2VOICE Residential compound 2Voice is the only system capable of satisfying the needs of building compounds with up to 4096 users and 27,200 metres of total wiring with ONLY two wires in each segment. Up to four common entrances may be present in the compound and each building may have two secondary switching entrances in turn. A concierge switchboard can be installed to further expand the advantages of the system. All maintaining cyclic control on external cameras and supplementary function activation (garden lane lights, watering sprinkler systems, staircase lights, etc.). 2 UP TO 32 DISTRIBUTORS FOR 128 USERS UP TO 32 DISTRIBUTORS FOR 128 USERS 2 2 2 2 2 2 2 2 2 Power supply unit 1083/20 4-user distributor 1083/55 4-user distributor 1083/55 2 2 Column interface 1083/50 Power supply unit 1083/20 Column interface 1083/50 2 2 2 2 2 2 2 UP TO 32 BUILDINGS 2 Apartment station Power supply unit 1083/20 interface/HUB 1083/75 Power supply unit 1083/20 2 2 UP TO 4 COMMON MAIN ENTRANCES 2 NOTE: See the wire compatibility table on page 35 for extensions, distances and number of users. 34 •

INTEGRATED SYSTEMS WIRE COMPATIBILITY TABLE SYSTEMS WIRES MAX. USERS MONITORS A M. BETWEEN ENTRY PANEL AND POWER SUPPLY UNIT B M. BETWEEN POWER SUPPLY UNIT AND MONITOR Extension M* 2Voice wire 128 Colour B/W 200 200 200 200 800 800 White/red double diameter 0.6 m without sheath 64 Colour B/W 100 100 150 125 600 600 CAT5 UTP (1 twisted pair) 64 Colour B/W 100 100 125 75 800 800 HVV05-F rubber covered 1.5 mm 2 128 Colour B/W 50 50 125 125 300 300 Urmet wire 7057/235 blue/red 64 Colour B/W 50 50 125 125 300 300 Single wire cross-section area 1 mm 2 ** 32 Colour B/W 50 50 75 75 150 150 Contact the sales and/or assistance network for further indications on using existing wires. When using multipolar cables, NEVER short-circuit several conductors to increase the wire cross-section area. * Extension is the sum of all cabled segments both in apartment and in riser column to the entry panel. ** Single cables must be installed in tube with maximum diameter of 32 mm. Distance A Distance B • 35

INTEGRATED SYSTEMS<br />

WIRE COMPATIBILITY TABLE<br />

SYSTEMS<br />

WIRES<br />

MAX.<br />

USERS<br />

MONITORS<br />

A<br />

M. BETWEEN ENTRY<br />

PANEL AND POWER<br />

SUPPLY UNIT<br />

B<br />

M. BETWEEN<br />

POWER SUPPLY UNIT<br />

AND MONITOR<br />

Extension<br />

M*<br />

2Voice wire<br />

128<br />

Colour<br />

B/W<br />

200<br />

200<br />

200<br />

200<br />

800<br />

800<br />

White/red<br />

double diameter<br />

0.6 m without<br />

sheath<br />

64<br />

Colour<br />

B/W<br />

100<br />

100<br />

150<br />

125<br />

600<br />

600<br />

CAT5 UTP<br />

(1 twisted pair)<br />

64<br />

Colour<br />

B/W<br />

100<br />

100<br />

125<br />

75<br />

800<br />

800<br />

HVV05-F<br />

rubber covered<br />

1.5 mm 2<br />

128<br />

Colour<br />

B/W<br />

50<br />

50<br />

125<br />

125<br />

300<br />

300<br />

<strong>Urmet</strong> wire<br />

7057/235<br />

blue/red<br />

64<br />

Colour<br />

B/W<br />

50<br />

50<br />

125<br />

125<br />

300<br />

300<br />

Single wire<br />

cross-section<br />

area 1 mm 2 **<br />

32<br />

Colour<br />

B/W<br />

50<br />

50<br />

75<br />

75<br />

150<br />

150<br />

Contact the sales and/or assistance network for further indications on using existing wires.<br />

When using multipolar cables, NEVER short-circuit several conductors to increase the wire cross-section area.<br />

* Extension is the sum of all cabled segments both in apartment and in riser column to the entry panel.<br />

** Single cables must be installed in tube with maximum diameter of 32 mm.<br />

Distance A<br />

Distance B<br />

• 35