B60 <strong>Busway</strong> Series<br />

B60 Plug-in <strong>Busway</strong> Series<br />

∂ Solid Copper Conductors<br />

Copper rather than aluminum<br />

is standard since copper is<br />

universally acknowledged as<br />

the best choice. 60 amps,<br />

300 and 600 volt ratings —<br />

2, 3 or 4 pole, 10,000 amp<br />

short circuit rating.<br />

∑ Continuous Mounting<br />

Channel<br />

Continuous mounting channel<br />

does not require exact spacing<br />

of supports. Hanger spacing<br />

up to 10 feet apart.<br />

∏Continuous Insulator<br />

The busway insulator is<br />

continuous and complies with<br />

the UL “Finger Safe Probe”<br />

standard. Other busbar<br />

systems place an insulator<br />

spacer at 12 to 18 inch<br />

intervals only. The B60<br />

<strong>Busway</strong> insulator and copper<br />

can also be supplied and<br />

inserted into the busway run<br />

in one piece.<br />

π Continuous Access Slot<br />

The continuous access slot<br />

allows the plug-in units to be<br />

attached to the busway at any<br />

location. They can be as close<br />

together or as far apart as<br />

desired.<br />

∫ Extruded Aluminum Housing<br />

Housing design combines<br />

strength, lightweight and clean<br />

appearance. The lightweight<br />

housing, about half the weight<br />

of steel-enclosed busway,<br />

makes 20 feet sections not<br />

only possible but practical. The<br />

aluminum enclosure is superior<br />

for 400 Hertz systems.<br />

❻ Ground Conductor<br />

The extruded aluminum<br />

housing is 100% capacity<br />

ground. There is no need to<br />

purchase and install special<br />

ground kits for the plug-in<br />

units. This is standard<br />

equipment, not an extra.<br />

❼ Plug-in Units<br />

Many types of plug-in units<br />

are available. These include<br />

the outlet box, fused,<br />

receptacle, terminal block,<br />

and circuit breaker plugs.<br />

They can be installed at any<br />

location along the busway run<br />

by simply inserting the plug<br />

head and rotating 90 degrees.<br />

➑Polarizing Lip<br />

The aluminum housing has a<br />

polarizing lip on one side of<br />

the access slot. This prevents<br />

“backwards” installation of<br />

plug-in units. All busway<br />

sections are installed with<br />

the polarizing lip on the<br />

same side.<br />

Voltage Drop:<br />

Length of busway for a one volt<br />

drop in the line to line voltage<br />

for a distributed load of 60<br />

amperes:<br />

Three phase, .8 PF 45 feet<br />

Single phase 40 feet<br />

Elevated Temperature<br />

Operation:<br />

3<br />

Amp Rating<br />

Ambient Temp. Multiplier<br />

40˚C / 104˚F 1.00<br />

45˚C / 113˚F 0.95<br />

50˚C / 122˚F 0.90<br />

55˚C / 131˚F 0.85<br />

60˚C / 140˚F 0.80<br />

65˚C / 149˚F<br />

70˚C / 158˚F 0.74<br />

For an authorized dealer or more information call toll free 800-333-3490 or 412-221-4400