PRODUCT CATALOG - Merkantile
PRODUCT CATALOG - Merkantile PRODUCT CATALOG - Merkantile
POWER DEVICES HANDHELD METER CALIBRATOR AC SIGNAL CONVERTERS OVERVOLTAGE PROTECTIONS ISOLATION TEST / FAULT DETECTION POWER CONSUMPTION MONITORING MACHINE SAFETY TEST BENCH POWER QUALITY CALIBRATION & DIAGNOSTIC 130
POWER DEVICES S203T Up to 600 Vdc Up to 100 mA (by CT) Input 10..40 Vdc, 19..28 Vac Power supply Output Communication Modbus mA, V S203T is a complete three-phase network analyser suited for use with up to 600 Vac voltage range and up to 100mA current range (specific CTs must be used). The instrument provides all the following electrical measurable variable: Vrms, Irms, Watt, Var, Va, Frequency, Cosφ. Measurements are availables through Modbus serial communication or through analogue retransmission (ma or V). A 3-way galvanic isolation among Power supply // input // RS485 circuits assures the integrity of your datas. TECHNICAL SPECIFICATIONS General Data Power supply 10..40 Vdc; 19..28 Vac (50-60 Hz) Power Consumption 2,5 W Isolation 3.750 Vac (from/to power) 1500 Vac (other circuits) Status Indicator Power supply, error, RS485 communication Accuracy class 0,2% Protection Degree IP20 Operating Temperature -10..+65 °C Dimension (W x H x D) 105 x 89 x 60 mm Weight About 160 g Enclosure Plastic Material UL V0 Mounting 35 mm DIN rail guide Communication Interface Speed Protocol Distance Connectivity Data Memory I/O Channel Numbers Input Type Output Type Programming DIP switches Software Standard 2 wire RS485 RS232, front jack, speed 2400 Baud, data bits 8, Parity: NO, Stop bits:1 Reading every 25 ms ModBUS RTU slave Up to 1.200 m Max 32 nodes EEPROM configuration parameters, retention time 10 years 1 input, 1 output Voltage: max 600 Vac, 50-60 Hz Current: 100mA from CT (S203T) -Single phase -Aron (three phase with N.2 CT) -Four wires (three-phase with N.3 CT)/ current) Rs485 Modbus RTU slave: 1200…115200 baud rate Analogue output: corresponding at Vrms, Irms, Watt, cosφ Address setting Baud rate setting - Selection of inserction type - Selection of 3 phase o 1 phase - Output All parameters Approval CE Norms EN 61000-6-4/2002, EN 61000-6-2/2002, EN 61010, EN 60742 APPLICATION NOTE CT (100 A / 5A) ORDER CODES Code S203T SENECA S203TA Description AC triple phase network analyzer, 100 mA input ACCESSORIES & SOFTWARE 220V TA15 TA25 TA100 EASY SETUP Current transformer (CT) – 15 A / 100 mA Current transformer (CT) – 25 A / 100 mA Current transformer (CT) – 100 A / 100 mA Plug&Play configuration software - - - pg. 98 SIMILAR PRODUCTS S203TA Z203 AC triple-phase network analyzer, 5 Arms input Single phase network analyzer pg. 132 pg. 89 131
- Page 80 and 81: CONVERTERS & INTERFACES > MULTI-STA
- Page 82 and 83: CONVERTERS & INTERFACES > MULTI-STA
- Page 84 and 85: CONVERTERS & INTERFACES > MULTI-STA
- Page 86 and 87: CONVERTERS & INTERFACES > MULTI-STA
- Page 88 and 89: CONVERTERS & INTERFACES > MULTI-STA
- Page 90 and 91: CONVERTERS & INTERFACES > MULTI-STA
- Page 92 and 93: CONVERTERS & INTERFACES > MULTI-STA
- Page 94 and 95: CONVERTERS & INTERFACES > MULTI-STA
- Page 96 and 97: CONVERTERS & INTERFACES > MULTI-STA
- Page 98 and 99: CONVERTERS & INTERFACES > MULTI-STA
- Page 100 and 101: K-LINE > COMPACT SIGNAL CONVERTERS
- Page 102 and 103: CONVERTERS & INTERFACES > MULTI-STA
- Page 104 and 105: CONVERTERS & INTERFACES > MULTI-STA
- Page 106 and 107: CONVERTERS & INTERFACES > MULTI-STA
- Page 108 and 109: CONVERTERS & INTERFACES > MULTI-STA
- Page 110 and 111: CONVERTERS & INTERFACES > MULTI-STA
- Page 112 and 113: CONVERTERS & INTERFACES > COMPACT S
- Page 114 and 115: CONVERTERS & INTERFACES > COMPACT S
- Page 116 and 117: LOOP POWERED DEVICES > Temperature
- Page 118 and 119: LOOP POWERED DEVICES > Current Tran
- Page 120 and 121: 120
- Page 122 and 123: DISPLAYS AND PANEL MOUNTING UNITS H
- Page 124 and 125: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 126 and 127: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 128 and 129: 128
- Page 132 and 133: POWER DEVICES S203TA Up to 6
- Page 134 and 135: POWER DEVICES > Z-LINE AC POWER CON
- Page 136 and 137: POWER DEVICES > Z-LINE AC POWER CON
- Page 138 and 139: PHOTOVOLTAIC COMPONENTS SENECA MODU
- Page 140 and 141: S PWR ERR COM RX TX 4 5 6 PHOTOVOLT
- Page 142 and 143: PHOTOVOLTAIC COMPONENTS COMPONENTS
- Page 144: www.seneca.it CONTACT AND INFORMATI
POWER DEVICES<br />
<br />
<br />
HANDHELD METER CALIBRATOR<br />
AC SIGNAL CONVERTERS<br />
OVERVOLTAGE PROTECTIONS<br />
ISOLATION TEST<br />
/ FAULT DETECTION<br />
POWER CONSUMPTION<br />
MONITORING<br />
MACHINE<br />
SAFETY<br />
TEST<br />
BENCH<br />
POWER<br />
QUALITY<br />
CALIBRATION<br />
& DIAGNOSTIC<br />
130