PRODUCT CATALOG - Merkantile
PRODUCT CATALOG - Merkantile PRODUCT CATALOG - Merkantile
CONVERTERS & INTERFACES > MULTI-STANDARD SIGNAL CONVERTERS ISOLATORS > Analog Converters DC CURRENT / VOLTAGE TO DC CURRENT/VOLTAGE ISOLATOR/CONVERTER V Power Supply Input 19,2...30 Vdc Output V K109S is a device that accepts mA/V signals able to convert it into mA/V standard signals. The device can power also all 2-wire sensors and all parameters are configurable through dip-switches. The power supply connection is available on the terminals or a special connector (K-BUS) allows a distribution of the power supply to the modules via bus connector. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas. TECHNICAL SPECIFICATIONS General Data Power supply 19,2…30 Vdc Power consumption 500 mW Isolation 1.500 Vac (3 way) Transducer Power Supply Yes Accuracy 0,1% Response time 40 ms Status Indicators Power supply, error Setting Dip Switches Mounting 35 mm DIN rail guide Protection Degree IP20 Operating Temperature -20..+65 °C Dimension (W x H x D) 6,2 x 93 x 102,5 mm Input Channel Numbers 1 Range: 0..10 / 10..0 / 0..5 / 1..5 V Voltage Impedance: 110 kΩ Range: 4..20 / 20..4 / 0..20 / 20..0 mA Current (active or passive input) Impedance: 35 Ω Output Channel Numbers 1 Voltage Range: 0..10 / 10..0 / 0..5 / 1..5 V Min load resistance: 2 kΩ Range: 4..20 / 20..4 / 0..20 / 20..0 mA Current Max load resistance: 500 Ω Protection: 25 mA Standard Approval CE Norms EN 50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN 50140/141; EN 61010-1 APPLICATION NOTE ORDER CODES Code K109S SIMILAR PRODUCTS 19,2..30 Vdc Analog signal isolation, retransimission, Description DC current/voltage to DC current/voltage isolator/converter (with power for 2-wire sensors) ACCESSORIES & SOFTWARE ° Backplane for power connection Redundant power supply module pg. 114 pg. 114 Z109UI2 Z109S DC current / voltage to DC current/voltage isolator/ DC current / voltage to DC current/voltage isolator/ DC current isolator converter converter pg. 103 pg. 80 pg. 81 104
+ CONVERTERS & INTERFACES > MULTI-STANDARD SIGNAL CONVERTERS ISOLATORS > Analog Converters DC LOW VOLTAGE TO DC CURRENT/VOLTAGE ISOLATOR/CONVERTER mV Power Supply Input 19,2...30 Vdc Output V K109LV allows a conversion of the signals with mV (±25 mV.. ±2000 mV) standard into mA/V standard signals. It’s useful for DC current monitoring through shunts. The power supply connection is available on the terminals or a special connector (K-BUS) allows a distribution of the power supply to the modules via bus connector. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas. TECHNICAL SPECIFICATIONS General Data Power supply 19,2…30 Vdc Power consumption 500 mW Isolation 1.500 Vac (3 way) Transducer Power Supply - Accuracy 0,1% Response time 25 ms Status Indicators Power supply, error Setting Dip Switches Mounting 35 mm DIN rail guide Protection Degree IP20 Operating Temperature -20..+65 °C Dimension (W x H x D) 6,2 x 93 x 102,5 mm Input Channel Numbers 1 Voltage (mV) Range: ±25, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300, 400, 500, 1000, 2000 mV (via Dip switches) Output Channel Numbers 1 Voltage Range: 0..10 / 10..0 / 0..5 / 1..5 V Min load resistance: 2 kΩ Range: 4..20 / 20..4 / 0..20 / 20..0 mA Current Max load resistance: 500 Ω Protection: 25 mA Standard Approval CE Norms EN 50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN 50140/141; EN 61010-1 APPLICATION NOTE String current measurement and Photovoltaic string Photovoltaic string ORDER CODES Code K109LV K109LV Shunt 60/200 mV Max 4-20 mA Max isolation 1,5 kV Max 4-20 mA T201DC (40A) Electrical cabinet Description DC Low Voltage to DC current/voltage isolator/converter ACCESSORIES & SOFTWARE Backplane for power connection Redundant power supply module pg. 114 pg. 114 PLC SIMILAR PRODUCTS Z109REG2 Z-4TC Universal converter to DC current/voltage isolator converter with alarm output Loop powered universal converter 4-CH thermocouple/mV input module / RS485 pg. 78 pg. 102 pg. 34 105
- Page 54 and 55: COMMUNICATION INTERFACES> SERIAL CO
- Page 56 and 57: COMMUNICATION INTERFACES > Fiber Op
- Page 58 and 59: COMMUNICATION INTERFACES > Wireless
- Page 60 and 61: HMI- Displays > OLED DISPLAY WITH M
- Page 62 and 63: HMI- Displays > OLED DISPLAY WITH M
- Page 65 and 66: RTU, REMOTE TERMINAL UNITS 6 RTU, R
- Page 67 and 68: INTEGRATED SOLUTION ALL-IN-ONE REMO
- Page 69 and 70: RTU, REMOTE TERMINAL UNITS > M-RTU-
- Page 71 and 72: READY-TO-USE A DIGITAL CONTACTS REM
- Page 73: APPLICATIONS AUTOMATICALLY OPENING
- Page 76 and 77: Z-LINE > MULTI-STANDARD SIGNAL CONV
- Page 78 and 79: CONVERTERS & INTERFACES > MULTI-STA
- Page 80 and 81: CONVERTERS & INTERFACES > MULTI-STA
- Page 82 and 83: CONVERTERS & INTERFACES > MULTI-STA
- Page 84 and 85: CONVERTERS & INTERFACES > MULTI-STA
- Page 86 and 87: CONVERTERS & INTERFACES > MULTI-STA
- Page 88 and 89: CONVERTERS & INTERFACES > MULTI-STA
- Page 90 and 91: CONVERTERS & INTERFACES > MULTI-STA
- Page 92 and 93: CONVERTERS & INTERFACES > MULTI-STA
- Page 94 and 95: CONVERTERS & INTERFACES > MULTI-STA
- Page 96 and 97: CONVERTERS & INTERFACES > MULTI-STA
- Page 98 and 99: CONVERTERS & INTERFACES > MULTI-STA
- Page 100 and 101: K-LINE > COMPACT SIGNAL CONVERTERS
- Page 102 and 103: CONVERTERS & INTERFACES > MULTI-STA
- Page 106 and 107: CONVERTERS & INTERFACES > MULTI-STA
- Page 108 and 109: CONVERTERS & INTERFACES > MULTI-STA
- Page 110 and 111: CONVERTERS & INTERFACES > MULTI-STA
- Page 112 and 113: CONVERTERS & INTERFACES > COMPACT S
- Page 114 and 115: CONVERTERS & INTERFACES > COMPACT S
- Page 116 and 117: LOOP POWERED DEVICES > Temperature
- Page 118 and 119: LOOP POWERED DEVICES > Current Tran
- Page 120 and 121: 120
- Page 122 and 123: DISPLAYS AND PANEL MOUNTING UNITS H
- Page 124 and 125: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 126 and 127: DISPLAYS AND PANEL MOUNTING UNITS S
- Page 128 and 129: 128
- Page 130 and 131: POWER DEVICES HANDHELD METER
- Page 132 and 133: POWER DEVICES S203TA Up to 6
- Page 134 and 135: POWER DEVICES > Z-LINE AC POWER CON
- Page 136 and 137: POWER DEVICES > Z-LINE AC POWER CON
- Page 138 and 139: PHOTOVOLTAIC COMPONENTS SENECA MODU
- Page 140 and 141: S PWR ERR COM RX TX 4 5 6 PHOTOVOLT
- Page 142 and 143: PHOTOVOLTAIC COMPONENTS COMPONENTS
- Page 144: www.seneca.it CONTACT AND INFORMATI
+<br />
CONVERTERS & INTERFACES > MULTI-STANDARD SIGNAL CONVERTERS ISOLATORS > Analog Converters<br />
<br />
DC LOW VOLTAGE TO DC CURRENT/VOLTAGE ISOLATOR/CONVERTER<br />
mV<br />
Power<br />
Supply<br />
Input<br />
19,2...30<br />
Vdc<br />
Output<br />
V<br />
K109LV allows a conversion of the signals with mV (±25 mV..<br />
±2000 mV) standard into mA/V standard signals. It’s useful for DC<br />
current monitoring through shunts. The power supply connection<br />
is available on the terminals or a special connector (K-BUS) allows<br />
a distribution of the power supply to the modules via bus connector.<br />
A 3-way galvanic isolation among Power supply // input // output<br />
circuits assures the integrity of your datas.<br />
TECHNICAL SPECIFICATIONS<br />
General Data<br />
Power supply 19,2…30 Vdc<br />
Power consumption 500 mW<br />
Isolation<br />
1.500 Vac (3 way)<br />
Transducer Power<br />
Supply<br />
-<br />
Accuracy 0,1%<br />
Response time 25 ms<br />
Status Indicators Power supply, error<br />
Setting<br />
Dip Switches<br />
Mounting<br />
35 mm DIN rail guide<br />
Protection Degree IP20<br />
Operating<br />
Temperature<br />
-20..+65 °C<br />
Dimension (W x H x D) 6,2 x 93 x 102,5 mm<br />
Input<br />
Channel Numbers 1<br />
Voltage (mV)<br />
Range: ±25, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300, 400,<br />
500, 1000, 2000 mV (via Dip switches)<br />
Output<br />
Channel Numbers 1<br />
Voltage<br />
Range: 0..10 / 10..0 / 0..5 / 1..5 V<br />
Min load resistance: 2 kΩ<br />
Range: 4..20 / 20..4 / 0..20 / 20..0 mA<br />
Current<br />
Max load resistance: 500 Ω<br />
Protection: 25 mA<br />
Standard<br />
Approval<br />
CE<br />
Norms<br />
EN 50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN<br />
50140/141; EN 61010-1<br />
APPLICATION NOTE<br />
String current measurement and<br />
<br />
Photovoltaic string<br />
Photovoltaic string<br />
ORDER CODES<br />
Code<br />
K109LV<br />
K109LV<br />
Shunt<br />
60/200 mV<br />
Max 4-20 mA<br />
Max isolation 1,5 kV<br />
Max 4-20 mA<br />
T201DC (40A)<br />
Electrical cabinet<br />
Description<br />
DC Low Voltage to DC current/voltage isolator/converter<br />
ACCESSORIES & SOFTWARE<br />
<br />
<br />
Backplane for power connection<br />
Redundant power supply module<br />
pg. 114 pg. 114<br />
PLC<br />
SIMILAR <strong>PRODUCT</strong>S<br />
Z109REG2 Z-4TC<br />
Universal converter to DC<br />
current/voltage isolator<br />
converter with alarm output<br />
Loop powered universal<br />
converter<br />
4-CH thermocouple/mV input<br />
module / RS485<br />
pg. 78 pg. 102 pg. 34<br />
105