2MIN<br />

Underload monitoring for two independent thresholds<br />

2MAX<br />

Underload monitoring for two independent thresholds<br />

WIN<br />

Monitoring of the threshold level between min and max areas<br />

MIN/MAX<br />

Underload and overload monitoring for two independent thresholds<br />

I< Detection of shorted loads with selectable relay setting<br />

Functions<br />

Loadmonitors Series GAMMA<br />

True power monitoring of 1- or 3-phase loads<br />

< Multifunction<br />

< Fault latch<br />

< Recognition of disconnected consumers<br />

< Suitable for VFI (10 to 100Hz)<br />

< Supply voltage selectable via PowerModules<br />

< 1 CO contact; 2 CO contacts<br />

< Width 22,5mm or 45mm<br />

< Industrial design<br />

Connected 3~ 400V with power module 400V AC with fault latch<br />

I N<br />

12A<br />

Connections<br />

L1<br />

L2<br />

L3<br />

L1<br />

L2<br />

L3<br />

types G2BM480V12AFL10 G2BM400V12AL10 G2BM400V12AFL10<br />

Reset<br />

Reset<br />

A1 i k<br />

A1 i k<br />

L1<br />

L2<br />

L3<br />

L1<br />

L2<br />

L3<br />

15<br />

25<br />

15<br />

25<br />

16 18<br />

26 28<br />

16 18<br />

26 28<br />

Y1<br />

Y2<br />

16 18<br />

15<br />

A2<br />

T1<br />

T2<br />

26<br />

25<br />

28<br />

Y1<br />

Y2<br />

16 18<br />

15<br />

A2<br />

T1<br />

T2<br />

26<br />

25<br />

28<br />

Art.No. (PQ1) 2390707 2390700 2390702<br />

Art.No. (PQ10) - - -<br />

EAN13-Code 9008662006119 900866200291 900866200292<br />

Connected 3~ 400V with power module 400V AC with fault latch<br />

and current transformer I N<br />

12A<br />

Connections<br />

Measured variable<br />

True power consumption 1- or 3-phase loads<br />

AC Sinus (10 to 400Hz)<br />

True power consumption of 1- or 3-phase loads<br />

AC Sinus (10 to 400Hz)<br />

True power consumption of 1- or 3-phase loads<br />

AC Sinus (10 to 400Hz)<br />

Measuring ranges P N<br />

0,75kW • 1,5kW • 3kW • 6kW 0,5kW • 1kW • 2kW • 4kW 0,5kW • 1kW • 2kW • 4kW<br />

L1<br />

L2<br />

L3<br />

Reset<br />

L1<br />

L2<br />

L3<br />

24V~<br />

0V<br />

Measuring voltage<br />

Measuring range Current<br />

1-phase loads: 0 to 480V AC<br />

3-phase loads: 3~ 0 to 480/277V<br />

Measuring ranges 0,75 and 1,5kW: 0 to 6A<br />

Measuring ranges 3 and 6kW: 0 to 12A<br />

1-phase loads: 0 to 415VAC<br />

3-phase loads: 3~ 0 to 415/240V<br />

Measuring ranges 0,5 and 1kW: 0 to 6A<br />

Measuring ranges 2 and 4kW: 0 to 12A<br />

1-phase loads: 0 to 415VAC<br />

3-phase loads: 3~ 0 to 415/240V<br />

Measuring ranges 0,5 and 1kW: 0 to 6A<br />

Measuring ranges 2 and 4kW: 0 to 12A<br />

Controls Start • Power • Delay • Range • Function Start • Power • Delay • Range • Function Start • Power • Delay • Range • Function<br />

A1 i k<br />

A1 i k<br />

Indicators (LEDs) U/t • Failure • I=0 • R U/t • Failure • I=0 • R U/t • Failure • I=0 • R<br />

L1<br />

L2<br />

15<br />

25<br />

L3<br />

L1<br />

L2<br />

15<br />

25<br />

L3<br />

Functions OVER + I=0<br />

OVER + I=0<br />

UNDER<br />

UNDER + I=0<br />

OVER<br />

OVER + I=0<br />

UNDER<br />

UNDER + I=0<br />

OVER + I=0<br />

OVER + I=0<br />

UNDER<br />

UNDER + I=0<br />

16 18<br />

26 28<br />

16 18<br />

26 28<br />

Trigger level P 5% to 120% from P N<br />

5% to 120% of P N<br />

5% to 120% of P N<br />

Y1<br />

Y2<br />

16 18<br />

15<br />

A2<br />

T1<br />

T2<br />

26<br />

25<br />

28<br />

Y1<br />

Y2<br />

16 18<br />

15<br />

A2<br />

T1<br />

T2<br />

26<br />

25<br />

28<br />

Hysteresis fixed, approx. 3% from P N<br />

fixed, approx. 3% of P N<br />

fixed, approx. 3% of P N<br />

Tripping delay 0,1s to 2s 0,1s to 50s 0,1s to 2s<br />

Start-up suppression time 0,1s to 2s 1s to 100s 0,1s to 2s<br />

Fault latch wire link Y1-Y2 wire link Y1-Y2 wire link Y1-Y2<br />

Width 45mm<br />

Dimensions<br />

Supply<br />

Output<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

1 CO contact<br />

250V 5A AC<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

1 CO contact<br />

250V 5A AC<br />

PowerModule TR2 or SNT2<br />

terminals A1-A2<br />

1 CO contact<br />

250V 5A AC<br />

Width 22,5mm 22,5mm 22,5mm<br />

Certificates CE • GOST CE • GOST CE • GOST<br />

Powermodul<br />

Mechanical<br />

design<br />

Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •<br />

Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm<br />

90mm<br />

Terminal capacity<br />

1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />

•2 x 2,5mm² flexible without multicore cable end<br />

103mm<br />

5mm<br />

45mm<br />

Ambient<br />

conditions<br />

Accessories<br />

Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to<br />

+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:<br />

3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g<br />

11ms (in accordance with IEC 60068-2-27)<br />

PowerModules TR2 (12 - 440V AC) and DC power supply SNT2 24VDC • sealable intervention protection shield FA-G2<br />

Page 94<br />

www.tele-online.com Page 95