YOUR WISHES ARE OUR BENCHMARK<br />

Underfloor distributors<br />

Catalogue<br />

02


Table of Contents<br />

PIAZZA<br />

Introduction<br />

Overview<br />

PIAZZA<br />

PIAZZA 540<br />

PIAZZA 700<br />

PIAZZA 1000<br />

Pages 4 - 7<br />

Page 3<br />

Page 4<br />

Page 5<br />

Page 6<br />

Page 7<br />

PIAZZA<br />

Practical<br />

examples<br />

Installation<br />

instructions<br />

Pages 8 - 11<br />

Pages 8 - 10<br />

Page 11<br />

CAMPETTO<br />

Overview<br />

CAMPETTO<br />

CAMPETTO V<br />

CAMPETTO VI<br />

CAMPETTO VII<br />

CAMPETTO VIII<br />

Pages 12 - 16<br />

Page 12<br />

Page 13<br />

Page 14<br />

Page 15<br />

Page 16<br />

CAMPETTO<br />

Practical<br />

examples<br />

Installation<br />

instructions<br />

Pages 17 - 20<br />

Pages 17 - 19<br />

Page 20<br />

PICCOLINO /<br />

RETRANT<br />

PICCOLINO<br />

RETRANT<br />

Practical<br />

examples<br />

Pages 21 - 23<br />

Page 21 Page 22<br />

Page 23<br />

2 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Introduction<br />

Underfloor distributors<br />

virtually invisible - always within reach<br />

The structure of an underfloor distributor<br />

Thanks to our underfloor distributors, electrical power is quickly available<br />

anywhere and without time-consuming installation work! As with all of our<br />

products, we attach great importance to high-quality components<br />

and manufacturing. Only solid rubber distributors made in-house, with<br />

their outstanding material properties, are used.<br />

The benefits for you<br />

--<br />

Power available at any time and quickly<br />

--<br />

Ready for use immediately<br />

--<br />

Can be walked or driven over during operation<br />

--<br />

No power cables lying around, no danger of tripping<br />

--<br />

Covers can be individually filled / paved<br />

--<br />

Lockable in the contacted area<br />

--<br />

Gas springs for force-free, automatic opening<br />

--<br />

Frost-proof operation thanks to cover heating<br />

--<br />

Flooding-resistant on request<br />

--<br />

Maintenance-free solid rubber distributor system for electricity, water,<br />

compressed air and data connections, fittings as per the client's<br />

wishes<br />

Our services<br />

--<br />

Personalised, professional advice, including on site<br />

--<br />

Tried-and-tested product range<br />

--<br />

Tailored, customised solutions<br />

--<br />

Production of single and large series<br />

--<br />

Long spare parts availability<br />

Cable opening<br />

(for closed operation)<br />

Flexible connecting cable<br />

Electric supply line<br />

Outlet for drainage<br />

Built in accordance with:<br />

--<br />

BGA V1 and BGA V3<br />

--<br />

VDE 0100 Part 410 and 540<br />

--<br />

VDE 0660 Part 500<br />

--<br />

VDE 0660 Part 501 - depending on design<br />

--<br />

VDE 0471<br />

Power distributor<br />

Gas<br />

spring<br />

Connecting set<br />

Example view of an<br />

underfloor distributor<br />

Earthing plugs<br />

The right choice<br />

The following questions need to be answered in order to choose the right<br />

underfloor distributor:<br />

1. What power connections are wanted<br />

The size of the solid rubber distributor is defined by the socket occupancy<br />

and type of fuses used. The distributor is mounted on the cover of the<br />

underfloor distributor. The size of the power distribution also defines the<br />

junction box. We will be happy to provide more detailed information and<br />

explanations.<br />

2. Where will the underfloor distributor be installed<br />

Information regarding internal or external installation, along with how it<br />

will be used, is useful for ensuring the best possible design.<br />

3. Does the underfloor distributor need to be able to withstand traffic<br />

Your underfloor distributor is designed specifically for your needs.<br />

The higher the weight, the stronger the underfloor distributor and the<br />

foundations need to be.<br />

4. Do you want the cover to be filled<br />

If your underfloor distributor is to blend in perfectly with its surroundings,<br />

filling of the cover is required. There are no restrictions on the type of<br />

filling that can be used (cobbles, wood, tar, etc.).<br />

5. Is drainage guaranteed<br />

In order to protect the underfloor distributor from water damage, drainage<br />

must be guaranteed through the preparation of appropriate drainage<br />

(this is always the client's responsibility).<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

3


PIAZZA<br />

Overview of PIAZZA 540 / 700 / 1000<br />

PIAZZA 540 PIAZZA 700 PIAZZA 1000<br />

Product features<br />

--<br />

Sturdy, easy to use and safe in operation<br />

--<br />

Can be walked or driven over even during operation<br />

--<br />

Integrates perfectly into its surroundings thanks to customisable<br />

filling options<br />

--<br />

Secured against unauthorised opening (vandal-proof) and lockable<br />

in the contacted area<br />

--<br />

Easy and quick opening and closing, supported by gas springs<br />

--<br />

Frost-proof operation thanks to cover heating<br />

--<br />

The <strong>GIFAS</strong> solid rubber distributor guarantees optimum operating<br />

safety down to -40°C.<br />

--<br />

No formation of condensation thanks to the <strong>GIFAS</strong> solid rubber<br />

distributor<br />

--<br />

Resistant to environmental influences<br />

--<br />

Stainless steel construction, all metal parts made from V2A<br />

--<br />

Visible reflectors on the opened cover system<br />

--<br />

Distributor fastening on the underside of the cover<br />

--<br />

The connector distributor can be accessed when installed (E-check)<br />

--<br />

<strong>Pit</strong> cover, lock and distributor can be replaced<br />

Technical data PIAZZA 540 PIAZZA 700 PIAZZA 1000<br />

Area of use Internal / external area Internal / external area Internal / external area<br />

Classification as per EN 124 400kN (40t) / D400 400kN (40t) / D400 400kN (40t) / D400<br />

Cover Covers can be individually filled /<br />

paved<br />

580x580x70mm<br />

Covers can be individually filled /<br />

paved<br />

700x700x70mm<br />

Covers can be individually filled /<br />

paved<br />

1000x1000x70mm<br />

Weight Approx. 350kg Approx. 450kg Approx. 780kg<br />

Installation depth Approx. 1200mm Approx. 1300mm Approx. 1300mm<br />

<strong>GIFAS</strong> solid rubber distributors 3800 series 7800 series 7800/7900 series<br />

Can be equipped in accordance<br />

with the client's wishes (power,<br />

water, waste water, compressed<br />

air and EDP connections)<br />

Fuses<br />

1 CEE built-in socket<br />

5x16A/400V<br />

2 protective contact sockets<br />

1 RCCB 40/0.03A<br />

1 LP 16A / 3-pin<br />

2 LP 16A / 1-pin<br />

1 CEE built-in socket<br />

5x63A /400V<br />

1 CEE built-in socket 5x32A/400V<br />

1 CEE built-in socket 5x16A/400V<br />

3 protective contact sockets<br />

1 LP 63A / 3-pin<br />

1 LP 32A / 3-pin<br />

1 LP 16A / 3-pin<br />

3 LP 16A / 1-pin<br />

1 LP 63A / 3-pin pre-fusing<br />

1 RCCB 63/0.03A / 4-pin for 63A<br />

socket<br />

1 RCCB 63/0.03A/ 4-pin for the<br />

remaining sockets<br />

1 CEE built-in socket 5x63A/400V<br />

1 CEE built-in socket 5x32A/400V<br />

3 CEE built-in socket 5x16A/400V<br />

6 protective contact sockets<br />

1 LP 63A / 3-pin<br />

1 LP 32A / 3-pin<br />

3 LP 16A / 3-pin<br />

6 LP 16A / 1-pin<br />

1RCCB 63/0.03A for<br />

63A built-in socket<br />

1RCCB 63/0.03A for 16A built-in<br />

sockets<br />

1 RCCB 63/0.03A for 32A builtin<br />

socket and protective contact<br />

sockets<br />

4 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


PIAZZA<br />

PIAZZA 540<br />

Solid stainless steel construction (V2A) 540 x 540 mm, load capacity up<br />

to 400 kN, gas springs for fully automatic opening, shaft cover can be<br />

custom-filled, distributor as per the client's request.<br />

Technical additions<br />

Cover filling:<br />

Cable exit flap:<br />

Locking:<br />

Heating:<br />

The pit with a depth of 70 mm<br />

can be custom-filled to blend in with its<br />

surroundings.<br />

(180x130 mm) integrated into the shaft<br />

cover frame.<br />

A self-cleaning lock with snap fastener<br />

closes the shaft cover.<br />

Cable exit flap secured with a double bit<br />

lock (locking tool included in scope of<br />

delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

fillable shaft cover<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Mounted on concrete ring (H = 470 mm, NW = 600 mm).<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

5


PIAZZA<br />

PIAZZA 700<br />

Solid stainless steel construction (V2A) 700 x 700 mm, load capacity up<br />

to 400 kN, gas springs for fully automatic opening, shaft cover can be<br />

custom-filled, distributor as per the client's request.<br />

Technical additions<br />

Cover filling:<br />

Cable exit flap:<br />

Locking:<br />

Heating:<br />

The pit with a depth of 70 mm can be<br />

custom-filled to blend in with its surround<br />

ings.<br />

(180x130 mm) integrated into the shaft<br />

cover frame.<br />

A sturdy closing mechanism<br />

(with snap lock) closes the shaft cover<br />

and it can also be secured with a<br />

shackle lock.<br />

Cable exit flap secured with a double bit<br />

lock (locking tool included in scope of<br />

delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

fillable shaft cover<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Mounted on concrete ring (H = 470 mm, NW = 800 mm).<br />

6 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


PIAZZA<br />

PIAZZA 1000<br />

Solid stainless steel construction (V2A) 1000 x 1000 mm, load capacity<br />

up to 400 kN, gas springs for fully automatic opening, shaft cover can be<br />

custom-filled, distributor as per the client's request.<br />

Technical additions<br />

Cover filling:<br />

Cable exit flap:<br />

Locking:<br />

Heating:<br />

The pit with a depth of 70 mm can be<br />

custom-filled to blend in with its surround<br />

ings.<br />

(180x130 mm) integrated into the shaft<br />

cover frame.<br />

A sturdy closing mechanism<br />

(with snap lock) closes the shaft cover<br />

and it can also be secured with a<br />

shackle lock.<br />

Cable exit flap secured with a double bit<br />

lock (locking tool included in scope of<br />

delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

fillable shaft cover<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Mounted on concrete ring (H = 470 mm, NW = 1000 mm).<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

7


Practical examples<br />

PIAZZA<br />

Lübeck town hall market, PIAZZA with payment system<br />

Lübeck town hall market, PIAZZA with payment system<br />

Lübeck town hall market, PIAZZA with payment system<br />

Dresden “Altmarkt”, PIAZZA 700<br />

Munich Residence, PIAZZA 700<br />

Munich Residence, PIAZZA 700<br />

8 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Practical examples<br />

PIAZZA<br />

Thyssen, PIAZZA 700 Thyssen, PIAZZA 700<br />

Wiesbaden Assembly Rooms, PIAZZA 700 Wiesbaden Assembly Rooms, PIAZZA 700<br />

Dresden "Zwinger", PIAZZA 700 Dresden "Zwinger", PIAZZA 700<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

9


Practical examples<br />

PIAZZA<br />

Detmold marketplace, PIAZZA 1000 Detmold marketplace, PIAZZA 1000<br />

Hangar, PIAZZA 2000 Hangar, PIAZZA 2000<br />

Färöer-Islands Airport, PIAZZA 2000 Air base, PIAZZA 2000<br />

10 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Installation instructions<br />

PIAZZA installation and assembly procedure<br />

Excavating the installation pit Customer-side concrete ring Insertion of the unit<br />

Insertion of the entire unit into the<br />

prepared installation pit<br />

Levelling<br />

Decanting and concreting-in<br />

Adaptation to the<br />

surroundings<br />

with filler material<br />

Fully installed PIAZZA<br />

With underfloor systems involving fresh water, the terminal<br />

distributor must be hung on the side opposite the water tap!<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

11


CAMPETTO<br />

Overview of CAMPETTO V / VI / VII / VIII<br />

CAMPETTO V CAMPETTO VI CAMPETTO VII CAMPETTO VIII<br />

Product features<br />

--<br />

Sturdy, easy to use and safe in operation<br />

--<br />

Can be walked or driven over even during operation<br />

--<br />

Integrates perfectly into its surroundings thanks to customisable<br />

filling options<br />

--<br />

Secured against unauthorised opening (vandal-proof) and lockable<br />

in the contacted area<br />

--<br />

Easy and quick opening and closing, supported by gas springs<br />

--<br />

Frost-proof operation thanks to cover heating option<br />

--<br />

The <strong>GIFAS</strong> solid rubber distributor guarantees optimum operating<br />

Safety down to -40°C.<br />

--<br />

No formation of condensation thanks to the <strong>GIFAS</strong> solid rubber<br />

distributor<br />

--<br />

Resistant to environmental influences<br />

--<br />

Stainless steel construction, all metal parts made from V2A<br />

--<br />

Visible reflectors on the opened cover system<br />

--<br />

Cover pit can be removed by loosening the screws for maintenance<br />

purposes<br />

--<br />

Distributor fastening on the underside of the cover<br />

--<br />

The connector distributor can be accessed when installed (E-check)<br />

--<br />

<strong>Pit</strong> cover, lock and distributor can be replaced<br />

Technical data CAMPETTO V CAMPETTO VI CAMPETTO VII CAMPETTO VIII<br />

Area of use Internal / external area Internal / external area Internal / external area Internal / external area<br />

Maximum load<br />

Classification<br />

as per EN 124<br />

Cover<br />

Up to 30kN (3t), special<br />

designs 50kN<br />

125kN (12.5t)<br />

Up to 30kN (3t)<br />

Special designs 50kN<br />

125kN (12.5t)<br />

15kN (1.5t) / A15 125kN (12.5t) / B125 15kN (1.5t) / A15 125kN (12.5t) / B125<br />

Stainless steel non-slip<br />

steel floor plate,<br />

can be supplied in two<br />

sizes<br />

628x435mm / 778x535mm<br />

Covers can be individually<br />

filled / paved<br />

can be supplied in two<br />

sizes<br />

628x435mm / 778x535mm<br />

Stainless steel non-slip<br />

steel floor plate<br />

880x992mm<br />

Covers can be individually<br />

filled / paved<br />

880x992mm<br />

Weight Approx. 60kg Approx. 70kg Approx. 250kg Approx. 250kg<br />

Installation depth<br />

Dependent on design Dependent on design 1000mm<br />

1000mm<br />

500 or 670mm<br />

500 or 670mm<br />

<strong>GIFAS</strong> solid rubber<br />

distributors<br />

Can be equipped in<br />

accordance with the client's<br />

wishes (power, water, waste<br />

water, compressed air and<br />

EDP connections)<br />

Fuses<br />

Individual series 7200 to<br />

7900<br />

1 CEE built-in socket<br />

5x32A/400V<br />

1 CEE built-in socket<br />

5x16A/400V<br />

3 protective contact<br />

sockets<br />

1 LP 32A / 3-pin<br />

1 LP 16A / 3-pin<br />

3 LP 16A / 1-pin<br />

1 LP 63A / 3-pin for prefusing<br />

1 RCCB 63/0.03 A / 4-pin<br />

for all sockets<br />

Individual series 7200 to<br />

7900<br />

1 CEE built-in socket<br />

5x32A/400V<br />

1 CEE built-in socket<br />

5x16A/400V<br />

3 protective contact<br />

sockets<br />

1 LP 32A / 3-pin<br />

1 LP 16A / 3-pin<br />

3 LP 16A / 1-pin<br />

1 LP 63A / 3-pin for prefusing<br />

1 RCCB 63/0.03A / 4-pin for<br />

all sockets<br />

Individual series 7200 to<br />

7900<br />

1 CEE built-in socket<br />

5x63A/400V<br />

1 CEE built-in socket<br />

5x32A/400V<br />

3 CEE built-in socket<br />

5x16A/400V<br />

6 protective contact<br />

sockets<br />

1 LP 63A / 3-pin<br />

1 LP 32A / 3-pin<br />

3 LP 16A / 3-pin<br />

6 LP 16A / 1-pin<br />

1 RCCB 63/0.03A for 63A<br />

built-in socket<br />

1 RCCB 63/0.03A for 16A<br />

built-in socket<br />

1 RCCB 63/0.03A for 32A<br />

built-in socket protective<br />

contact sockets<br />

Individual series 7200 to<br />

7900<br />

1 CEE built-in socket<br />

5x63A/400V<br />

1 CEE built-in socket<br />

5x32A/400V<br />

3 CEE built-in socket<br />

5x16A/400V<br />

6 protective contact<br />

sockets<br />

1 LP 63A / 3-pin<br />

1 LP 32A / 3-pin<br />

3 LP 16A / 3-pin<br />

6 LP 16A / 1-pin<br />

1 RCCB 63/0.03A for 63A<br />

built-in socket<br />

1 RCCB 63/0.03A for 16A<br />

built-in socket<br />

1 RCCB 63/0.03A for 32A<br />

built-in socket protective<br />

contact sockets<br />

12 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


CAMPETTO<br />

CAMPETTO V<br />

Solid stainless steel construction (V2A) in two sizes, load capacity up<br />

to 30 kN (special design up to 50 kN), gas springs for fully automatic<br />

opening, shaft cover made from non-slip steel floor plate, distributor as<br />

per the client's request.<br />

Technical additions<br />

Cover:<br />

Cable exit flap:<br />

Locking:<br />

Heating (optional):<br />

V2A non-slip steel floor plate.<br />

(135x90 mm) in the centre on the head<br />

side of the cover.<br />

A self-cleaning lock with snap fastener<br />

closes the shaft cover (locking tool includ<br />

ed in the scope of delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

Sand<br />

Gravel<br />

Pavement<br />

Concrete<br />

collar<br />

for distributors<br />

7200 – 7400<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

cover made from V2A non-slip steel floor plate<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Sand<br />

Gravel<br />

Pavement<br />

Concrete<br />

collar<br />

for distributors<br />

7700 – 7900<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

13


CAMPETTO<br />

CAMPETTO VI<br />

Solid stainless steel construction (V2A) in two sizes, load capacity up<br />

to 125 kN, gas springs for fully automatic opening, shaft cover can be<br />

custom-filled, distributor as per the client's request.<br />

Pavement<br />

Technical additions<br />

Sand<br />

Cover filling:<br />

Cable exit flap:<br />

Locking:<br />

Heating (optional):<br />

The pit with a depth of 70 mm can be<br />

custom-filled to blend in with its surround<br />

ings.<br />

(135x90 mm) in the centre on the head<br />

side of the cover.<br />

A self-cleaning lock with snap fastener<br />

closes the shaft cover (locking tool includ<br />

ed in the scope of delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

Gravel<br />

Concrete<br />

collar<br />

for distributors<br />

7200 – 7400<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

fillable shaft cover<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Sand<br />

Gravel<br />

Pavement<br />

Concrete<br />

collar<br />

for distributors<br />

7700 – 7900<br />

14 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


CAMPETTO<br />

CAMPETTO VII<br />

992<br />

Solid stainless steel construction (V2A), load capacity up to 15 kN<br />

(special design up to 50 kN), gas springs for fully automatic opening,<br />

shaft cover made from non-slip steel floor plate, distributor as per the<br />

client's request.<br />

Technical additions<br />

Cover:<br />

Cable exit flap:<br />

Locking:<br />

Heating (optional):<br />

V2A non-slip steel floor plate.<br />

(135x90 mm) in the centre on the head<br />

side of the cover.<br />

A self-cleaning lock with snap fastener<br />

closes the shaft cover (locking tool includ<br />

ed in the scope of delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

Sand<br />

Sand<br />

Gravel Kies<br />

Pavement<br />

Bepflasterung<br />

Concrete collar<br />

Betonmanschette<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

940<br />

for distributors<br />

7200 – 7900<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

cover made from V2A non-slip steel floor plate<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

15


CAMPETTO<br />

CAMPETTO VIII<br />

992<br />

Solid stainless steel construction (V2A), load capacity up to 125 kN, gas<br />

springs for fully automatic opening, shaft cover can be custom-filled,<br />

distributor as per the client's request.<br />

Technical additions<br />

Cover filling:<br />

Cable exit flap:<br />

Locking:<br />

Heating (optional):<br />

The pit with a depth of 70 mm can be<br />

custom-filled to blend in with its surround<br />

ings.<br />

(280x90 mm) in the centre on the head<br />

side of the cover.<br />

A self-cleaning lock with snap fastener<br />

closes the shaft cover (locking tool includ<br />

ed in the scope of delivery).<br />

The manhole cover is a thermostatic<br />

controlled heating band relocated to<br />

Frost at an easy opening to<br />

guarantee.<br />

Sand<br />

Gravel Kies<br />

Pavement Bepflasterung<br />

Concrete Betonmanschette collar<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

940<br />

for distributors 7200 – 7900<br />

Supplied package<br />

Stainless steel construction with<br />

--<br />

fillable shaft cover<br />

--<br />

solid rubber electrical distributor<br />

--<br />

junction box<br />

Fully assembled and wired.<br />

16 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Practical examples<br />

CAMPETTO<br />

BUGA Koblenz, CAMPETTO with diving bell<br />

BUGA Koblenz, CAMPETTO with diving bell<br />

BUGA Schwerin, CAMPETTO V<br />

London Olympic Games, CAMPETTO VI<br />

Bad Saarow station, CAMPETTO VI<br />

Bad Saarow station, CAMPETTO VI<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

17


Practical examples<br />

CAMPETTO<br />

Meckenbeuren church square, CAMPETTO VI<br />

Meckenbeuren church square, CAMPETTO VI<br />

Daimler presentation hall, CAMPETTO VI<br />

Daimler presentation hall, CAMPETTO VI<br />

Hotel Grand Spa Resort Sylt, CAMPETTO VI<br />

Melitta Minden, CAMPETTO VI<br />

18 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Practical examples<br />

CAMPETTO<br />

Town of Illertissen, CAMPETTO VI<br />

Pforzheim marketplace, CAMPETTO VI<br />

Hampton Court Palace, CAMPETTO VI<br />

Sea King Militär Hangar, CAMPETTO VIII<br />

Max Planck Institute, CAMPETTO VIII<br />

Hamburg CruiseCenter, CAMPETTO VIII<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

19


Installation instructions<br />

CAMPETTO installation and assembly procedure<br />

Excavating the installation pit Topping up the installation pit Insertion of the unit<br />

Filling Decanting and concreting-in Adaptation to the surroundings<br />

with filler material<br />

Fully installed CAMPETTO<br />

20 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


PICCOLINO<br />

PICCOLINO 120 / 200<br />

PICCOLINO 120 PICCOLINO 200<br />

Product features<br />

--<br />

Solid stainless steel construction, rust-free<br />

--<br />

Completely maintenance-free (E-check)<br />

--<br />

Cover made from non-slip steel floor plate<br />

--<br />

Easy operation<br />

--<br />

Can be walked or driven over during operation<br />

--<br />

Ground-flush installation<br />

--<br />

Excellent operating safety thanks to reclosing after commissioning<br />

--<br />

Locking is performed using a countersunk, cover-flush dual bit lock (1<br />

key included in the scope of delivery)<br />

--<br />

Cable exit opening in the cover lid for cables up to d = 15 mm<br />

(PICCOLINO 120), d = 25 mm (PICCOLINO 200)<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Technical data PICCOLINO 120 PICCOLINO 200<br />

Area of use Underfloor distributors for restricted spaces Underfloor distributors for restricted spaces<br />

Classification as per EN 124 2kN (200kg) 250kN (25 t) / C250<br />

Cover<br />

Stainless steel non-slip steel floor plate<br />

120x120mm<br />

Weight Approx. 4.2kg Approx. 7.5kg<br />

Installation depth Approx. 400mm Approx. 400mm<br />

Equipment options 2m <strong>GIFAS</strong>-PROFLEXX-07 cable 3x2.5 m 2<br />

1 protective contact coupling 16A/230V (IP 68)<br />

or<br />

1 CEE coupling 16A/400V (IP67)<br />

Stainless steel non-slip steel floor plate<br />

200x200mm<br />

2m <strong>GIFAS</strong>-PROFLEXX-07 cable 3x2.5 m 2<br />

1 protective contact coupling 16A/230V (IP 68)<br />

or<br />

1 CEE coupling 5x16A/400V (IP 67) or<br />

1 CEE coupling 5x32A/400V (IP 67)<br />

Twist protection<br />

Twist protection<br />

Potential Earth<br />

cross slot screw<br />

Potential Earth<br />

cross slot screw<br />

Schuko-socket<br />

WD 230V 16A<br />

holder<br />

socket<br />

2m <strong>GIFAS</strong><br />

PROFLEXX 3x2,5<br />

(connection and<br />

shrinking need to<br />

be executed at<br />

contruction side)<br />

Potential Earth<br />

M8 bolt<br />

2m <strong>GIFAS</strong><br />

PROFLEXX 3x2,5<br />

(connection and<br />

shrinking need to<br />

be executed at<br />

contruction side)<br />

cable exit<br />

square<br />

sash<br />

fastener<br />

cable exit<br />

square sash<br />

fastener<br />

PICCOLINO 120 PICCOLINO 200<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

21


RETRANT<br />

RETRANT<br />

Product features<br />

--<br />

Solid stainless steel construction, rust-free<br />

--<br />

Completely maintenance-free (E-check)<br />

--<br />

Cover made from non-slip steel floor plate<br />

--<br />

Easy operation<br />

--<br />

Can be walked or driven over during operation<br />

--<br />

Ground-flush installation<br />

--<br />

Excellent safety thanks to the <strong>GIFAS</strong> double pressure method; the<br />

cover is held securely closed even without a lock<br />

--<br />

Locking is performed using a countersunk, cover-flush dual bit lock (1<br />

key included in the scope of delivery)<br />

--<br />

Cable exit for cables is located in the shaft cover<br />

It is the client's responsibility to ensure the standards-appropriate<br />

substructure, correct installation of the shaft and corresponding<br />

drainage. The shaft cover is not sealed against surface water.<br />

Technical data<br />

RETRANT<br />

Area of use<br />

Classification as per EN 124<br />

Underfloor distributors for restricted spaces<br />

15kN (1.5t) / A15<br />

Cover<br />

Stainless steel non-slip steel floor plate<br />

340x240mm<br />

Weight<br />

Approx. 25kg<br />

Installation depth<br />

Approx. 420mm<br />

<strong>GIFAS</strong> solid rubber distributors Series 2516, protection category IP 65<br />

Equipment options<br />

Individual as per the client's wishes<br />

1 CEE built-in socket 5x32A/400V in straight design<br />

1 protective contact socket 230V (IP 68)<br />

Cable input<br />

Stainless steel cover<br />

Cable outlet 50 x 50 mm<br />

Solid rubber casing type 2516<br />

Lower part steel casing<br />

22 <strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong> · Borsigstrasse 9 · 41469 Neuss · GERMANY


Practical examples<br />

PICCOLINO / RETRANT<br />

Apartment house, PICCOLINO 200<br />

Town of Lingen, RETRANT<br />

Wiesbaden Assembly Rooms, RETRANT<br />

Wiesbaden Assembly Rooms, RETRANT<br />

Lübeck town hall market, RETRANT<br />

Bremen “Wesercafé”, RETRANT<br />

Telephone +49 2137 105-0 · Fax +49 2137 105-230 · verkauf@gifas.de · www.gifas.de<br />

23


CONTACT US TODAY<br />

Technical modifications reserved 11/2013<br />

New products and specialist solutions, along with the latest product catalogue,<br />

can be found on our website.<br />

www.gifas.de<br />

<strong>GIFAS</strong> <strong>ELECTRIC</strong> <strong>GmbH</strong><br />

Borsigstrasse 9<br />

41469 Neuss<br />

GERMANY<br />

Phone +49 2137 105-0<br />

Fax: +49 2137 105-230<br />

verkauf@gifas.de<br />

www.gifas.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!