Triax IFM indoor multiband amplifiers<br />
Low noise multi-range amplifiers with digital capability<br />
• 4 highly selective range inputs and one output<br />
• You can select operationrange by use of integrated jumper<br />
• Level controller 0...-20 dB at each input<br />
• Low power consumption<br />
• Low-noise inputs for DVB-T<br />
• Die-cast housing with cooling fins for reducing temperature<br />
• F-connectors<br />
IFM amplifier housing<br />
Technical data on IFM series<br />
Type<br />
IFM 120<br />
IFM 130<br />
IFM 135<br />
Art. No.<br />
Frequency range<br />
Input 1 - UHF (1)<br />
Input 2 - VHF III<br />
Input 3 - VHF I<br />
- UHF (2)<br />
Input 4 - FM<br />
- VHF I<br />
Input 1 + 2<br />
Combined with jumpers<br />
MHz<br />
MHz<br />
MHz<br />
MHz<br />
MHz<br />
MHz<br />
MHz<br />
MHz<br />
339120<br />
470-862<br />
174-230<br />
-<br />
-<br />
87.5-108 and<br />
47-68<br />
470-862 and<br />
174-230<br />
339130<br />
470-862<br />
174-230<br />
47-68<br />
-<br />
87.5-108<br />
-<br />
470-862 and<br />
174-230<br />
339135<br />
470-862<br />
174-230<br />
-<br />
470-862<br />
87.5-108 and<br />
47-68<br />
470-862 and<br />
174-230<br />
Gain (w. level controller 0 dB)<br />
Input 1 - UHF (1)<br />
Input 2 - VHF III<br />
Input 3 - VHF I<br />
- UHF (2)<br />
Input 4 - FM - VHF I<br />
dB<br />
dB<br />
dB<br />
dB<br />
dB<br />
22<br />
20<br />
-<br />
-<br />
20<br />
31<br />
30<br />
30<br />
-<br />
30<br />
35<br />
34<br />
-<br />
35<br />
34<br />
Level controller at all inputs dB 0...-20 0...-20 0...-20<br />
Noise figure (w. level controller 0 dB)<br />
Input 1 - UHF (1)<br />
Input 2 - VHF III<br />
Input 3 - VHF I<br />
- UHF (2)<br />
Input 4 - FM - VHF I<br />
Output level<br />
IMA3 ≥ 60 dB acc. EN 500873-5<br />
IMA2 ≥ 60 dB acc. EN 500873-3<br />
dB<br />
dB<br />
dB<br />
dB<br />
dB<br />
dBµV<br />
dBµV<br />
RF connectors (75 Ohm)<br />
Input / Output F-female F-female F-female<br />
Operating conditions acc. EN 60065<br />
Supply voltage V 230 / ±10% 230 / ±10% 230 / ±10%<br />
Power consumption W 3.5 6 7.5<br />
Operating temperature °C -25...+55 -25...+55 -25...+55<br />
Protection class II II II<br />
Degree of protection IP 20 20 20<br />
Screening acc. EN 50083-2 class A class A class A<br />
Dimensions W x H x D mm 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50<br />
Weight kg 0.68 0.68 0.68<br />
Packing unit<br />
1 pcs. carton box 1 pcs. carton box 1 pcs. carton box<br />
Reference standards<br />
Product standards/safety/EMC<br />
RoHS 2002/95/EG compliant<br />
4<br />
4<br />
-<br />
-<br />
4<br />
113<br />
102<br />
4<br />
4<br />
-<br />
-<br />
4<br />
115<br />
105<br />
7<br />
5<br />
-<br />
7<br />
5<br />
121<br />
110<br />
EN 50083-3 - Class 2 / EN 50083-1; EN 60065 / EN 50083-2<br />
Yes<br />
118