PRODUCT CATALOG - Merkantile
PRODUCT CATALOG - Merkantile PRODUCT CATALOG - Merkantile
DISPLAYS AND PANEL MOUNTING UNITS Highest accuracy, lowest price 4 DIGIT LOOP POWERED DISPLAYS ANALOG INPUT: 4..20 mA POWER SUPPLY: By the 4..20 mA input loop S315 4 DIGIT DISPLAYS AND I/V ANALOG INPUT ANALOG INPUT: mA, V POWER SUPPLY: 10-40 Vdc, 19-28 Vac S311AK IP66 IP66 4, 6, 8, 11 DIGIT UNIVERSAL ANALOG INPUT DISPLAYS S311A S311D 4, 6, 8, 11 DIGIT FREQUENCY / DIGITAL INPUT DISPLAYS ANALOG INPUT: mA, V, potentiometer, Pt100, POWER SUPPLY: 10-40 Vdc, 19-28 Vac; 80-265 Vac DIGITAL INPUT: Reed, npn, pnp, namur, photoelectric, POWER SUPPLY: 10-40 Vdc, 19-28 Vac; 80-265 Vac MODULAR DISPLAY UNIVERSAL INPUT RE-TRANSMITTED OUTPUT WIDE RANGE SUPPLY HIGH ACCURACY RELAY ALARMS INTEGRATION & TOTALIZATION 0,05% SPDT x y ADVANCED FUNCTIONS 122
DISPLAYS AND PANEL MOUNTING UNITS S311A-4 S311A-6 S311A-8 S311A-11 TECHNICAL SPECIFICATIONS General Data Power supply 80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc / 19-28 Vac (L version) 19-28 Vac (L version) 19-28 Vac (L version) 19-28 Vac (L version) Power transducers Max 18 V, 25 mA Max 18 V, 25 mA Max 18 V, 25 mA Max 18 V, 25 mA Power consumption 3 W 3 W 3 W 3 W Isolation 1.500 Vac 1.500 Vac 1.500 Vac 1.500 Vac Communication interface ModBUS RTU slave (optional board) ModBUS RTU slave (optional board) ModBUS RTU slave (optional board) ModBUS RTU slave (optional board) Memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory Visualization And Measure Display LED, 4 digit LED, 6 digit LED, 8 digit LED, 11 (4+7) digit Status indicators 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips) Front Buttons 3 navigation keys 3 navigation keys 3 navigation keys 3 navigation keys Display errors Over range, fault sensor Over range, fault sensor Over range, fault sensor Over range, fault sensor Accuracy 0,1% 0,1% 0,1% 0,1% Stability 0,01%/K 0,01%/K 0,01%/K 0,01%/K Linearity error 0,2°C (Pt100) 0,5° (TC J,K,E,N,T) 1°C (TC R,S) 2°C (TC B) 0,05% (0-10 V, 0-20 mA) 0,2°C (Pt100) 0,5° (TC J,K,E,N,T) 1°C (TC R,S) 2°C (TC B) 0,05% (0-10 V, 0-20 mA) 0,2°C (Pt100) 0,5° (TC J,K,E,N,T) 1°C (TC R,S) 2°C (TC B) 0,05% (0-10 V, 0-20 mA) Cold joint ±1,5°C ±1,5°C ±1,5°C ±1,5°C Input Data Nr 1 1 1 1 Type 4 digit universal analog input indicator - totalizer and analog output Voltage: 0-10 V Active / passive current: 0-20 / 4..20 mA Potentiometer: 1..100 kΩ Pt100 2,3,4 wire (IEC 751 / EN 60751 – ITS90) Thermocouple J,K,R,S,T,B,E,N 6 digit universal analog input indicator - totalizer and analog output Voltage: 0-10 V Active / passive current: 0-20 / 4..20 mA Potentiometer: 1..100 kΩ Pt100 2,3,4 wire (IEC 751 / EN 60751 – ITS90) Thermocouple J,K,R,S,T,B,E,N 8 digit universal analog input indicator - totalizer and analog output Voltage: 0-10 V Active / passive current: 0-20 / 4..20 mA Potentiometer: 1..100 kΩ Pt100 2,3,4 wire (IEC 751 / EN 60751 – ITS90) Thermocouple J,K,R,S,T,B,E,N 0,2°C (Pt100) 0,5° (TC J,K,E,N,T) 1°C (TC R,S) 2°C (TC B) 0,05% (0-10 V, 0-20 mA) Voltage: 0-10 V Active / passive current: 0-20 / 4..20 mA Potentiometer: 1..100 kΩ Pt100 2,3,4 wire (IEC 751 / EN 60751 – ITS90) Thermocouple J,K,R,S,T,B,E,N Resolution 14 bit 14 bit 14 bit 14 bit Sampling time 20 ms 20 ms 20 ms 20 ms Reset (totalizer) Yes: by digital input and front keys Yes: by digital input and front keys Yes: by digital input and front keys Yes: by digital input and front keys Output Data Nr 1 1 1 1 Type 0-10 V (min 1K) 0-10 V (min 1K) 0-10 V (min 1K) 0-20 / 4-20 mA (max 500 ohm) 0-20 / 4-20 mA (max 500 ohm) 0-20 / 4-20 mA (max 500 ohm) A/D Resolution 10.000 points 10.000 points 10.000 points 10.000 points Nr 2 SPDT 220 Vac (5A resistive, Nr 2 SPDT 220 Vac (5A resistive, Nr 2 SPDT 220 Vac (5A resistive, Optional board 2 A inductive) relay alarms + Nr 1 2 A inductive) relay alarms + Nr 1 2 A inductive) relay alarms + Nr 1 RS485ModBUS RTU slave port + nr 1 RS485ModBUS RTU slave port + nr 1 RS485ModBUS RTU slave port + nr 1 reset digital input reset digital input reset digital input 0-10 V (min 1K) 0-20 / 4-20 mA (max 500 ohm) Nr 2 SPDT 220 Vac (5A resistive, 2 A inductive) relay alarms + Nr 1 RS485ModBUS RTU slave port + nr 1 reset digital input Themomechanics Data Operating temperature -10..+60 °C -10..+60 °C -10..+60 °C -10..+60 °C Enclosure PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700 Protection degree IP65 (frontal) IP65 (frontal) IP65 (frontal) IP65 (frontal) Terminal blocks Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm Dimension (w x h x d) 96x48x98 mm 96x48x98 mm 96x48x98 mm 96x48x98 mm Panel cut -out 91x45 mm 91x45 mm 91x45 mm 91x45 mm Weight 200 g 200 g 200 g 200 g Settings, Norms Display parameters, alarms, signals, Display parameters, alarms, signals, Display parameters, alarms, signals, Software / settings timeout, reset, trips timeout, reset, trips timeout, reset, trips Calibration Yes, factory-made Yes, factory-made Yes, factory-made Yes, factory-made EN 61000-6-4/2002, EN 61000-6- EN 61000-6-4/2002, EN 61000-6- EN 61000-6-4/2002, EN 61000-6- Norms 2/2005, EN 61010-1/2001 2/2005, EN 61010-1/2001 2/2005, EN 61010-1/2001 S311A is an universal display with analog input (mA, V, PT100, TCs, Ohm) that allows to view the istantaneous value (engineering units), retransmit it through an isolated analog output and, by the optional board, have N.2 relay alarms and Modbus interface. Furthermore the unit allows to integrate the input and totalize it into the internal memory. It is available with 4,6 or 8 digits and an 7+4 digits (double line). ORDER CODES 11 digit universal analog input indicator - totalizer and analog output Display parameters, alarms, signals, timeout, reset, trips EN 61000-6-4/2002, EN 61000-6- 2/2005, EN 61010-1/2001 Code Description Model S331A Universal analog input indicator - totalizer and analog output Display -4 / -6 / -8 / -11 4 / 6 / 8 / 4+7 digit Power Supply -H / -L 80-265 Vac / 10-40 Vdc; 19-28 Vac Optional board: nr 2 SPDT relay alarms, ModBUS RTU interface, -O Options reset input /T Calibration service Software EASYS311A Plug&play software configurator via serial converter to RS485 (i.e. S107USB) 123
- Page 71 and 72: READY-TO-USE A DIGITAL CONTACTS REM
- Page 73: APPLICATIONS AUTOMATICALLY OPENING
- Page 76 and 77: Z-LINE > MULTI-STANDARD SIGNAL CONV
- Page 78 and 79: CONVERTERS & INTERFACES > MULTI-STA
- Page 80 and 81: CONVERTERS & INTERFACES > MULTI-STA
- Page 82 and 83: CONVERTERS & INTERFACES > MULTI-STA
- Page 84 and 85: CONVERTERS & INTERFACES > MULTI-STA
- Page 86 and 87: CONVERTERS & INTERFACES > MULTI-STA
- Page 88 and 89: CONVERTERS & INTERFACES > MULTI-STA
- Page 90 and 91: CONVERTERS & INTERFACES > MULTI-STA
- Page 92 and 93: CONVERTERS & INTERFACES > MULTI-STA
- Page 94 and 95: CONVERTERS & INTERFACES > MULTI-STA
- Page 96 and 97: CONVERTERS & INTERFACES > MULTI-STA
- Page 98 and 99: CONVERTERS & INTERFACES > MULTI-STA
- Page 100 and 101: K-LINE > COMPACT SIGNAL CONVERTERS
- Page 102 and 103: CONVERTERS & INTERFACES > MULTI-STA
- Page 104 and 105: CONVERTERS & INTERFACES > MULTI-STA
- Page 106 and 107: CONVERTERS & INTERFACES > MULTI-STA
- Page 108 and 109: CONVERTERS & INTERFACES > MULTI-STA
- Page 110 and 111: CONVERTERS & INTERFACES > MULTI-STA
- Page 112 and 113: CONVERTERS & INTERFACES > COMPACT S
- Page 114 and 115: CONVERTERS & INTERFACES > COMPACT S
- Page 116 and 117: LOOP POWERED DEVICES > Temperature
- Page 118 and 119: LOOP POWERED DEVICES > Current Tran
- Page 120 and 121: 120
- Page 124 and 125: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 126 and 127: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 128 and 129: 128
- Page 130 and 131: POWER DEVICES HANDHELD METER
- Page 132 and 133: POWER DEVICES S203TA Up to 6
- Page 134 and 135: POWER DEVICES > Z-LINE AC POWER CON
- Page 136 and 137: POWER DEVICES > Z-LINE AC POWER CON
- Page 138 and 139: PHOTOVOLTAIC COMPONENTS SENECA MODU
- Page 140 and 141: S PWR ERR COM RX TX 4 5 6 PHOTOVOLT
- Page 142 and 143: PHOTOVOLTAIC COMPONENTS COMPONENTS
- Page 144: www.seneca.it CONTACT AND INFORMATI
DISPLAYS AND PANEL MOUNTING UNITS<br />
S311A-4 S311A-6 S311A-8 S311A-11<br />
TECHNICAL SPECIFICATIONS<br />
General Data<br />
Power supply<br />
80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc / 80-265 Vac (H version) 10-40 Vdc /<br />
19-28 Vac (L version)<br />
19-28 Vac (L version)<br />
19-28 Vac (L version)<br />
19-28 Vac (L version)<br />
Power transducers Max 18 V, 25 mA Max 18 V, 25 mA Max 18 V, 25 mA Max 18 V, 25 mA<br />
Power consumption 3 W 3 W 3 W 3 W<br />
Isolation 1.500 Vac 1.500 Vac 1.500 Vac 1.500 Vac<br />
Communication interface ModBUS RTU slave (optional board) ModBUS RTU slave (optional board) ModBUS RTU slave (optional board) ModBUS RTU slave (optional board)<br />
Memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory EEPROM 10 years, storage memory<br />
Visualization And Measure<br />
Display LED, 4 digit LED, 6 digit LED, 8 digit LED, 11 (4+7) digit<br />
Status indicators 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips) 2 alarm leds (enabled threshold trips)<br />
Front Buttons 3 navigation keys 3 navigation keys 3 navigation keys 3 navigation keys<br />
Display errors Over range, fault sensor Over range, fault sensor Over range, fault sensor Over range, fault sensor<br />
Accuracy 0,1% 0,1% 0,1% 0,1%<br />
Stability 0,01%/K 0,01%/K 0,01%/K 0,01%/K<br />
Linearity error<br />
0,2°C (Pt100)<br />
0,5° (TC J,K,E,N,T)<br />
1°C (TC R,S)<br />
2°C (TC B)<br />
0,05% (0-10 V, 0-20 mA)<br />
0,2°C (Pt100)<br />
0,5° (TC J,K,E,N,T)<br />
1°C (TC R,S)<br />
2°C (TC B)<br />
0,05% (0-10 V, 0-20 mA)<br />
0,2°C (Pt100)<br />
0,5° (TC J,K,E,N,T)<br />
1°C (TC R,S)<br />
2°C (TC B)<br />
0,05% (0-10 V, 0-20 mA)<br />
Cold joint ±1,5°C ±1,5°C ±1,5°C ±1,5°C<br />
Input Data<br />
Nr 1 1 1 1<br />
Type<br />
4 digit universal analog input<br />
indicator - totalizer and analog output<br />
Voltage: 0-10 V<br />
Active / passive current: 0-20 / 4..20 mA<br />
Potentiometer: 1..100 kΩ<br />
Pt100 2,3,4 wire (IEC 751 / EN<br />
60751 – ITS90)<br />
Thermocouple J,K,R,S,T,B,E,N<br />
6 digit universal analog input<br />
indicator - totalizer and analog output<br />
Voltage: 0-10 V<br />
Active / passive current: 0-20 / 4..20 mA<br />
Potentiometer: 1..100 kΩ<br />
Pt100 2,3,4 wire (IEC 751 / EN<br />
60751 – ITS90)<br />
Thermocouple J,K,R,S,T,B,E,N<br />
8 digit universal analog input<br />
indicator - totalizer and analog output<br />
Voltage: 0-10 V<br />
Active / passive current: 0-20 / 4..20 mA<br />
Potentiometer: 1..100 kΩ<br />
Pt100 2,3,4 wire (IEC 751 / EN<br />
60751 – ITS90)<br />
Thermocouple J,K,R,S,T,B,E,N<br />
0,2°C (Pt100)<br />
0,5° (TC J,K,E,N,T)<br />
1°C (TC R,S)<br />
2°C (TC B)<br />
0,05% (0-10 V, 0-20 mA)<br />
Voltage: 0-10 V<br />
Active / passive current: 0-20 / 4..20 mA<br />
Potentiometer: 1..100 kΩ<br />
Pt100 2,3,4 wire (IEC 751 / EN<br />
60751 – ITS90)<br />
Thermocouple J,K,R,S,T,B,E,N<br />
Resolution 14 bit 14 bit 14 bit 14 bit<br />
Sampling time 20 ms 20 ms 20 ms 20 ms<br />
Reset (totalizer) Yes: by digital input and front keys Yes: by digital input and front keys Yes: by digital input and front keys Yes: by digital input and front keys<br />
Output Data<br />
Nr 1 1 1 1<br />
Type<br />
0-10 V (min 1K)<br />
0-10 V (min 1K)<br />
0-10 V (min 1K)<br />
0-20 / 4-20 mA (max 500 ohm) 0-20 / 4-20 mA (max 500 ohm) 0-20 / 4-20 mA (max 500 ohm)<br />
A/D Resolution 10.000 points 10.000 points 10.000 points 10.000 points<br />
Nr 2 SPDT 220 Vac (5A resistive, Nr 2 SPDT 220 Vac (5A resistive, Nr 2 SPDT 220 Vac (5A resistive,<br />
Optional board<br />
2 A inductive) relay alarms + Nr 1 2 A inductive) relay alarms + Nr 1 2 A inductive) relay alarms + Nr 1<br />
RS485ModBUS RTU slave port + nr 1 RS485ModBUS RTU slave port + nr 1 RS485ModBUS RTU slave port + nr 1<br />
reset digital input<br />
reset digital input<br />
reset digital input<br />
0-10 V (min 1K)<br />
0-20 / 4-20 mA (max 500 ohm)<br />
Nr 2 SPDT 220 Vac (5A resistive,<br />
2 A inductive) relay alarms + Nr 1<br />
RS485ModBUS RTU slave port + nr 1<br />
reset digital input<br />
Themomechanics Data<br />
Operating temperature -10..+60 °C -10..+60 °C -10..+60 °C -10..+60 °C<br />
Enclosure PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700 PPO self-extinguish DIN 43700<br />
Protection degree IP65 (frontal) IP65 (frontal) IP65 (frontal) IP65 (frontal)<br />
Terminal blocks Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm Removable, step 3,5 – 5,08 mm<br />
Dimension (w x h x d) 96x48x98 mm 96x48x98 mm 96x48x98 mm 96x48x98 mm<br />
Panel cut -out 91x45 mm 91x45 mm 91x45 mm 91x45 mm<br />
Weight 200 g 200 g 200 g 200 g<br />
Settings, Norms<br />
Display parameters, alarms, signals, Display parameters, alarms, signals, Display parameters, alarms, signals,<br />
Software / settings<br />
timeout, reset, trips<br />
timeout, reset, trips<br />
timeout, reset, trips<br />
Calibration Yes, factory-made Yes, factory-made Yes, factory-made Yes, factory-made<br />
EN 61000-6-4/2002, EN 61000-6- EN 61000-6-4/2002, EN 61000-6- EN 61000-6-4/2002, EN 61000-6-<br />
Norms<br />
2/2005, EN 61010-1/2001 2/2005, EN 61010-1/2001 2/2005, EN 61010-1/2001<br />
S311A is an universal display with analog input (mA, V, PT100, TCs, Ohm)<br />
that allows to view the istantaneous value (engineering units), retransmit<br />
it through an isolated analog output and, by the optional board, have<br />
N.2 relay alarms and Modbus interface. Furthermore the unit allows to<br />
integrate the input and totalize it into the internal memory. It is available<br />
with 4,6 or 8 digits and an 7+4 digits (double line).<br />
ORDER CODES<br />
11 digit universal analog input<br />
indicator - totalizer and analog output<br />
Display parameters, alarms, signals,<br />
timeout, reset, trips<br />
EN 61000-6-4/2002, EN 61000-6-<br />
2/2005, EN 61010-1/2001<br />
Code<br />
Description<br />
Model S331A Universal analog input indicator - totalizer and analog output<br />
Display -4 / -6 / -8 / -11 4 / 6 / 8 / 4+7 digit<br />
Power Supply -H / -L 80-265 Vac / 10-40 Vdc; 19-28 Vac<br />
Optional board: nr 2 SPDT relay alarms, ModBUS RTU interface,<br />
-O<br />
Options<br />
reset input<br />
/T Calibration service<br />
Software<br />
EASYS311A Plug&play software configurator via serial converter<br />
to RS485 (i.e. S107USB)<br />
123