Features:<br />

• Electronically<br />

Commutated (<strong>EC</strong>)<br />

fan motor<br />

• Specific <strong>Fan</strong> Power<br />

of 0.16 to 0.34 at<br />

NR35<br />

• Insignificant<br />

fan heat gain<br />

• Designed to operate<br />

below NR35 at<br />

External Static<br />

Pressures of up to<br />

50Pa<br />

• Variable speed<br />

<strong>Fan</strong> adjustment<br />

• Ceiling and<br />

Underfloor<br />

installation<br />

• Low surface<br />

temperature on<br />

electric element<br />

• Low Maintenance<br />

<strong>Highline</strong> <strong>260i</strong> <strong>EC</strong> <strong>Waterside</strong> <strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong>


<strong>Highline</strong> <strong>260i</strong> <strong>EC</strong> <strong>Waterside</strong> <strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong><br />

<strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong><br />

The most popular waterside control fan<br />

coil unit in the UK for the past 15<br />

years, now available with <strong>EC</strong> fans<br />

having low Specific <strong>Fan</strong> Powers.<br />

Initially designed to be fitted into a<br />

ceiling void, the flexibility also allows<br />

the unit to be installed underfloor.<br />

Furthermore an alternative to the<br />

standard design is the <strong>Highline</strong> 260d,<br />

which incorporates a detachable<br />

discharge plenum and enables a more<br />

flexible discharge arrangement.<br />

Chassis<br />

<strong>Unit</strong>s are manufactured from 1.0 -<br />

1.6mm hot dipped galvanised steel and<br />

are constructed without the use of self<br />

tapping screws. All thermal and<br />

acoustic lining is CFC and HCFC free<br />

and class ‘O’ fire rated. All bearings<br />

and moving surfaces will operate<br />

without requiring further lubrication.<br />

All electrical components and electrical<br />

wiring comply with the current edition<br />

of the I.E.E. regulations. Each unit is<br />

factory tested to ensure that it will<br />

continue to meet its specified<br />

performance with the minimum of<br />

maintenance, throughout its life.<br />

<strong>Fan</strong>s<br />

The fans are of the double inlet, double<br />

width centrifugal type. The scrolls are<br />

manufactured from galvanised mild<br />

steel, complete with forward curved<br />

aluminium or galvanised steel bladed<br />

impellers. All fan and motor assemblies<br />

are statically and dynamically balanced<br />

to prevent the transmission of vibration<br />

to the fan coil unit casing. Each fan<br />

and motor assembly has thermal<br />

overload protection fitted, via<br />

imbedded thermistors or the<br />

commutation electronics. The motors<br />

comply to BS 5000-11 and BS EN<br />

60034. The motor frame is totally<br />

enclosed and fitted with maintenance<br />

free sealed for life ball bearings.<br />

Motors are insulated to BS 2757 class<br />

B (minimum) and tested to BS EN<br />

61000-3-2 for Harmonic Distortion<br />

and BS EN 61000-3-3 for Flicker.<br />

Heat Exchangers <strong>Coil</strong>s are<br />

manufactured from 0.35 mm thick<br />

solid drawn copper tubes, mechanically<br />

expanded into accurately pre-formed<br />

collars in rippled aluminium fins. The<br />

coils are arranged for single or multicircuit<br />

operation via headers. Each<br />

coil is fitted with a manual air vent and<br />

drain point. All coils are factory tested<br />

to a minimum of 35 bar and are<br />

suitable for operating pressures of up to<br />

12 bar static head. <strong>Coil</strong>s are fitted<br />

with 15 mm o/d plain copper tails.<br />

Condensate Drip Tray<br />

The condensate drip tray is manufactured<br />

from hot dipped galvanised steel, welded<br />

at each corner. The tray is then degreased<br />

before anti-condensation insulation is<br />

applied to all internal and external<br />

surfaces. The tray is fitted with 15 mm o/<br />

d plain brass connection (22 mm o/d<br />

optional). The tray has a built in gradient<br />

to ensure correct drainage of condensate.<br />

Temperature Controls<br />

(WATERSIDE)<br />

Temperature control shall be by<br />

modulation of the control valves<br />

allowing either chilled or heated water<br />

to flow through the appropriate coil.<br />

Air Filter Options<br />

• Mesh Filter - The filter is<br />

permanent and is manufactured<br />

from a fine woven mesh of<br />

galvanised steel wire, welded to a<br />

rigid galvanised steel frame. It can<br />

be vacuum cleaned in-situ, or<br />

periodically removed for washing<br />

when necessary<br />

• Media type filter - Filters are EU2<br />

to Eurovent 4/5 and manufactured<br />

from a synthetic media secured to a<br />

wire metal frame and fitted<br />

with<br />

handles for<br />

ease of cleaning and<br />

replacement.<br />

Discharge/ Inlet Plenum<br />

The discharge and inlet plenums are<br />

attenuated and thermally lined with a<br />

CFC and HCFC free class ‘O’ fire<br />

retardant non-migratory foam, which<br />

is both vermin and rot proof. The<br />

density of the foam is 11 kg/m³<br />

thereby helping to reduce the total<br />

weight of the fan coil unit.<br />

Electric Heat Element (if required)<br />

The element is manufactured from<br />

stainless steel sheath with spiral<br />

wound stainless steel fins to minimise<br />

surface temperature. It is located<br />

upstream of the fan(s) to evenly<br />

distribute the heat to the final<br />

discharge spigots. Each unit shall<br />

incorporate a manual reset high<br />

temperature cut-out and a Pressure<br />

Differential Switch or Current Switch,<br />

wired to prevent operation in the<br />

event of a fan failure.


THERMAL<br />

PERFORMANCE<br />

EL<strong>EC</strong>TRIC DATA/<br />

FAN PERFORMANCE<br />

Model & Size<br />

Air Vol. l/s<br />

Speed<br />

Sens. Duty<br />

Watts<br />

Total Duty<br />

Watts<br />

CHW Flow<br />

Rate l/s<br />

Hyd. Res<br />

kPa<br />

Heat Duty<br />

Watts<br />

LPHW<br />

Flow Rate<br />

l/s<br />

Hyd. Res.<br />

kPa<br />

Running<br />

Current (A)<br />

Power<br />

Absorbed (W)<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH6CH<br />

Specific <strong>Fan</strong><br />

Power (SFP)<br />

W/I/s<br />

109 Extra low 1494 1895 0.075 3.63 815 0.018 0.28 0.17 23 0.21<br />

122 Low 1667 2112 0.084 4.42 898 0.02 0.34 0.23 31 0.25<br />

143 Low + 1911 2392 0.095 5.55 984 0.022 0.4 0.27 41 0.29<br />

162 Medium 2129 2642 0.105 6.65 1060 0.024 0.46 0.4 55 0.34<br />

167 Medium + 2186 2707 0.107 6.95 1080 0.024 0.47 0.44 59 0.35<br />

175 High 2277 2812 0.112 7.45 1112 0.025 0.5 0.5 66 0.38<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH9CH<br />

152 Extra low 2093 2662 0.106 4.19 1200 0.027 0.7 0.23 30 0.20<br />

190 Low 2586 3269 0.13 6.1 1422 0.032 0.96 0.3 42 0.22<br />

221 Low + 2951 3693 0.147 7.62 1556 0.035 1.14 0.39 55 0.25<br />

274 Medium 3584 4438 0.176 10.67 1798 0.04 1.49 0.57 80 0.29<br />

282 Medium + 3675 4541 0.18 11.13 1829 0.041 1.54 0.62 86 0.30<br />

304 High 3923 4828 0.192 12.45 1914 0.043 1.67 0.74 104 0.34<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH12CH<br />

216 Extra low 3091 4016 0.159 9.92 1699 0.038 1.5 0.32 42 0.19<br />

235 Low 3326 4295 0.17 11.21 1784 0.04 1.65 0.4 54 0.23<br />

262 Low + 3659 4687 0.186 13.16 1904 0.042 1.86 0.5 67 0.26<br />

307 Medium 4210 5343 0.212 16.72 2102 0.047 2.23 0.7 93 0.30<br />

326 Medium + 4463 5658 0.225 18.57 2206 0.049 2.44 0.82 113 0.35<br />

335 High 4569 5783 0.229 19.33 2243 0.05 2.52 0.89 121 0.36<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH13CH<br />

236 Extra low 3353 4338 0.172 7.86 1934 0.043 2.15 0.34 45 0.19<br />

265 Low 3738 4817 0.191 9.52 2103 0.047 2.51 0.4 54 0.20<br />

317 Low + 4376 5572 0.221 12.45 2340 0.052 3.06 0.51 70 0.22<br />

363 Medium 4937 6239 0.248 15.32 2547 0.057 3.58 0.7 99 0.27<br />

381 Medium + 5184 6552 0.26 16.77 2658 0.059 3.87 0.78 110 0.29<br />

431 High 5774 7241 0.287 20.16 2863 0.064 4.45 1.06 143 0.33<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH15CH<br />

246 Extra low 3475 4480 0.178 6.57 2057 0.046 2.78 0.32 42 0.17<br />

280 Low 3980 5151 0.204 8.5 2336 0.052 3.52 0.37 49 0.18<br />

324 Low + 4589 5927 0.235 11.01 2625 0.058 4.36 0.47 65 0.20<br />

380 Medium 5282 6749 0.268 14 2886 0.064 5.2 0.64 90 0.24<br />

415 Medium + 5714 7265 0.288 16.04 3047 0.068 5.75 0.77 111 0.27<br />

440 High 6021 7633 0.303 17.57 3163 0.07 6.15 0.88 124 0.28<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH18CH<br />

350 Extra low 4901 6288 0.25 8.75 2971 0.066 6.61 0.47 60 0.17<br />

382 Low 5378 6921 0.275 10.46 3239 0.072 7.74 0.51 67 0.18<br />

449 Low + 6237 7966 0.316 13.59 3599 0.08 9.4 0.65 90 0.20<br />

538 Medium 7333 9277 0.368 18.06 4020 0.089 11.52 0.9 129 0.24<br />

585 Medium + 7910 9966 0.395 20.65 4241 0.094 12.71 1.01 142 0.24<br />

647 High 8703 10936 0.434 24.55 4566 0.102 14.55 1.24 177 0.27<br />

Based on following Design Condition:<br />

Return Air Temperature(summer): 23 o C db and 16.4 o C wb<br />

Chilled Water Temperature: 6/12 o C<br />

Return Air Temperature(winter): 21 o C<br />

LPHW Temperature: 82/71 o C<br />

External Static Pressure: 30Pa<br />

Electric heat is available on all units. For further information please contact us.<br />

For any alternative design conditions please contact the Cooling Department at <strong>Diffusion</strong>.


ACOUSTIC PERFORMANCE<br />

SOUND POWER LEVELS<br />

Model & Size<br />

Air Volume l/s<br />

Speed<br />

Acoustic Measuring Position<br />

OCTAVE BAND FREQUENCY<br />

63 125 250 500 1K 2K 4K<br />

NR<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH6CH<br />

109 Extra low<br />

122 Low<br />

143 Low +<br />

162 Medium<br />

167 Medium +<br />

175 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

42 48 43 45 34 28 25<br />

47 46 38 31 32 22 21<br />

41 49 45 47 37 31 29<br />

48 48 39 32 34 24 23<br />

43 51 47 49 40 34 32<br />

48 50 43 34 37 27 26<br />

46 52 49 51 41 37 35<br />

51 52 45 36 39 29 29<br />

45 53 49 51 42 37 36<br />

50 52 46 37 41 30 30<br />

47 54 52 54 44 39 36<br />

52 56 49 38 42 31 30<br />

28<br />

31<br />

33<br />

35<br />

36<br />

37<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH9CH<br />

152 Extra low<br />

190 Low<br />

221 Low +<br />

274 Medium<br />

282 Medium +<br />

304 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

47 48 43 44 34 27 21<br />

46 46 41 30 29 19 17<br />

46 49 45 47 37 30 25<br />

47 48 43 32 32 21 20<br />

49 51 47 49 39 33 28<br />

48 50 45 34 35 23 23<br />

46 53 50 52 43 38 34<br />

49 53 48 38 39 28 28<br />

46 54 51 53 44 39 35<br />

51 53 49 38 40 29 29<br />

47 55 53 54 45 40 37<br />

51 54 50 39 41 30 31<br />

28<br />

30<br />

32<br />

35<br />

36<br />

37<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH12CH<br />

216 Extra low<br />

235 Low<br />

262 Low +<br />

307 Medium<br />

326 Medium +<br />

335 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

45 48 43 45 33 27 22<br />

47 47 40 31 30 18 17<br />

48 49 46 48 36 30 26<br />

45 48 42 32 33 22 20<br />

45 51 48 50 39 33 29<br />

49 50 44 35 35 24 22<br />

47 52 51 51 41 36 34<br />

49 53 48 38 39 28 27<br />

48 54 53 53 44 38 36<br />

51 54 49 39 41 29 29<br />

48 54 53 54 44 39 37<br />

51 54 50 39 41 30 30<br />

28<br />

30<br />

33<br />

35<br />

36<br />

37<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH13CH<br />

236 Extra low<br />

265 Low<br />

317 Low +<br />

363 Medium<br />

381 Medium +<br />

431 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

48 49 45 45 34 27 22<br />

45 47 41 30 28 18 18<br />

47 50 46 47 36 29 24<br />

47 49 43 32 30 20 19<br />

48 52 48 49 38 32 28<br />

48 50 44 34 33 23 22<br />

48 54 51 52 42 35 32<br />

49 53 47 37 37 27 26<br />

51 55 53 53 43 37 34<br />

50 54 48 38 38 28 27<br />

52 56 54 54 45 39 37<br />

52 56 50 41 41 32 31<br />

28<br />

30<br />

32<br />

35<br />

36<br />

37<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH15CH<br />

246 Extra low<br />

280 Low<br />

324 Low +<br />

380 Medium<br />

415 Medium +<br />

440 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

45 50 45 45 33 26 21<br />

46 47 42 31 29 19 17<br />

44 51 46 46 34 28 22<br />

46 48 43 34 31 20 18<br />

44 52 48 49 37 30 26<br />

46 49 46 35 34 22 21<br />

46 53 49 50 40 31 27<br />

51 53 49 37 37 26 25<br />

52 55 53 53 43 37 34<br />

52 54 50 39 40 28 27<br />

52 56 53 54 44 38 36<br />

51 55 51 40 41 30 28<br />

28<br />

30<br />

32<br />

35<br />

37<br />

38<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong><br />

WH18CH<br />

350 Extra low<br />

382 Low<br />

449 Low +<br />

538 Medium<br />

585 Medium +<br />

647 High<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

INLET CASE RADIATED<br />

DISCHARGE<br />

52 48 46 44 35 26 20<br />

46 47 41 33 28 22 18<br />

52 49 47 45 35 28 22<br />

48 49 43 35 29 23 20<br />

50 50 49 47 37 31 25<br />

50 50 45 35 29 21 20<br />

52 53 52 51 41 35 31<br />

50 52 48 37 33 24 25<br />

51 55 53 52 42 36 33<br />

52 53 48 39 35 26 26<br />

51 55 54 53 44 38 35<br />

53 55 50 41 38 29 29<br />

28<br />

30<br />

32<br />

35<br />

36<br />

37<br />

OCTAVE BAND FREQUENCY<br />

63 125 250 500 1K 2K 4K<br />

CORR<strong>EC</strong>TIONS FOR DISCHARGE INDUCT<br />

8 4 1 0 0 0 0<br />

Correction to be added to Discharge only, to convert to Discharge Induct.<br />

The discharge sound power levels shown above are based on all front spigots connected directly to an unlined<br />

plenum/grilles and measurements taken 1.5m from grille at 45 o .<br />

The NR levels shown above are for guidance only and are based on a typical office layout. We would recommend<br />

that advice is taken from an Acoustic Consultant to verify actual project noise levels.<br />

To achieve guide NR35 it is recommended that a maximum velocity of 2.5m/s per outlet is not exceeded.


<strong>Highline</strong> <strong>260i</strong> <strong>EC</strong> <strong>Waterside</strong> <strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong><br />

UNIT A SPIGOTS<br />

(No Off)<br />

6 855 4<br />

9 1075 5<br />

12 1230 5<br />

13 1408 5<br />

15 1655 6<br />

18 2040 7<br />

R<strong>EC</strong>TANGULAR SPIGOTS<br />

ALSO AVAILABLE


Options<br />

• Underfloor installation available<br />

• Electric Heat(Stainless Steel sheathed element) with Thermal Cut-out<br />

• Differential Pressure Switch for heating element protection(Standard)<br />

• Current Switch for heating element protection(Optional)<br />

• Power Correction Module<br />

• Speed Controller/ Speed Limiter<br />

• 24v Transformer<br />

• Condensate pumps<br />

DIFFUSION <strong>Unit</strong> Coding System<br />

UNIT MODEL FAN TYPE CONTROL APPLICATION OPTIONS UNIT SIZE Chassis<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong> - Electronically commutated A - Airside H - Horizontal E - EL<strong>EC</strong>TRIC 06 CH<br />

W - <strong>Waterside</strong> UF - Underfloor CO - COOLING ONLY 09<br />

e.g.<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong>-W-H-09-CH<br />

HIGHLINE <strong>260i</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Horizontal, 4 pipe, size 9, chassis<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong>-W-UF-CO-09-CH<br />

HIGHLINE <strong>260i</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Underfloor, Cooling Only, size 9, chassis<br />

HIGHLINE <strong>260i</strong> <strong>EC</strong>-W-H-E-09-CH<br />

HIGHLINE <strong>260i</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Horizontal, 2 pipe, Electric Heat, size 9, chassis<br />

12<br />

13<br />

15<br />

18<br />

‘<br />

Established in 1960,<br />

<strong>Diffusion</strong> has over 40 years<br />

experience in producing<br />

environmental solutions<br />

via the manufacture of heating,<br />

air conditioning and<br />

ventilating products.<br />

‘<br />

<strong>Diffusion</strong> Environmental Systems<br />

47 Central Avenue, West Molesey, Surrey KT8 2QZ<br />

Tel: (+44) 020 8783 0033 Fax: (+44) 020 8783 0140<br />

Email: diffusion@etenv.co.uk www.diffusion-group.co.uk<br />

<strong>Diffusion</strong> Environmental Systems have a policy of continuous<br />

development. We therefore reserve the right to alter information<br />

contained in this leaflet, without prior notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!