MATERIAL DATA SHEET<br />
(TDI) TERMINATED POLYETHER (PTMEG) POLYMER<br />
PRE-POL® T-444<br />
<strong>Typical</strong> <strong>Properties</strong><br />
NCO%, 4.10-4.50<br />
Viscosity, poise @ 212°F (100°C) 3.00-6.00<br />
Specific Gravity @ 158°F (70°C) : 1.06<br />
Appearance @ 77°F (25°C): Viscous liquid<br />
Flash Point, Cleveland Open Cup 400F (204C)<br />
<strong>Typical</strong> <strong>Physical</strong> <strong>Properties</strong> <strong>using</strong> MOCA E-300<br />
Hardness Shore A 90 88<br />
Resilience % Rebound 48 45<br />
Split Tear Strength<br />
ASTM T-624 PLI(kN/m) 87 (15.3) 81 (14.2)<br />
Die C Tear Strength<br />
ASTM D-624 PLI(kN/m) 510 (89.4) 548 (96.1)<br />
Tensile Strength<br />
ASTM D-470 PSI(MPa) 5558 (38.3) 5732 (39.5)<br />
Product Description:<br />
PRE-POL® T-444 is a TDI terminated polyether (PTMEG)<br />
prepolymer for use in high property elastomers,<br />
elastomeric coatings and adhesives. As with all<br />
Ultimate Elongation % 633 847<br />
100% Modulus PSI(MPa) 1095 (7.55) 963 (6.64)<br />
300% Modulus PSI(MPa) 2042 (14.1) 1601 (11.0)<br />
Compression<br />
Set(method B)<br />
22 Hr @158°F(70°C) % 31 32<br />
polyurethane products, application and field testing are<br />
necessary to determine suitability of the product<br />
combination for specific application.<br />
Storage and Handling:<br />
Containers should be kept tightly closed to prevent<br />
moisture contamination. TDI will react with water to liberate<br />
CO₂ gas potentially ca<strong>using</strong> containers to expand and<br />
rupture. Do not reseal if contamination is suspected.<br />
Use of a dry nitrogen blanket for partial drums is<br />
recommended. Storage for PRE-POL® T-444 should be<br />
maintained in a cool, dry place at ambient temperatures.<br />
Processing Characteristics <strong>using</strong> MOCA E-300<br />
NCO Range % 4.3 4.3<br />
Curative PPH 13.2 15.2<br />
Stoichiometry % 95 95<br />
Prepolymer temperature °F(C°) 176ºF (80°C) 160ºF 71.1°C()<br />
Curative temperature °F(C°) 240ºF (115°C) 80ºF (26.7°c)<br />
Pot Life minutes 8-10 8-10<br />
Demold Time minutes 45 45<br />
Postcure Cycle 212°F<br />
(100°C)<br />
hours 16 16<br />
Exposure to temperatures over 350°F (177°C) can create excessive pressure potentially ca<strong>using</strong> containers to rupture. Do not breathe aerosol<br />
or vapors and avoid contact with skin and eyes. Use protective equipment including respirator when handling heated TDI a handling as<br />
exposure to vapors of heated TDI can be dangerous. To heat product properly, use well ventilated convection ovens. Avoid <strong>using</strong> drum heaters.<br />
Health and Safety Information:<br />
Appropriate literature has been assembled which provides information concerning the health and safety precautions that must be observed<br />
when<br />
handling any of the products listed above. Before working with these products, it is your responsibility to read and become familiar with<br />
the available information on its hazards, proper use and handling. This is extremely important and cannot be overemphasized. Information is<br />
<strong>Polycoat</strong> <strong>Products</strong><br />
A Division of American Polymers Corp.<br />
14722 Spring Street, Santa Fe Springs, CA 90670-5108 USA<br />
TEL 562-802-8834 FAX 562-921-7363<br />
Copyright© Sept 2011 <strong>Polycoat</strong> <strong>Products</strong>
available in several forms, e.g. material safety data sheets and product labels. To obtain this information, contact your <strong>Polycoat</strong> <strong>Products</strong><br />
representative.<br />
Please read all information in the general guidelines, product data sheets, guide specifications and material safety data sheets (MSDS) before applying<br />
material. Published technical data and instructions are subject to change without notice. Contact your local <strong>Polycoat</strong> <strong>Products</strong> representative or visit our<br />
website for current technical data and instructions.<br />
DISCLAIMER<br />
All guidelines, recommendations, statements, and technical data contained herein are based on information and tests we believe to be reliable and correct,<br />
but accuracy and completeness of said tests are not guaranteed and are not to be construed as a warranty, either expressed or implied. It is the user's<br />
responsibility to satisfy himself, by his own information and test, to determine suitability of the product for his own intended use, application and job<br />
situation and user assumes all risk and liability resulting from his use of the product. We do not suggest or guarantee that any hazards listed herein are the<br />
only ones which may exist. Neither seller nor manufacturer shall be liable to the buyer or any third person for any injury, loss or damage directly or indirectly<br />
resulting from use of, or inability to use, the product. Recommendations or statements, whether in writing or oral, other than those contained herein shall<br />
not be binding upon the manufacturer, unless in writing and signed by a corporate officer of the manufacturer. Technical and application information is<br />
provided for the purpose of establishing a general profile of the material and proper application procedures. Test performance results were obtained in a<br />
controlled environment and <strong>Polycoat</strong> <strong>Products</strong> makes no claim that these tests or any other tests accurately represent all environments.<br />
14722 Spring Avenue, Santa Fe Springs, CA 90670-5108 USA ♦ Tel: 562/802-8834 ♦ Fax: 562/921-7363 ♦ www.polycoatusa.com ♦ Copyright© Sept 2011 <strong>Polycoat</strong> <strong>Products</strong>