METRO 0.5 to 1.5<br />

Option 11<br />

Implosion filter option<br />

11 Option<br />

11.1 Implosion filter option<br />

The implosion filter prevents the entry of dust into the unit and prevents the release of dust into the<br />

environment.<br />

11.1.1 Intervals for inspections, maintenance and cleaning work<br />

Monthly<br />

Component Activity Target value/Meaning Qualification<br />

Implosion filter for damage and clean See "Maintenance work" on<br />

Page 43<br />

Seal for damage See "Maintenance work" on<br />

Page 43<br />

Operator<br />

Operator<br />

11.1.2 Maintenance work<br />

Fig. 11.1 – Implosion filter<br />

[1] Nut<br />

[2] Sealing ring<br />

[3] Cover plate of implosion filter<br />

[4] Implosion filter<br />

[5] Spacer<br />

[6] Seal<br />

[7] Cable passage<br />

[8] Plug connector<br />

Prepare the hopper <strong>loader</strong> for maintenance (see "Before starting work" on Page 32).<br />

Check the implosion filter (visual check) for damage.<br />

Check the cable passage gland for damage.<br />

Check the seal for damage.<br />

Edition: November 2005 43