F<br />

9.2 <strong>LPCA</strong> <strong>055</strong>-<strong>085</strong>HMB<br />

L1<br />

L2<br />

L3<br />

N<br />

SM1<br />

POWER CIRCUIT<br />

PE<br />

FCH<br />

FC1<br />

FC2<br />

FC3<br />

FC4<br />

FF1<br />

FF2<br />

CC1<br />

CC2<br />

CC3<br />

CC4<br />

CH1<br />

CH2<br />

CH3<br />

CH4<br />

CC1<br />

CC2<br />

CC3<br />

CC4<br />

CF1<br />

CF2<br />

CH1<br />

CH2<br />

CH3<br />

CH4<br />

R S<br />

VC<br />

T<br />

N<br />

U1<br />

V1 W1<br />

U2<br />

V2 W2<br />

U3<br />

V3 W3<br />

U4<br />

V4 W4<br />

UF1 VF1 WF1<br />

UF2 VF2 WF2<br />

N<br />

N<br />

N<br />

N<br />

CM1<br />

CM2<br />

CM3<br />

CM4<br />

SF1,2<br />

SF3,4<br />

LEGEND<br />

F1 CONTROL CIRCUIT BREAKER<br />

F2 LOW VOLTAGE (12 V AC) CIRCUIT BREAKER<br />

FF1 CIRCUIT 1 FANS CIRCUIT BREAKER<br />

FF2 CIRCUIT 2 FANS CIRCUIT BREAKER<br />

VC VOLTAGE SURVEYOR<br />

CC1 COMPRESSOR 1 CONTACTOR<br />

CC2 COMPRESSOR 2 CONTACTOR<br />

CC3 COMPRESSOR 3 CONTACTOR<br />

CC4 COMPRESSOR 4 CONTACTOR<br />

SV1 CIRCUIT 1 LIQUID LINE SOLENOID VALVE<br />

SV2 CIRCUIT 2 LIQUID LINE SOLENOID VALVE<br />

TC1 COMPRESSOR 1 THERMAL PROTECTION<br />

TC2 COMPRESSOR 2 THERMAL PROTECTION<br />

TC3 COMPRESSOR 3 THERMAL PROTECTION<br />

TC4 COMPRESSOR 4 THERMAL PROTECTION<br />

TF CONDENSER FANS THERMAL PROTECTION<br />

HP1 HIGH PRESSURE PRESSOSTAT CIRCUIT 1<br />

LP1 LOW PRESSURE PRESSOSTAT CIRCUIT 1<br />

HP2 HIGH PRESSURE PRESSOSTAT CIRCUIT 2<br />

LP2 LOW PRESSURE PRESSOSTAT CIRCUIT 2<br />

S1 ENTERING WATER TEMPERATURE SENSOR<br />

S2 LEAVING WATER TEMPERATURE SENSOR<br />

S3 CIRCUIT 1 COIL TEMPERATURE SENSOR<br />

S4 CIRCUIT 2 COIL TEMPERATURE SENSOR<br />

TR1 TRANSFORMER 220/12V AC<br />

SM1 GENERAL CIRCUIT BREAKER<br />

CM1 COMPRESSOR 1 (CIRCUIT 1)<br />

CM2 COMPRESSOR 2 (CIRCUIT 1)<br />

CM3 COMPRESSOR 3 (CIRCUIT 2)<br />

CM4 COMPRESSOR 4 (CIRCUIT 2)<br />

FC1 COMPRESSOR 1 CIRCUIT BREAKER<br />

FC2 COMPRESSOR 2 CIRCUIT BREAKER<br />

FC3 COMPRESSOR 3 CIRCUIT BREAKER<br />

FC4 COMPRESSOR 4 CIRCUIT BREAKER<br />

FCH COMPRESSORS CRANKCASE HEATERS<br />

CIRCUIT BREAKER<br />

CH1 CRANKCASE HEATER COMPRESSOR 1<br />

CH2 CRANKCASE HEATER COMPRESSOR 2<br />

CH3 CRANKCASE HEATER COMPRESSOR 3<br />

CH4 CRANKCASE HEATER COMPRESSOR 4<br />

CF1 CIRCUIT 1 FANS CONTACTOR<br />

CF2 CIRCUIT 2 FANS CONTACTOR<br />

SF1,2 CIRCUIT 1 FANS<br />

SF3,4 CIRCUIT 2 FANS<br />

4V1 4-WAY VALVE CIRCUIT 1<br />

4V2 4-WAY VALVE CIRCUIT 2<br />

ALARM<br />

E00: REMOTE OFF IN POSITION OFF<br />

E01: HIGH PRESSURE CIRCUIT 1 OR CIRCUIT 1 FANS THERMAL PROTECTION<br />

E02: LOW ORESSURE CIRCUIT 1<br />

E03: THERMAL SWITCH PROTECTION COMP.1<br />

E06: SENSOR ST2 FAULT<br />

E07: SENSOR ST3 FAULT<br />

E13: THERMAL SWITCH PROTECTION COMP. 2<br />

E23: THERMAL SWITCH PROTECTION COMP. 3<br />

E33: THERMAL SWITCH PROTECTION COMP. 4<br />

E21: HIGH PRESSURE CIRCUIT 2 OR CIRCUIT 2 FANS THERMAL PROTECTION<br />

E22: LOW PRESSURE CIRCUIT 2<br />

E27: SENSOR ST6 FAULT<br />

E40: SENSOR ST1 FAULT<br />

E41: FLOW SWITCH OR PUMP THERMAL PROTECTION<br />

FIELD CONNECTIONS<br />

220 V AC<br />

C<br />

P<br />

T<br />

H<br />

SW<br />

ON<br />

OFF<br />

S<br />

W<br />

AL<br />

AL<br />

C-P PUMP COMMAND (220 V AC)<br />

T-H PUMP THERMAL PROTECTION<br />

F-SW DIFFERENTIAL WATER PRESSURE SWITCH<br />

ON-OFF REMOTE ON-OFF SWITCH<br />

AL-AL ALARM SIGNAL (N.O. CONTACT)<br />

S-W REMOTE SUMMER-WINTER SWITCH<br />

220 V AC<br />

PUMP COMMAND (220 V AC)<br />

PUMP THERMAL PROTECTION<br />

DIFFERENTIAL WATER PRESSURE SWITCH<br />

REMOTE SWITCH ON-OFF<br />

REMOTE SUMMER -WINTER<br />

ALARM SIGNAL (N.O. CONTACT)<br />

ENTERING WATER TEMP.SENSOR (ST1)<br />

LEAVING WATER TEMP. SENSOR (ST2)<br />

CIRCUIT 1 COIL TEMPERATURE SENSOR (ST3)<br />

CIRCUIT 2 COIL TEMPERATURE SENSOR (ST4)<br />

CIRCUIT 1 FANS THERMAL PROTECTION<br />

CIRCUIT 2 FANS THERMAL PROTECTION<br />

COMPRESSOR 1 THERMAL PROTECTION<br />

COMPRESSOR 2 THERMAL PROTECTION<br />

COMPRESSOR 3 THERMAL PROTECTION<br />

COMPRESSOR 4 THERMAL PROTECTION<br />

HIGH PRESSURE PRESSOSTAT CIRCUIT 1<br />

LOW PRESSURE PRESSOSTAT CIRCUIT 1<br />

HIGH PRESSURE PRESSOSTAT CIRCUIT 2<br />

LOW PRESSURE PRESSOSTAT CIRCUIT 2<br />

220 V FOR THERMAL PROTECTION COMP. 1<br />

220 V FOR THERMAL PROTECTION COMP. 2<br />

CIRCUIT 1 SOLENOID VALVE<br />

CRANKCASE HEATER COMPRESSOR 1<br />

CRANKCASE HEATER COMPRESSOR 2<br />

4-WAY REVERSING VALVE CIRCUIT1<br />

220 V FOR THERMAL PROTECTION COMP. 3<br />

220 V FOR THERMAL PROTECTION COMP. 4<br />

CIRCUIT 2 SOLENOID VALVE<br />

CRANKCASE HEATER COMPRESSOR 3<br />

CRANKCASE HEATER COMPRESSOR 4<br />

SW<br />

ON<br />

OFF<br />

S<br />

W<br />

F2<br />

C1<br />

C<br />

P<br />

T<br />

H<br />

F<br />

AL<br />

AL<br />

S<br />

F1<br />

T<br />

T<br />

T<br />

C2<br />

1<br />

S<br />

2<br />

S<br />

3<br />

S<br />

4<br />

T<br />

T<br />

C3<br />

T<br />

C4<br />

H<br />

P1<br />

L<br />

P1<br />

H<br />

P2<br />

L<br />

P2<br />

LTC1<br />

LTC2<br />

SV1<br />

CH1<br />

CH2<br />

4V1<br />

LTC3<br />

LTC4<br />

SV2<br />

CH3<br />

CH4<br />

4V2<br />

N<br />

SV1 4V1 SV2 4V2<br />

4-WAY REVERSING VALVE CIRCUIT 2<br />

Interklima Hydronic systems<br />

<strong>LPCA</strong> <strong>055</strong>-<strong>170HMB</strong> ñ R407c/Tandem Scroll 17