1 2 3 COMMUNICATION INTERFACES> ETHERNET CONVERTERS Z-BRIDGE ModBUS RTU 10..40 Vdc / 19..28 Vac Power Supply Output ModBUS TCP-IP Z-BRIDGE is a transparent ModBUS TCP/IP bridge for any ModBUS RTU serial device. It disposes of N.4 serial ports, either RS485 and RS232, master or slave. On Ethernet side is available a 10 Base-t port. The communication through Ethernet is protected by a galvanic isolation at 1500 V. MODBUS TCP -IP TECHNICAL SPECIFICATIONS General Data Power supply 10..40 Vdc / 19..28 Vac Power Consumption 3,5 W Isolation 1.500 Vac (3 way) Ethernet transmission Status Indicator Power Supply Ethernet connection Protection Degree IP20 Operating Temperature 0..+55 °C Dimension (W x H x D) 17,5 x 100 x 112 mm Weight 250 g Enclosure PBT Connections Removable terminal block, max wire size 2,5 mm 2 Mounting 35 mm DIN rail guide Communication, Memory Process N° 1 RS232 port N° 2 RS485 port Interfaces N° 1 RS232/RS485 port N°1 Ethernet port (server, 10 Mbps, http, ftp) ModBUS RTU master Protocol ModBUS TCP Memory CPU 32 bit, 512 kB flash, 256 kB RAM, backup battery Configuration Programming Standard Approvals Norms Z-NET3 (free software) CE EN50081-2; EN 55011; EN 50082-2; EN 61000-2-2; EN 50140/141; EN 61010- 1; EN 60742; APPLICATION NOTE ORDER CODES Code Z-BRIDGE Z-BRIDGE ModBUS ТСР 10/100 ModBUS ТСР Slave Ethernet 4 5 6 POWER Z-GW-MB 7 8 9 10 11 12 ModBUS RTU 115.200 У о ModBUS RTU Slave ModBUS RTU Slave Description Modbus RTU / Modbus TCP-IP bridge (Multiple serial port), 10..40 Vdc / 19..28 Vac ACCESSORIES & SOFTWARE Z-PC-DIN Z-SUPPLY Z-NET3 Backplane for power & bus Z-PC system configurator, IEC Switching power supply communication 61131 based pg. 36 pg. 36 pg. 36 SIMILAR PRODUCTS Z-GW-MB Z-LWS Z107E Modbus RTU Master to Ethernet - RS232/RS485 Micro PLC Modbus TCP gateway / server Adapter pg. 43 pg. 40 pg. 44 42
COMMUNICATION INTERFACES> ETHERNET CONVERTERS Z-GW-MB 12..40 Vdc / 19..28 Vac Power Supply ModBUS TCP-IP Z-GW-MB is a transparent ModBUS TCP/IP bridge for any ModBUS RTU serial device. It disposes of N.1 serial port, either RS485 and RS232, master or slave. On Ethernet side is available a 10 Base-t port. The communication through Ethernet is protected by a galvanic isolation at 1500 V MODBUS TCP -IP TECHNICAL SPECIFICATIONS General Data Power supply 12..28 Vac / 12..40 Vdc / 50-60 Hz Power consumption 1,2 W Isolation 500 Vac Power transducers - Status Indicators Power supply, Ethernet link, Ethernet connection Protection Degree IP20 Operating Temperature -20..+70 °C Dimension (W x H x D) 17.5 x 100 x 112 mm Mounting 35 mm DIN rail guide Communication, Memory Process Master mode for the RS485 or RS232 communication port with Communication ports ModbusRTU protocol Maximum baud rate for ModbusRTU set to 115200 bps Ethernet to RS232 or RS485 for remote control of the ModbusRTU Ethernet device. communication 10-BaseT Ethernet port (10 Mbit / S) Connection on RS485 Removable screw terminal ( M4, M5, M6) or IDC10 (rear connector) port Connection on RS232 DB9-F in the side of the module port Memory RJ45 front Standard Approvals CE Norms EN 61000-6-4/2002, EN 61000-6-2/2002, EN 61010, EN 60742 APPLICATION NOTE ORDER CODES Z-GW-MB Z-GW-MB Code Description Z-GW-MB Modbus RTU / Modbus TCP-IP bridge (single serial port), 12..40 Vdc / 12..28 Vac ACCESSORIES & SOFTWARE Z-PC-DIN Z-SUPPLY Backplane for power & bus communication Switching power supply pg. 36 pg. 36 SIMILAR PRODUCTS Z-BRIDGE Z-LWS Z107E Modbus RTU / Modbus TCP-IP Ethernet - RS232/RS485 Micro PLC bridge (Four serial port) Adapter pg. 42 pg. 40 pg. 44 43
- Page 1 and 2: www.seneca.it PRODUCT CATALOG
- Page 3 and 4: PRODUCT CATALOG/INDEX 1 2 3 4 I/O M
- Page 5: PRODUCT CATALOG/INDEX 7.3 Temperatu
- Page 8 and 9: I/O ModBUS SYSTEMS Z-PC LINE Z-PC L
- Page 10 and 11: I/O SYSTEMS> MODBUS DISTRIBUTED I/O
- Page 12 and 13: I/O SYSTEMS> MODBUS DISTRIBUTED I/O
- Page 14 and 15: I/O SYSTEMS> MODBUS DISTRIBUTED I/O
- Page 16 and 17: I/O SYSTEMS> MODBUS DISTRIBUTED I/O
- Page 18 and 19: I/O SYSTEMS > MODBUS DISTRIBUTED I/
- Page 20 and 21: I/O SYSTEMS > MODBUS DISTRIBUTED I/
- Page 22 and 23: I/O SYSTEMS > MODBUS DISTRIBUTED I/
- Page 24 and 25: I/O SYSTEMS > MODBUS DISTRIBUTED I/
- Page 26 and 27: I/O SYSTEMS > CANOPEN DISTRIBUTED I
- Page 28 and 29: I/O SYSTEMS > CANOPEN DISTRIBUTED I
- Page 30 and 31: I/O SYSTEMS > CANOPEN DISTRIBUTED I
- Page 32 and 33: I/O SYSTEMS > CANOPEN DISTRIBUTED I
- Page 34 and 35: I/O SYSTEMS > CANOPEN DISTRIBUTED I
- Page 36 and 37: I/O SYSTEMS > MODBUS DISTRIBUTED I/
- Page 38 and 39: CPU > MULTIFUNCTION CONTROL UNITS >
- Page 40 and 41: CPU > MULTIFUNCTION CONTROL UNITS >
- Page 44 and 45: COMMUNICATION INTERFACES> ETHERNET
- Page 46 and 47: COMMUNICATION INTERFACES> A/D CONVE
- Page 48 and 49: COMMUNICATION INTERFACES> SERIAL CO
- Page 50 and 51: COMMUNICATION INTERFACES> SERIAL CO
- Page 52 and 53: COMMUNICATION INTERFACES> SERIAL CO
- Page 54 and 55: COMMUNICATION INTERFACES> SERIAL CO
- Page 56 and 57: COMMUNICATION INTERFACES > Fiber Op
- Page 58 and 59: COMMUNICATION INTERFACES > Wireless
- Page 60 and 61: HMI- Displays > OLED DISPLAY WITH M
- Page 62 and 63: HMI- Displays > OLED DISPLAY WITH M
- Page 65 and 66: RTU, REMOTE TERMINAL UNITS 6 RTU, R
- Page 67 and 68: INTEGRATED SOLUTION ALL-IN-ONE REMO
- Page 69 and 70: RTU, REMOTE TERMINAL UNITS > M-RTU-
- Page 71 and 72: READY-TO-USE A DIGITAL CONTACTS REM
- Page 73: APPLICATIONS AUTOMATICALLY OPENING
- Page 76 and 77: Z-LINE > MULTI-STANDARD SIGNAL CONV
- Page 78 and 79: CONVERTERS & INTERFACES > MULTI-STA
- Page 80 and 81: CONVERTERS & INTERFACES > MULTI-STA
- Page 82 and 83: CONVERTERS & INTERFACES > MULTI-STA
- Page 84 and 85: CONVERTERS & INTERFACES > MULTI-STA
- Page 86 and 87: CONVERTERS & INTERFACES > MULTI-STA
- Page 88 and 89: CONVERTERS & INTERFACES > MULTI-STA
- Page 90 and 91: CONVERTERS & INTERFACES > MULTI-STA
COMMUNICATION INTERFACES> ETHERNET CONVERTERS<br />
Z-GW-MB<br />
<br />
12..40 Vdc / 19..28 Vac<br />
Power<br />
Supply<br />
ModBUS TCP-IP<br />
Z-GW-MB is a transparent ModBUS TCP/IP bridge for any ModBUS<br />
RTU serial device. It disposes of N.1 serial port, either RS485 and<br />
RS232, master or slave.<br />
On Ethernet side is available a 10 Base-t port. The communication<br />
through Ethernet is protected by a galvanic isolation at 1500 V<br />
MODBUS<br />
TCP -IP<br />
TECHNICAL SPECIFICATIONS<br />
General Data<br />
Power supply 12..28 Vac / 12..40 Vdc / 50-60 Hz<br />
Power consumption 1,2 W<br />
Isolation<br />
500 Vac<br />
Power transducers -<br />
Status Indicators Power supply, Ethernet link, Ethernet connection<br />
Protection Degree IP20<br />
Operating<br />
Temperature<br />
-20..+70 °C<br />
Dimension (W x H x D) 17.5 x 100 x 112 mm<br />
Mounting<br />
35 mm DIN rail guide<br />
Communication, Memory Process<br />
Master mode for the RS485 or RS232 communication port with<br />
Communication ports ModbusRTU protocol<br />
Maximum baud rate for ModbusRTU set to 115200 bps<br />
Ethernet to RS232 or RS485 for remote control of the ModbusRTU<br />
Ethernet<br />
device.<br />
communication<br />
10-BaseT Ethernet port (10 Mbit / S)<br />
Connection on RS485<br />
Removable screw terminal ( M4, M5, M6) or IDC10 (rear connector)<br />
port<br />
Connection on RS232<br />
DB9-F in the side of the module<br />
port<br />
Memory<br />
RJ45 front<br />
Standard<br />
Approvals<br />
CE<br />
Norms EN 61000-6-4/2002, EN 61000-6-2/2002, EN 61010, EN 60742<br />
APPLICATION NOTE<br />
ORDER CODES<br />
Z-GW-MB Z-GW-MB<br />
Code Description<br />
Z-GW-MB Modbus RTU / Modbus TCP-IP bridge (single serial port), 12..40 Vdc / 12..28 Vac<br />
ACCESSORIES & SOFTWARE<br />
Z-PC-DIN<br />
Z-SUPPLY<br />
Backplane for power & bus communication<br />
Switching power supply<br />
pg. 36 pg. 36<br />
SIMILAR <strong>PRODUCT</strong>S<br />
Z-BRIDGE Z-LWS Z107E<br />
Modbus RTU / Modbus TCP-IP<br />
Ethernet - RS232/RS485<br />
Micro PLC<br />
bridge (Four serial port)<br />
Adapter<br />
pg. 42 pg. 40 pg. 44<br />