E.11.0 Mains systems<br />
E.11.2 Mains 24 V DC<br />
The aforementioned colour-coding rule does not apply to the<br />
low-voltage mains network.<br />
The low voltage mains network at VÖGELE operates at 24 V DC.<br />
However, the wires are coloured and a few „VÖGELE rules“ do apply.<br />
Abbreviations:<br />
wt – white / bk – black / rd – red / gr – grey / gn – green /<br />
yl – yellow / vio – violet / bn – brown / bl – blue<br />
Some wires also have two colours. Such combinations can be<br />
encountered with virtually all colours, such as wtyl = white/yellow;<br />
bkgn = black/green; brbl = brown/blue.<br />
However, black wires printed with a number are usually used<br />
nowadays.<br />
Example: Two-colour wire<br />
VÖGELE rules:<br />
The connecting wires on solenoids usually have even numbers<br />
(2,4,6,8, etc.) on the earth side (exception: Danfoss).<br />
Earth wires are usually brown or brown/white (8V earth).<br />
As of the -1 Series, all internal wiring is finished in terminal box<br />
blue.<br />
As of Ergo Plus, the connecting wires between the terminal box<br />
and control desk are white (0.5mm²).<br />
Internal wiring<br />
Earth<br />
Example: Terminal box