Table 3. Model Available on a Consultancy Basis<br />
Characteristics/Model PathFinder EESCAPE Myriad<br />
Avail to public N1 N1 N1<br />
Method Movement Movement Movement<br />
Structure Fine Coarse N/A<br />
Perspective <strong>of</strong> M/O I/G Global Individual<br />
People beh None None None<br />
Import CAD drawings Y N Y<br />
Visual simulation Y N Y<br />
Counterflow N N Y – congestion<br />
Manual exit block N N N<br />
Fire conditions N N N<br />
Defining groups N N N<br />
Disabl/Slow occ grps N N N<br />
Delays/Pre-movement N N Y – interaction<br />
related<br />
Rte. choice 2 Choices 1-route Available<br />
Elevator use N N N<br />
Toxicity to occ N N N<br />
Impatience/Drive N N N<br />
Occ. distribution UC – 2 choices 1 choice only Various<br />
Characteristics/Model ALLSAFE CRISP EGRESS<br />
Avail to public N1 N1 N1<br />
Method Partial Behavior B-RA Behavioral<br />
Structure Coarse Fine Fine<br />
Perspective <strong>of</strong> M/O Global Individual Individual<br />
People beh Implicit Conditional Conditional<br />
Import CAD drawings N Y N<br />
Visual simulation Y Y Y<br />
Counterflow N Y Y<br />
Manual exit block N Y Y<br />
Fire conditions Y Y – not in drill<br />
Y<br />
mode<br />
Defining groups Y Y Y<br />
Disabl/Slow occ grps N Y Y<br />
Delays/Pre-movement Y Y Y<br />
Rte. choice All to 1 exit Shortest, user Conditional<br />
defined door<br />
difficulty<br />
Elevator use N N N<br />
Toxicity to occ N Y – not in drill Y<br />
Impatience/Drive N N N<br />
Occ distribution 1 choice Conditional Various<br />
16