9.3.4 Unsealed Footpath<br />

Where the specified works interfere with existing unsealed footpath areas, or where footpaths are<br />

nominated on the drawings as unsealed, the reinstatement / construction shall consist of 100 mm<br />

compacted thickness of PM 2/20 quarry rubble.<br />

The rubble shall be placed and compacted to a density of not less than 95% of the maximum<br />

modified dry density as set out in AS 1289 5.2.1 using approved compaction equipment. The rubble<br />

shall be finished to conform to the adjacent existing paths in level and appearance and to give<br />

satisfactory drainage properties.<br />

The Contractor shall ensure that completed works are not hazardous or threaten in any way the<br />

safety of the general public.<br />

9.3.5 Concrete Driveway<br />

Concrete footpaths shall be constructed to as detailed in the design drawings or to a minimum of<br />

100 mm granular sub-base with 125 mm thickness concrete base, and reinforced with SL72 steel<br />

fabric.<br />

Reinforcement shall be free from loose mill scale, loose rust, oil, grease and other non-metallic<br />

coatings which would reduce the bond to the concrete.<br />

Bar chairs, spacers and ties made of concrete, steel or plastic shall be used to support all<br />

reinforcement in its position within the tolerance specified in AS 3600 until the concrete has<br />

hardened.<br />

Reinforcement shall be located in the upper half of the driveway slab with a minimum 40 mm top<br />

cover, and terminated 75 mm from 50 mm from joints.<br />

9.3.5.1 Concrete Driveway Joints<br />

Expansion joints shall be 10 mm wide provided at minimum 12 m intervals. Expansion joints shall<br />

be provided with a full depth pre-moulded expansion joint filler, (bitumen impregnated fibre board or<br />

similar).<br />

In areas where new concrete is to be placed against and existing construction joint, the surface of<br />

the hardened concrete shall be thoroughly roughened and cleaned to remove any loose material,<br />

debris and laitance.<br />

9.3.6 Grassing<br />

Following filling, spreading and levelling of topsoil, all exposed batter slopes, excavated and filled<br />

areas shall be reseeded.<br />

Fertiliser shall be applied to the areas to be grassed at the rate of 30 grams of 2:1 superphosphate<br />

and sulphate of ammonia or other approved fertiliser per square metre. The area shall then be<br />

raked, seed spread and lightly raked again.<br />

A seed mix containing couch and perennial rye grasses or an approved alternative mix, shall be<br />

spread at a rate of 30 grams per square metre and watered to ensure germination and growth during<br />

the establishment period.<br />

As an alternative method of application, hydromulching using a seed/fertiliser mix similar to that<br />

specified above may be used.<br />

9.4 Quality Requirements – Verges, Footpaths and Verges<br />

9.4.1 Tolerances<br />

The following tolerances shall apply to finished kerbing and footpaths:<br />

Table 9.1<br />

Item<br />

Tolerances on Verges, Footpaths and Driveways<br />

Tolerance<br />

Ref No. 20120236SA1 <strong>Kingscote</strong> <strong>Streets</strong> <strong>Upgrades</strong> Technical Specification 43