• 50 % <strong>of</strong> normal speed if the occupant assists another, and 30 % faster than this adjusted value<br />

if the occupant considers the situation to be serious.<br />

• 60 % <strong>of</strong> normal speed <strong>of</strong> the smoke is bad (S>0.4) and the (H-D) (depth <strong>of</strong> lower layer) is<br />

less than 1.5 m<br />

Output: The output includes the number <strong>of</strong> occupants out <strong>of</strong> the building, those trapped, and the<br />

total evacuation time. The actions <strong>of</strong> individual occupants at all time periods throughout the<br />

simulation are also included in the output.<br />

Use <strong>of</strong> fire data: EXITT is designed to import output from FAST to simulate smoke throughout<br />

the building. This assumes a 2-layer smoke distribution. EXITT also accepts input <strong>of</strong> smoke<br />

density in the upper layer and the height <strong>of</strong> the two layers in each room at each time period.<br />

Import CAD drawings: No, CAD drawings <strong>of</strong> the building cannot be imported into EXITT.<br />

The building is described by providing the number <strong>of</strong> rooms, nodes, and exits, the height <strong>of</strong> each<br />

room, the room location <strong>of</strong> each node, whether the exit was a door, window, etc., and the<br />

distances between the nodes. If a window cannot be used for evacuation, it is not included into<br />

the model.<br />

Visualization capabilities: The movement <strong>of</strong> the occupants can be displayed graphically on the<br />

computer screen.<br />

Validation studies: None noted.<br />

Special features:<br />

Manual exit block/obstacles – Yes, if smoke is very heavy (which can be input by the user)<br />

Fire conditions affect behavior Yes, these can be imported from FAST or user-defined (OD<br />

and smoke layer heights) per time period.<br />

Defining groups – Yes, capable and needs assistance.<br />

Disabilities/slow occupant groups – Yes.<br />

Delays/pre-movement time – Delays are associated with the activities during a preparation and<br />

response time.<br />

Route choice <strong>of</strong> the occupants/occupant distribution – Route choice is dependent on a list <strong>of</strong><br />

information, many <strong>of</strong> it conditional to the environment, during the evacuation as well as the<br />

familiarity with the building.<br />

Limitations: This model is used only for residential buildings. Occupants respond to smoke<br />

conditions only, not toxicity or heat. Also, many <strong>of</strong> decision rules are based on author judgment.<br />