SERIES<br />

Design<br />

GAMMA<br />

Industrie<br />

True power monitors<br />

Current<br />

COSφ - Monitors<br />

Function<br />

Underload detection 5) 5) <br />

Overload detection 5) 5) 1) 1)<br />

Under- and overload detection (Window) 5) 5) 1) 1)<br />

I=0 (zero current-) detection 2) <br />

Temperature monitoring for motor windings <br />

Configurable threshold 5) 5) <br />

Configurable hysteresis 3) 5) 5) <br />

Fault storage 5) 5) <br />

Override on start-up 4) 5) 5) <br />

Tripping delay 5) 5) <br />

Reduced tripping times <br />

Digital control <br />

Outputs<br />

1 CO contact <br />

2 CO contacts <br />

Current rating 16A 16A 12A 12A 12A 12A 12A 12A 12A 12A 15A 10A 2A 10A<br />

Analogue output<br />

Measured voltage<br />

4 -<br />

20mA<br />

4 -<br />

20mA<br />

400/690V AC<br />

400/690V AC<br />

277/480V AC<br />

277/480V AC<br />

277/480V AC<br />

277/480V AC<br />

277/480V AC<br />

230/400V AC<br />

277/480V AC<br />

277/480V AC<br />

230/400V AC<br />

230/400V AC<br />

230/400V AC<br />

Mains voltage<br />

12 - 500V AC<br />

12 - 500V AC<br />

12 - 500V AC<br />

24 - 240V AC/DC<br />

12 - 500V AC<br />

12 - 500V AC<br />

12 - 400V AC<br />

12 - 400V AC<br />

12 - 400V AC<br />

24 - 240V AC/DC<br />

24 - 240V AC/DC<br />

12 - 400V AC<br />

12 - 400V AC<br />

12 - 400V AC<br />

Type<br />

G4BM690V16ATL20<br />

G4BM690V16AL20<br />

G4BM480V12ADTL20<br />

G4BM480V12ADTL20 24-240V AC/DC<br />

G4BM480V12ATL20<br />

G4BM480V12AFTL20<br />

G2BM480V12AFL10<br />

G2BM400V12AL10<br />

G2BM480V12AFL10<br />

G2BA480V12A<br />

G2IA15A<br />

G2CM400V10AL20<br />

G2CM400V2AL20<br />

G2CU400V10AL10<br />

Technical data page 89 89 91 91 93 93 95 95 95 97 99 101 101 101<br />

1) Due to cos φ characteristics maximum detection is only possible within underload range of the motor.<br />

2) Optional detection of disconnected load. A standby condition of the monitoring relay will be triggered.<br />

3) For two-point controller, the differential gap (hysteresis) can be set separately. It‘s the difference between the upper and lower threshold.<br />

4) Time function which disables an error message during start up; this enables a start-up without shut off from inrush load.<br />

5) Monitoring and controlling functions via PLC.<br />