E.11.0 Mains systems<br />

E.11.2 Mains 24 V DC<br />

The aforementioned colour-coding rule does not apply to the<br />

low-voltage mains network.<br />

The low voltage mains network at VÖGELE operates at 24 V DC.<br />

However, the wires are coloured and a few „VÖGELE rules“ do apply.<br />

Abbreviations:<br />

wt – white / bk – black / rd – red / gr – grey / gn – green /<br />

yl – yellow / vio – violet / bn – brown / bl – blue<br />

Some wires also have two colours. Such combinations can be<br />

encountered with virtually all colours, such as wtyl = white/yellow;<br />

bkgn = black/green; brbl = brown/blue.<br />

However, black wires printed with a number are usually used<br />

nowadays.<br />

Example: Two-colour wire<br />

VÖGELE rules:<br />

The connecting wires on solenoids usually have even numbers<br />

(2,4,6,8, etc.) on the earth side (exception: Danfoss).<br />

Earth wires are usually brown or brown/white (8V earth).<br />

As of the -1 Series, all internal wiring is finished in terminal box<br />

blue.<br />

As of Ergo Plus, the connecting wires between the terminal box<br />

and control desk are white (0.5mm²).<br />

Internal wiring<br />

Earth<br />

Example: Terminal box