catalog TELE - CONTA-CLIP
catalog TELE - CONTA-CLIP
catalog TELE - CONTA-CLIP
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
E1UM<br />
AC/DC voltage monitoring in 1-phase mains with adjustable thresholds and hysteresis.<br />
UNDER Undervoltage monitoring<br />
WIN<br />
Monitoring the window between Min and Max<br />
E1UU<br />
AC/DC UNDERvoltage monitoring in 1-phase mains with adjustable threshold and fixeded hysteresis.<br />
UNDER Undervoltage monitoring<br />
E1UM; E1UU<br />
Functions<br />
Connections<br />
Sensing & Monitoring Relays Series ENYA<br />
Current monitoring<br />
< AC/DC current monitoring (E3IM)<br />
< AC current monitoring (E1IM; E1IU)<br />
< Multifunction (E1IM; E3IM)<br />
< Undercurrent monitoring (E1IU)<br />
< Supply voltage 230V (E3IM - galvanically separated)<br />
< 1 CO contact; 2 CO contacts<br />
< Width 17,5mm; 35mm<br />
< Installation design<br />
1~<br />
230V<br />
AC<br />
L<br />
N<br />
E<br />
F3<br />
F1<br />
F2<br />
1~<br />
24V<br />
AC<br />
L<br />
N<br />
E F1<br />
F3 F2<br />
24V<br />
DC<br />
+<br />
-<br />
E F1<br />
F3 F2<br />
types E3IM10AL20 E1IM10AACL10 E1IU5AAC01 E1IU500mAAC01<br />
11<br />
R<br />
11<br />
R<br />
11<br />
R<br />
12 14<br />
12 14<br />
12 14<br />
11<br />
12 14<br />
11<br />
12 14<br />
11<br />
12 14<br />
Art.No. (PQ1) 1341200 1340200 1340201 1340204<br />
Art.No. (PQ10) - - - -<br />
EAN13-Code 900866200594 900866200486 900866200504 9008662005341<br />
Width 17,5mm<br />
Dimensions<br />
Measured variable<br />
Measuring ranges<br />
Current<br />
AC/DC Sinus (16 to 400Hz)<br />
100mA AC/DC; terminals k-I1<br />
1A AC/DC; terminals k-I2<br />
10A AC/DC; terminals k-I3<br />
Current<br />
AC Sinus (48 to 63Hz)<br />
Current<br />
AC Sinus (48 to 63Hz)<br />
Current<br />
AC Sinus (48 to 63Hz)<br />
10A AC; terminals Li-Lk 5A AC; terminals Li-Lk 500mA AC; terminals Li-Lk<br />
Controls<br />
Start • Max • Min • Function •<br />
Delay<br />
Delay • Max • Min • Function I S<br />
I S<br />
Indicators (LEDs) U/t • Max • Min • R U/t • Max • Min • R U • R U • R<br />
5mm<br />
44mm<br />
60mm<br />
45mm<br />
87mm<br />
17,5mm<br />
Functions<br />
OVER<br />
OVER+LATCH<br />
UNDER<br />
UNDER+LATCH<br />
WIN<br />
WIN+LATCH<br />
OVER<br />
OVER+LATCH<br />
UNDER<br />
UNDER+LATCH<br />
WIN<br />
WIN+LATCH<br />
UNDER<br />
UNDER<br />
Switching<br />
10% to 100% of I<br />
threshold max.<br />
N<br />
10% to 100% of I N<br />
- -<br />
Switching<br />
5% to 95% of I<br />
threshold min.<br />
N<br />
5% to 95% of I N<br />
10% to 100% of I N<br />
10% to 100% of I N<br />
Hysteresis adjustable adjustable fixed, 10% fixed, 10%<br />
Tripping delay 0,1s to 10s 0,1s to 10s - -<br />
Start-up suppression time 0s to 10s - - -<br />
Fault latch selectable selectable - -<br />
Supply<br />
230V AC<br />
terminals A1-A2<br />
-15% to +15%<br />
230V AC<br />
terminals Li-N<br />
-15% to +15%<br />
230V AC<br />
terminals Li-N<br />
-15% to +15%<br />
230V AC<br />
terminals Li-N<br />
-15% to +15%<br />
Output<br />
2 CO contacts<br />
250V, 5A AC<br />
1 CO contact<br />
250V, 5A AC<br />
1 CO contact<br />
250V, 5A AC<br />
1 CO contact<br />
250V, 5A AC<br />
Width 35mm 17,5mm 17,5mm 17,5mm<br />
Certificates CE CE • cULus • GOST CE • cULus • GOST CE • cULus • GOST<br />
Mechanical<br />
design<br />
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •<br />
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm<br />
Terminal capacity<br />
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />
• 2 x 2,5mm² flexible without multicore cable end<br />
Ambient<br />
conditions<br />
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to<br />
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)<br />
Accessories<br />
Mounting plate MP; Current transformer Series DSW and WSW<br />
Page 76<br />
www.tele-online.com Page 77