On completion of construction of the scour protection apron the surrounding ground disturbed during<br />

the works shall be reinstated by filling as necessary and grading to conform to adjacent ground<br />

conditions.<br />

4.3.21 Connection to Existing Drain<br />

Construction of the design drains includes connecting to the existing drain or drains in the locations<br />

shown on the drawings.<br />

Design information provided on the location of existing drainage lines and structures may not be<br />

sufficiently accurate and is based in situ construction. The use of precast drainage structures shall<br />

be at the Contractor's risk.<br />

The Contractor shall ensure that interference with an existing drain does not impede the functioning<br />

of that drain, and the Contractor shall program the work to take account of likely flows and shall take<br />

all necessary measures to handle the existing flows and any consequences arising from the<br />

temporary interference shall be the responsibility of the Contractor.<br />

The connection of the design drain to the existing drain shall be constructed to the details shown on<br />

the drawings.<br />

4.3.21.1 Connection to Existing Concrete Channel, Pipe, Box Culvert or Junction Box<br />

The connection of the design drain to the existing concrete structure shall be a direct connection<br />

through the wall of the existing structure. The hole to accommodate the design drain shall be made<br />

in the wall of the structure using cutting or drilling tools as approved by the Superintendent to give a<br />

neat opening.<br />

The design drain shall be let into the hole so made and the joint shall be grouted in using a 1:3<br />

cement and sand mortar trowelled to a smooth surface. The end of the design drain shall be cut and<br />

trimmed so that the joint is finished flush with the internal wall of the existing structure.<br />

To ensure adhesion of the jointing materials, the end of the drain and the surface of the wall of the<br />

existing structure shall be thoroughly cleaned off and saturated with water before the joint is made.<br />

A concrete bandage shall be placed around the joint on the external surfaces.<br />

All concrete work shall be in accordance with the requirements of the Concrete and Concrete Work<br />

section of this specification.<br />

4.3.21.2 Connection by New Junction Box<br />

The connection of the design drain to the existing drain shall be at a new junction box to be<br />

constructed on the existing drain.<br />

The existing drain shall be exposed by excavation at the required location, and a junction box<br />

constructed to the details shown on the drawings. The portion of the existing drain within the<br />

junction box shall be broken out and removed. The ends of the existing drain shall be cut and<br />

trimmed such that the joints are finished flush with the internal walls of the new junction box.<br />

Alternatively, and subject to the prior approval of the Superintendent, the Contractor may elect to<br />

remove the portion of the existing drain no longer required by the design conditions prior to the<br />

junction box construction.<br />

The joints between the ends of the existing drain and the walls of the junction box shall be grouted in<br />

using a 1:3 cement and sand mortar trowelled to a smooth surface.<br />

The construction of the junction box shall comply with the requirements of the Drainage Structures<br />

clause in this section of the specification.<br />

4.3.21.3 Connection to Existing Open Earth Channel<br />

The connection of the design drain to the existing open earth channel shall be made by the<br />

construction of a reinforced concrete headwall at the end of the design drain.<br />