Zero setting of zero point (0%, 25%, 50%, 75% of nominal value) Functions Zero Fine fine setting of zero point (0% ... 25% of nominal value) Span span (100%, 75%, 50%, 25% of nominal value) Range measuring range reversible between 5A, 10A, 15A G2IA15A 4...20mA in 3-phase mains G2IA15A 4...20mA in 3-phase mains with current transformer Connections Loadmonitors Series GAMMA Power factor monitoring (cosj) in 1- or 3-phase mains < Multifunction (G2CM) < Underload monitoring (G2CU) < Fault latch < Recognition of disconnected consumers I=0 < Suitable for VFI (10 to 100Hz) < Supply voltage selectable via PowerModules < 2 CO contacts (G2CM); 1 CO contact (G2CU) < Width 22,5mm < Industrial design L N L1 N types G2CM400V10AL20 G2CM400V2AL20 G2CU400V10AL10 i k A1 i k A1 X1 X2 A2 X1 X2 A2 Art.No. (PQ1) 2390602 2390606 2390600 Last 4...20mA Last 4...20mA Art.No. (PQ10) - - - EAN13-Code 900866200289 900866200290 900866200288 Width 22,5mm Dimensions Measured variable Power factor (cosj) of 1- or 3-phase loads AC Sinus (10 to 100Hz) Power factor (cosj) of 1- or 3-phase loads AC Sinus (10 to 100Hz) Power factor (cosj) of 1- or 3-phase loads AC Sinus (10 to 100Hz) Measured range 0,1 to 1 0,1 to 1 0,1 to 1 Measuring voltage 1-phase loads: 40 to 240VAC 3-phase loads: 3~ 40/23 to 415/240V 1-phase loads: 40 to 240VAC 3-phase loads: 3~ 40/23 to 415/240V 1-phase loads: 40 to 240VAC 3-phase loads: 3~ 40/23 to 415/240V Rated current 0,5 to 10A 0,05 to 2A 0,5 to 10A Controls Start • max • min • Delay • Function Start • max • min • Delay • Function Start • min • Delay • Function Indicators (LEDs) U/t • min • max • I=0 • R U/t • min • max • I=0 • R U/t • min • I=0 • R Functions OVER OVER+LATCH UNDER UNDER+LATCH WIN WIN+LATCH OVER OVER+LATCH UNDER UNDER+LATCH WIN WIN+LATCH UNDER UNDER+LATCH Switching threshold max. cosj = 0,2 to 1,0 cosj = 0,2 to 1,0 - Switching threshold min. cosj = 0,1 to 0,99 cosj = 0,1 to 0,99 cosj = 0,1 to 1,0 Hysteresis - - fixed, approx. 3° (according to 3% bei cosj=0,8) Tripping delay 0,1s to 40s 0,1s to 40s 0,1s to 40s Start-up suppression time 1s to 100s 1s to 100s 1s to 100s Fault latch selectable selectable selectable Supply PowerModule TR2 or SNT2 terminals A1-A2 PowerModule TR2 or SNT2 terminals A1-A2 PowerModule TR2 or SNT2 terminals A1-A2 Output 2 CO contacts; 250V, 5A AC 2 CO contacts; 250V, 5A AC 1 CO contact; 250V, 5A AC Width 22,5mm 22,5mm 22,5mm Certificates CE • cULus • GOST CE • cULus • GOST CE • cULus • GOST Mechanical design Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any • Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm Terminal capacity 1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end • 2 x 2,5mm² flexible without multicore cable end Ambient conditions Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27) Accessories PowerModules TR2 (12 - 440V AC) and DC power supply SNT2 24 VDC • sealable intervention protection shield FA-G2 Page 100 www.tele-online.com Page 101
OVER OVER+LATCH UNDER UNDER+LATCH WIN WIN+LATCH Overload monitoring Overload monitoring with fault latch Underload monitoring Underload monitoring with fault latch Monitoring the window between Min and Max Monitoring the window between Min and Max with fault latch Functions Connected to 3~ 400V mains with PowerModule 24V AC without fault latch. I N