LPCA 055-060-070-075-085-090-100-115 125-135-150-170HMB
LPCA 055-060-070-075-085-090-100-115 125-135-150-170HMB
LPCA 055-060-070-075-085-090-100-115 125-135-150-170HMB
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
F<br />
9.2 <strong>LPCA</strong> <strong>055</strong>-<strong>085</strong>HMB<br />
L1<br />
L2<br />
L3<br />
N<br />
SM1<br />
POWER CIRCUIT<br />
PE<br />
FCH<br />
FC1<br />
FC2<br />
FC3<br />
FC4<br />
FF1<br />
FF2<br />
CC1<br />
CC2<br />
CC3<br />
CC4<br />
CH1<br />
CH2<br />
CH3<br />
CH4<br />
CC1<br />
CC2<br />
CC3<br />
CC4<br />
CF1<br />
CF2<br />
CH1<br />
CH2<br />
CH3<br />
CH4<br />
R S<br />
VC<br />
T<br />
N<br />
U1<br />
V1 W1<br />
U2<br />
V2 W2<br />
U3<br />
V3 W3<br />
U4<br />
V4 W4<br />
UF1 VF1 WF1<br />
UF2 VF2 WF2<br />
N<br />
N<br />
N<br />
N<br />
CM1<br />
CM2<br />
CM3<br />
CM4<br />
SF1,2<br />
SF3,4<br />
LEGEND<br />
F1 CONTROL CIRCUIT BREAKER<br />
F2 LOW VOLTAGE (12 V AC) CIRCUIT BREAKER<br />
FF1 CIRCUIT 1 FANS CIRCUIT BREAKER<br />
FF2 CIRCUIT 2 FANS CIRCUIT BREAKER<br />
VC VOLTAGE SURVEYOR<br />
CC1 COMPRESSOR 1 CONTACTOR<br />
CC2 COMPRESSOR 2 CONTACTOR<br />
CC3 COMPRESSOR 3 CONTACTOR<br />
CC4 COMPRESSOR 4 CONTACTOR<br />
SV1 CIRCUIT 1 LIQUID LINE SOLENOID VALVE<br />
SV2 CIRCUIT 2 LIQUID LINE SOLENOID VALVE<br />
TC1 COMPRESSOR 1 THERMAL PROTECTION<br />
TC2 COMPRESSOR 2 THERMAL PROTECTION<br />
TC3 COMPRESSOR 3 THERMAL PROTECTION<br />
TC4 COMPRESSOR 4 THERMAL PROTECTION<br />
TF CONDENSER FANS THERMAL PROTECTION<br />
HP1 HIGH PRESSURE PRESSOSTAT CIRCUIT 1<br />
LP1 LOW PRESSURE PRESSOSTAT CIRCUIT 1<br />
HP2 HIGH PRESSURE PRESSOSTAT CIRCUIT 2<br />
LP2 LOW PRESSURE PRESSOSTAT CIRCUIT 2<br />
S1 ENTERING WATER TEMPERATURE SENSOR<br />
S2 LEAVING WATER TEMPERATURE SENSOR<br />
S3 CIRCUIT 1 COIL TEMPERATURE SENSOR<br />
S4 CIRCUIT 2 COIL TEMPERATURE SENSOR<br />
TR1 TRANSFORMER 220/12V AC<br />
SM1 GENERAL CIRCUIT BREAKER<br />
CM1 COMPRESSOR 1 (CIRCUIT 1)<br />
CM2 COMPRESSOR 2 (CIRCUIT 1)<br />
CM3 COMPRESSOR 3 (CIRCUIT 2)<br />
CM4 COMPRESSOR 4 (CIRCUIT 2)<br />
FC1 COMPRESSOR 1 CIRCUIT BREAKER<br />
FC2 COMPRESSOR 2 CIRCUIT BREAKER<br />
FC3 COMPRESSOR 3 CIRCUIT BREAKER<br />
FC4 COMPRESSOR 4 CIRCUIT BREAKER<br />
FCH COMPRESSORS CRANKCASE HEATERS<br />
CIRCUIT BREAKER<br />
CH1 CRANKCASE HEATER COMPRESSOR 1<br />
CH2 CRANKCASE HEATER COMPRESSOR 2<br />
CH3 CRANKCASE HEATER COMPRESSOR 3<br />
CH4 CRANKCASE HEATER COMPRESSOR 4<br />
CF1 CIRCUIT 1 FANS CONTACTOR<br />
CF2 CIRCUIT 2 FANS CONTACTOR<br />
SF1,2 CIRCUIT 1 FANS<br />
SF3,4 CIRCUIT 2 FANS<br />
4V1 4-WAY VALVE CIRCUIT 1<br />
4V2 4-WAY VALVE CIRCUIT 2<br />
ALARM<br />
E00: REMOTE OFF IN POSITION OFF<br />
E01: HIGH PRESSURE CIRCUIT 1 OR CIRCUIT 1 FANS THERMAL PROTECTION<br />
E02: LOW ORESSURE CIRCUIT 1<br />
E03: THERMAL SWITCH PROTECTION COMP.1<br />
E06: SENSOR ST2 FAULT<br />
E07: SENSOR ST3 FAULT<br />
E13: THERMAL SWITCH PROTECTION COMP. 2<br />
E23: THERMAL SWITCH PROTECTION COMP. 3<br />
E33: THERMAL SWITCH PROTECTION COMP. 4<br />
E21: HIGH PRESSURE CIRCUIT 2 OR CIRCUIT 2 FANS THERMAL PROTECTION<br />
E22: LOW PRESSURE CIRCUIT 2<br />
E27: SENSOR ST6 FAULT<br />
E40: SENSOR ST1 FAULT<br />
E41: FLOW SWITCH OR PUMP THERMAL PROTECTION<br />
FIELD CONNECTIONS<br />
220 V AC<br />
C<br />
P<br />
T<br />
H<br />
SW<br />
ON<br />
OFF<br />
S<br />
W<br />
AL<br />
AL<br />
C-P PUMP COMMAND (220 V AC)<br />
T-H PUMP THERMAL PROTECTION<br />
F-SW DIFFERENTIAL WATER PRESSURE SWITCH<br />
ON-OFF REMOTE ON-OFF SWITCH<br />
AL-AL ALARM SIGNAL (N.O. CONTACT)<br />
S-W REMOTE SUMMER-WINTER SWITCH<br />
220 V AC<br />
PUMP COMMAND (220 V AC)<br />
PUMP THERMAL PROTECTION<br />
DIFFERENTIAL WATER PRESSURE SWITCH<br />
REMOTE SWITCH ON-OFF<br />
REMOTE SUMMER -WINTER<br />
ALARM SIGNAL (N.O. CONTACT)<br />
ENTERING WATER TEMP.SENSOR (ST1)<br />
LEAVING WATER TEMP. SENSOR (ST2)<br />
CIRCUIT 1 COIL TEMPERATURE SENSOR (ST3)<br />
CIRCUIT 2 COIL TEMPERATURE SENSOR (ST4)<br />
CIRCUIT 1 FANS THERMAL PROTECTION<br />
CIRCUIT 2 FANS THERMAL PROTECTION<br />
COMPRESSOR 1 THERMAL PROTECTION<br />
COMPRESSOR 2 THERMAL PROTECTION<br />
COMPRESSOR 3 THERMAL PROTECTION<br />
COMPRESSOR 4 THERMAL PROTECTION<br />
HIGH PRESSURE PRESSOSTAT CIRCUIT 1<br />
LOW PRESSURE PRESSOSTAT CIRCUIT 1<br />
HIGH PRESSURE PRESSOSTAT CIRCUIT 2<br />
LOW PRESSURE PRESSOSTAT CIRCUIT 2<br />
220 V FOR THERMAL PROTECTION COMP. 1<br />
220 V FOR THERMAL PROTECTION COMP. 2<br />
CIRCUIT 1 SOLENOID VALVE<br />
CRANKCASE HEATER COMPRESSOR 1<br />
CRANKCASE HEATER COMPRESSOR 2<br />
4-WAY REVERSING VALVE CIRCUIT1<br />
220 V FOR THERMAL PROTECTION COMP. 3<br />
220 V FOR THERMAL PROTECTION COMP. 4<br />
CIRCUIT 2 SOLENOID VALVE<br />
CRANKCASE HEATER COMPRESSOR 3<br />
CRANKCASE HEATER COMPRESSOR 4<br />
SW<br />
ON<br />
OFF<br />
S<br />
W<br />
F2<br />
C1<br />
C<br />
P<br />
T<br />
H<br />
F<br />
AL<br />
AL<br />
S<br />
F1<br />
T<br />
T<br />
T<br />
C2<br />
1<br />
S<br />
2<br />
S<br />
3<br />
S<br />
4<br />
T<br />
T<br />
C3<br />
T<br />
C4<br />
H<br />
P1<br />
L<br />
P1<br />
H<br />
P2<br />
L<br />
P2<br />
LTC1<br />
LTC2<br />
SV1<br />
CH1<br />
CH2<br />
4V1<br />
LTC3<br />
LTC4<br />
SV2<br />
CH3<br />
CH4<br />
4V2<br />
N<br />
SV1 4V1 SV2 4V2<br />
4-WAY REVERSING VALVE CIRCUIT 2<br />
Interklima Hydronic systems<br />
<strong>LPCA</strong> <strong>055</strong>-<strong>170HMB</strong> ñ R407c/Tandem Scroll 17