Technical appendix<br />

1. Basic technical requirements<br />

All equipment and components in this catalogue meet, unless<br />

otherwise stated, the European standards for “Cable networks<br />

for television signals, sound signals and interactive services”<br />

from the standardization organization CENELEC, which have<br />

been adopted in national versions.<br />

EN 50083-1 Safety requirements<br />

EN 50083-1/A1<br />

EN 50083-1/A2<br />

EN 50083-2 Electromagnetic compatibility (EMC)<br />

of equipment<br />

The equipment conforms to the uniform European “EMC<br />

directive” in accordance with legal requirements. For the majority<br />

of the product groups in this catalogue, EN 50083-2<br />

is relevant. In relation to the “Low voltage directive”, EN 60065<br />

is the basis to which reference is made in EN 50083-1<br />

“Safety requirements”.<br />

The CE marking for products in relation to EMC and the low<br />

voltage directive is based on these standards.<br />

In addition, CENELEC committee TC 209 has ratified European<br />

standards for equipment and system requirements for “Cable<br />

networks for television signals, sound signals and interactive<br />

services”.<br />

EN 50083-3<br />

EN 50083-4<br />

EN 50083-5<br />

EN 50083-6<br />

EN 50083-7<br />

EN 50083-8<br />

EN 50083-9<br />

EN 50083-10<br />

Active broadband equipment for coaxial<br />

cable networks<br />

Passive broadband equipment for coaxial<br />

cable networks<br />

Headend equipment<br />

Optical equipment<br />

System requirements<br />

Electromagnetic compatibility of cable<br />

networks<br />

Interfaces for CATV/SMATV headends<br />

and similar professional equipment for<br />

DVB/MPEG-2 transport streams<br />

System performance for return paths<br />

The system and equipment requirements are matched to each<br />

other in such a way that the minimum requirements for signal<br />

quality at the subscriber’s outlet can be met with a minimum<br />

of technical effort. In addition, requirements that result from<br />

use of both analogue and digital signal transmission have also<br />

been taken into account. The EN 50083 standards provide the<br />

network operator, planner and installer with concrete<br />

guidelines for network design and selection of appropriate<br />

network components. Hirschmann network components are<br />

developed to these standards and are marked in the catalogue<br />

by the relevant EN standard. The equipment standards<br />

(EN 50083 Parts 3...6) include fulfillment of the safety and EMC<br />

requirements (EN 50083 Parts 1 + 2).<br />

The legally required CE marking for antenna and<br />

telecommunication products refers to adherence to<br />

electromagnetic compatibility (EMC) limits and, from 1 Jan.<br />

1997, to adherence to the low voltage directive.<br />

The CE marking does thus not imply fulfilment of the product<br />

and system requirements according to EN 50083- 3...-10.<br />

For this reason Triax indicates compliance with these basic<br />

requirements on equipment (EN 50083-3...6) by explicitly<br />

noting the corresponding EN standard in the catalogue and in<br />

the operating instructions.<br />

1.1 Marking of components for TV cable networks<br />

With the CE marking Triax confirms the compliance of its<br />

products with the applicable EU directives (currently EMC and<br />

low voltage directives) as well as with the standards EN 50083-<br />

1, EN 50083-2 and EN 60065. For receivers the standards EN<br />

55013, EN 55020 and EN 61000 are applied.<br />

The CE marking is placed on the product, on the packaging<br />

and/or included in the operating instructions.<br />

To prevent interference between TV cable networks and radio<br />

services, it is necessary to use components with sufficient<br />

shielding. Due to the varying conditions in the European<br />

countries, the shielding rate was defined in the European<br />

standard EN 50083-2 in two stages, the high quality class A<br />

and class B with reduced shielding rate values.<br />

For example, the high radio density present in<br />

many parts of the world makes the usage of class<br />

A equipment necessary to prevent interactions,<br />

particularly with safety-relevant radio services<br />

such as air traffic control. As a differentiation in<br />

the appearance of the equipment for trade and<br />

installers is not possible, Triax and the other<br />

companies in the Fachverband<br />

Empfangsantennen- und Breitbandverteiltechnik<br />

im Zentral verband Elektrotechnik- und<br />

Elektroindustrie (ZVEI) e. V. mark the products<br />

with the protected trademark-symbol shown.<br />

In this way the higher quality of the equipment is<br />

made clear.<br />

(See 3.3 Shielding rate)<br />

For compliance with the legal EMC requirements for TV cable<br />

networks, we expressly recommend the usage of class A<br />

components, including connecting cables so marked for<br />

terminal equipment.<br />

Protection class 2 according to IEC 60417-5172<br />

for components with power connection 230 V ~.<br />