RS232 Communications Protocol & Command Set (continued)<br />

Request Input Voltage Level<br />

Transmit the input AC voltage status<br />

Identify Equipment<br />

Transmit the model number, firmware number and revision.<br />

Send to <strong>UPS</strong>:<br />

INPUTVOLTS<br />

Send to <strong>UPS</strong>:<br />

ID<br />

Response from <strong>UPS</strong>:<br />

XXXVACIN<br />

Response from <strong>UPS</strong>:<br />

PANAMAX<br />

Request Output Voltage Status<br />

Transmit the output voltage state<br />

XXX is the input AC voltage represented<br />

in ASCII.<br />

<strong>M1500</strong>-<strong>UPS</strong><br />

FWPARTNUMBER<br />

REVREVISION<br />

Send to <strong>UPS</strong>:<br />

Response from <strong>UPS</strong>:<br />

OUTPUTSTAT<br />

XXXVACOUT<br />

XXX is the output voltage represented<br />

in ASCII.<br />

List all Commands and Queries<br />

Send to <strong>UPS</strong>:<br />

HELP<br />

Response from <strong>UPS</strong>: MAIN_ON<br />

If the <strong>UPS</strong> is not in AVR or BATTERY mode:<br />

Response from <strong>UPS</strong>: NORMAL<br />

If the <strong>UPS</strong> is in AVR mode and boosting voltage by 13%<br />

Response from <strong>UPS</strong>: AVRBOOST1<br />

If the <strong>UPS</strong> is in AVR mode and boosting voltage by 26%<br />

Response from <strong>UPS</strong>: AVRBOOST2<br />

If the <strong>UPS</strong> is in AVR mode and bucking voltage by 11%<br />

Response from <strong>UPS</strong>: AVRBUCK1<br />

If the <strong>UPS</strong> is in BATTERY mode<br />

Response from <strong>UPS</strong>: BATTERY<br />

Request Load Level Status<br />

Transmit the load level percentage.<br />

Send to <strong>UPS</strong>:<br />

Response from <strong>UPS</strong>:<br />

<strong>LOAD</strong>STAT<br />

XX%<strong>LOAD</strong><br />

XX is the load percentage represented<br />

in ASCII.<br />

Request Battery Charge Level Status<br />

Transmit the remaining battery charge percentage.<br />

MAIN_OFF<br />

NCL_ON<br />

NCL_OFF<br />

BATTHRESH<br />

BEEPON<br />

BEEPOFF<br />

RESTORE<br />

OUTLETSTAT<br />

INPUTVOLTS<br />

OUTPUTSTAT<br />

<strong>LOAD</strong>STAT<br />

BATTERYSTAT<br />

ID<br />

HELP<br />

Send to <strong>UPS</strong>:<br />

Response from <strong>UPS</strong>:<br />

BATTERYSTAT<br />

XX%BATTERY<br />

XX is the battery charge percentage<br />

represented in ASCII.<br />

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901<br />