go to the CD folder <strong>and</strong> double-click autorun.exe.<br />

5001659 B 21


Upgrading the MetaXpress ® <strong>Software</strong><br />

The MetaXpress installation screen appears.<br />

3. Click Install IXM/IXU USB Driver V9: 32 bit.<br />

A message appears asking you to confirm the installation.<br />

4. Click Yes.<br />

22 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The WinZip Self-Extrator dialog box appears.<br />

5. Click Setup.<br />

The following page appears.<br />

6. If the installation wizard detected an earlier version of the driver<br />

on the computer, select Repair WinDriverMDC.<br />

7. Click Finish.<br />

8. When the Installation Complete page appears, click Close.<br />

5001659 B 23


Upgrading the MetaXpress ® <strong>Software</strong><br />

Configure the Numerical Apertures <strong>and</strong> Working<br />

Distances of Objectives<br />

To configure the objectives<br />

1. From the Windows Start menu, select Programs>Meta<br />

Imaging Series>Meta Imaging Series Administrator.<br />

The Meta Imaging Series ® Administrator appears.<br />

2. In the List of Groups, select the Group Name for version <strong>3.1</strong> of<br />

the MetaXpress ® software, <strong>and</strong> then click Configure<br />

Hardware.<br />

The Configure Hardware dialog box appears.<br />

24 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

3. In the Hardware Settings section, select the appropriate<br />

hardware configuration (for example, “IXM” or “IXU”), <strong>and</strong> then<br />

click Configure <strong>Acquisition</strong>.<br />

Note: If multiple hardware configurations exist (for example,<br />

multiple objective configurations or filter cube configurations),<br />

perform Steps 3-11 for each configuration.<br />

The Configure <strong>Acquisition</strong> dialog box appears.<br />

4. For <strong>Image</strong>Xpress ® Ultra systems, ensure that “<strong>Image</strong>Xpress<br />

Ultra” is listed in the Installed Drivers section of the dialog box.<br />

5. For <strong>Image</strong>Xpress ® Micro systems, ensure that “Photometrics” is<br />

listed in the Installed Drivers section of the dialog box.<br />

5001659 B 25


Upgrading the MetaXpress ® <strong>Software</strong><br />

6. Click OK.<br />

The Configure Hardware dialog box appears.<br />

7. In the Hardware Settings section, select the appropriate<br />

hardware configuration (for example, “IXU” or “IXM”), <strong>and</strong> then<br />

click Configure Devices.<br />

26 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

The User Settings for the hardware configuration dialog box<br />

appears. For example:<br />

8. In the Claimed Devices section, select the objective (for<br />

example, “<strong>Image</strong>Xpress Micro Objective” or “<strong>Image</strong>Xpress Ultra<br />

Objective”), <strong>and</strong> then click Settings.<br />

5001659 B 27


Upgrading the MetaXpress ® <strong>Software</strong><br />

The settings for the objective appear. For example:<br />

Using the following table, verify the numerical aperture <strong>and</strong> the<br />

working distance of each objective. Also, verify that the type of<br />

media is correct; if you are using oil or water, be sure to enter<br />

an appropriate refraction index.<br />

Note: If the working distance of an objective is a range of<br />

numbers (for example, the 20x ELWD objective), use the<br />

smallest number.<br />

28 5001659 B


MetaXpress ® <strong>Image</strong> <strong>Acquisition</strong> <strong>and</strong> <strong>Analysis</strong> <strong>Software</strong> Upgrade Guide<br />

Objective Magnification <strong>and</strong> Type<br />

* Recommended basic configuration<br />

** Common objectives<br />

Numerical<br />

Aperture<br />

1x Plan Achromat 0.04 3.2<br />

Working<br />

Distance<br />

(mm)<br />

4x S Fluor* 0.20 15.5<br />

4x Plan Apo** 0.20 15.7<br />

4x Plan Fluor DL 0.13 16.2<br />

10x Plan Fluor* 0.30 16<br />

10x S Fluor** 0.50 1.2<br />

10x Plan Fluor DLL 0.30 16<br />

10x Plan Fluor DL 0.30 15.2<br />

20x Plan Fluor ELWD cc 0-2mm* 0.45 8.1 - 7.0<br />

20x S Fluor** 0.75 1<br />

20x Plan Apo 0.75 1<br />

20x Plan Fluor DLL 0.50 2.1<br />

20x Plan Fluor ELWD DM cc 0-2mm 0.45 8.1 - 7.0<br />

40x Plan Fluor ELWD cc 0-2mm* 0.60 3.7 - 2.7<br />

40x Plan Apo cc 0.11 - 0.23 mm** 0.95 0.14<br />

40x S Fluor cc 0.11 - 0.23 mm** 0.90 0.3<br />

40x Plan Fluor Oil 1.30 0.2<br />

40x Plan Fluor DLL 0.75 0.72<br />

40x Plan Fluor ELWD DM cc 0-2 mm 0.60 3.7 - 2.7<br />

60x Plan Fluor ELWD cc 0.5 - 1.5 mm* 0.70 2.1 - 1.5<br />

60x Plan Fluor ** 0.85 0.3<br />

60x Plan Apo Oil 1.4 0.21<br />

60x Plan Fluor ELWD DLL cc 0.5 - 1.5 mm 0.70 2.1 - 1.5<br />

100x Plan Fluor cc 0.14 - 0.20 mm** 0.95 0.2<br />

100x Plan Fluor Oil 1.30 0.2<br />

5001659 B 29


Upgrading the MetaXpress ® <strong>Software</strong><br />

11. Click OK.<br />

Repeat Steps 3-11 for each configuration that exists.<br />

Check for Updates to the MetaXpress ® <strong>Software</strong> <strong>and</strong><br />

MDCStore Database<br />

Molecular Devices, Inc. recommends that you always use the latest<br />

available version of the MetaXpress ® software <strong>and</strong> MDCStore TM<br />

database. Periodically check the Molecular Devices web site,<br />

www.moleculardevices.com, for updates.<br />

30 5001659 B