DIN Safety Data Sheet<br />

1. Product PMMA XT<br />

1.1 Chemical Characterization Acrylic Polymer based on Methylmethacrylate<br />

1.2 Form Sheets<br />

1.3 <strong>Co</strong>lour <strong>Co</strong>lourless (transparent)<br />

1.4 Odour Odourless<br />

2. Physical data and safety data<br />

2.1 Change in Physical State Softening temperature about 102°C<br />

2.2 Density (20°C) 1.19 g/cm³<br />

2.3 Vapour Pressure Not applicable<br />

2.4 Vicosity Not applicable<br />

2.5 Solubility in Water Insoluble<br />

2.6 pH value not applicable<br />

2.7 Flash point 390°C (ASTM-D 1929-68)<br />

2.8 Ignition Temperature 465°C (ASTM-D 1929-68)<br />

2.9 Explosion Limits Not applicable<br />

2.10 Thermal Decomposition About 280°C<br />

2.11 Hazardous Decomposition With proper handling – none.<br />

On thermal decomposition vapours, consisting<br />

predominantly of Methylmethacrylate, are formed,<br />

which are inflammable and irritating to the eyes and<br />

respiratory system.<br />

<strong>Igepa</strong> <strong>group</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>KG</strong>, <strong>Sachsenfeld</strong> 4 D-<strong>20097</strong> <strong>Hamburg</strong>, phone +49-40-72 77 88-0, fax +49-40-72 77 88-50, info@igepa<strong>group</strong>.com, www.igepa<strong>group</strong>.com


DIN Safety Data Sheet<br />

2.12 Hazardous reaction With proper handling – none<br />

2.13 Further information None<br />

-------------------------------------------------------------------------------------------------------<br />

3. Transport<br />

GGV See/IMDG’ <strong>Co</strong>de not applicable<br />

UN No “ “<br />

ICAD/IATA-DGr “ “<br />

GGVE/GGVS “ “<br />

RID/ADR “ “<br />

ADNR “ “<br />

-------------------------------------------------------------------------------------------------------<br />

4. Regulations<br />

PMMA XT colourless does not require labeling<br />

as specified in EEC Directive 79/831/EEC and<br />

amendments.<br />

5. Protective Measures, Storage and Handling<br />

5.1 Technical Protective Measures With normal handling no special measures are<br />

necessary.<br />

Protective measures should be taken when machining<br />

including using a suction device for dust and chips.<br />

5.2 Personal Protective Equipment<br />

Respiratory protection<br />

Eye protection<br />

Hand protection<br />

Other<br />

None on normal handling<br />

On machining it may be necessary to use a dust mask.<br />

Safety glasses during machining<br />

Not required<br />

None<br />

5.3 Industrial Hygiene Observe usual standards of industrial hygiene<br />

5.4 Protection against Fire<br />

& Explosion<br />

No special measures necessary.<br />

5.5 Disposal Product may be disposed of together with household<br />

refuse or industrial refuse taking care to follow local<br />

authorities regulations.<br />

<strong>Igepa</strong> <strong>group</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>KG</strong>, <strong>Sachsenfeld</strong> 4 D-<strong>20097</strong> <strong>Hamburg</strong>, phone +49-40-72 77 88-0, fax +49-40-72 77 88-50, info@igepa<strong>group</strong>.com, www.igepa<strong>group</strong>.com


DIN Safety Data Sheet<br />

-------------------------------------------------------------------------------------------------------<br />

6. Measures to be taken in case of Accidents and Fires.<br />

6.1 Spillage/Leakage Vacuum and dispose of as written above<br />

6.2 Suitable Extinguishing Equipment Water-spray, foams, carbon dioxide, dry chemical<br />

Not to be Used Direct Water Jet<br />

6.3<br />

First Aid<br />

Upon irritation of the eyes – wash eyes with plenty of<br />

tap water for about 15 minutes.<br />

If<br />

irritation persists consult a doctor.<br />

6.4 Further Information None<br />

7. Toxicity<br />

-------------------------------------------------------------------------------------------------------<br />

PMMA XT is not to be regarded as a hazardous<br />

material.<br />

With proper handling and provided the standards of<br />

industrial hygiene and safety in the work place are<br />

followed, no health hazards should be expected.<br />

8. Ecological Effects<br />

PMMA XT is a solid material, insoluble in water and<br />

non-toxic, therefore no adverse effects on the<br />

environment should be expected.<br />

This information reflects our current knowledge. It serves to describe the product and cannot<br />

be interpreted as a guarantee of certain properties.<br />

<strong>Igepa</strong> <strong>group</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>KG</strong>, <strong>Sachsenfeld</strong> 4 D-<strong>20097</strong> <strong>Hamburg</strong>, phone +49-40-72 77 88-0, fax +49-40-72 77 88-50, info@igepa<strong>group</strong>.com, www.igepa<strong>group</strong>.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!