Zero<br />

setting of zero point (0%, 25%, 50%, 75% of nominal value)<br />

Functions<br />

Zero Fine<br />

fine setting of zero point (0% ... 25% of nominal value)<br />

Span<br />

span (100%, 75%, 50%, 25% of nominal value)<br />

Range<br />

measuring range reversible between 5A, 10A, 15A<br />

G2IA15A 4...20mA in 3-phase mains G2IA15A 4...20mA in 3-phase mains with current transformer Connections<br />

Loadmonitors Series GAMMA<br />

Power factor monitoring (cosj) in 1- or 3-phase mains<br />

< Multifunction (G2CM)<br />

< Underload monitoring (G2CU)<br />

< Fault latch<br />

< Recognition of disconnected consumers I=0<br />

< Suitable for VFI (10 to 100Hz)<br />

< Supply voltage selectable via PowerModules<br />

< 2 CO contacts (G2CM); 1 CO contact (G2CU)<br />

< Width 22,5mm<br />

< Industrial design<br />

L<br />

N<br />

L1<br />

N<br />

types G2CM400V10AL20 G2CM400V2AL20 G2CU400V10AL10<br />

i k A1<br />

i k A1<br />

X1 X2 A2<br />

X1 X2 A2<br />

Art.No. (PQ1) 2390602 2390606 2390600<br />

Last<br />

4...20mA<br />

Last<br />

4...20mA<br />

Art.No. (PQ10) - - -<br />

EAN13-Code 900866200289 900866200290 900866200288<br />

Width 22,5mm<br />

Dimensions<br />

Measured variable<br />

Power factor (cosj) of<br />

1- or 3-phase loads<br />

AC Sinus (10 to 100Hz)<br />

Power factor (cosj) of<br />

1- or 3-phase loads<br />

AC Sinus (10 to 100Hz)<br />

Power factor (cosj) of<br />

1- or 3-phase loads<br />

AC Sinus (10 to 100Hz)<br />

Measured range 0,1 to 1 0,1 to 1 0,1 to 1<br />

Measuring voltage<br />

1-phase loads: 40 to 240VAC<br />

3-phase loads: 3~ 40/23 to 415/240V<br />

1-phase loads: 40 to 240VAC<br />

3-phase loads: 3~ 40/23 to 415/240V<br />

1-phase loads: 40 to 240VAC<br />

3-phase loads: 3~ 40/23 to 415/240V<br />

Rated current 0,5 to 10A 0,05 to 2A 0,5 to 10A<br />

Controls Start • max • min • Delay • Function Start • max • min • Delay • Function Start • min • Delay • Function<br />

Indicators (LEDs) U/t • min • max • I=0 • R U/t • min • max • I=0 • R U/t • min • I=0 • R<br />

Functions<br />

OVER<br />

OVER+LATCH<br />

UNDER<br />

UNDER+LATCH<br />

WIN<br />

WIN+LATCH<br />

OVER<br />

OVER+LATCH<br />

UNDER<br />

UNDER+LATCH<br />

WIN<br />

WIN+LATCH<br />

UNDER<br />

UNDER+LATCH<br />

Switching threshold max. cosj = 0,2 to 1,0 cosj = 0,2 to 1,0 -<br />

Switching threshold min. cosj = 0,1 to 0,99 cosj = 0,1 to 0,99 cosj = 0,1 to 1,0<br />

Hysteresis - - fixed, approx. 3°<br />

(according to 3% bei cosj=0,8)<br />

Tripping delay 0,1s to 40s 0,1s to 40s 0,1s to 40s<br />

Start-up suppression time 1s to 100s 1s to 100s 1s to 100s<br />

Fault latch selectable selectable selectable<br />

Supply<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

Output 2 CO contacts; 250V, 5A AC 2 CO contacts; 250V, 5A AC 1 CO contact; 250V, 5A AC<br />

Width 22,5mm 22,5mm 22,5mm<br />

Certificates CE • cULus • GOST CE • cULus • GOST CE • cULus • GOST<br />

Mechanical<br />

design<br />

Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •<br />

Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm<br />

Terminal capacity<br />

1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />

• 2 x 2,5mm² flexible without multicore cable end<br />

Ambient<br />

conditions<br />

Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to<br />

+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:<br />

3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g<br />

11ms (in accordance with IEC 60068-2-27)<br />

Accessories<br />

PowerModules TR2 (12 - 440V AC) and DC power supply SNT2 24 VDC • sealable intervention protection shield FA-G2<br />

Page 100 www.tele-online.com<br />