18.01.2015 Views

catalog TELE - CONTA-CLIP

catalog TELE - CONTA-CLIP

catalog TELE - CONTA-CLIP

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Functions<br />

Coupling units Series OCTO<br />

Automatic-Manual-OFF relay<br />

< Three-way switch: Automatic, permanently OFF or ON<br />

< Checkback signal of the switch setting AUTO<br />

< 1 CO contact<br />

< Width 17,5mm<br />

< Installation design<br />

E1K E3K Connections<br />

U ~<br />

(+)<br />

(+)<br />

U ~<br />

Type<br />

HAR1<br />

(-)<br />

(-)<br />

15<br />

11<br />

21<br />

A1<br />

A1<br />

A1<br />

15<br />

A1<br />

11<br />

21<br />

R<br />

R<br />

R<br />

A2 16 18<br />

A2 12 14 22 24<br />

A2<br />

16 18<br />

12<br />

A2<br />

14<br />

22 24<br />

Art.No. (PQ1) 170010<br />

Art.No. (PQ10) -<br />

EAN13-Code 900866200067<br />

Width 17,5mm Width 35mm Dimensions<br />

Controls<br />

Indicators (LEDs)<br />

Functions<br />

Control input<br />

Function<br />

R<br />

AUTO (automatic) • 0 (permanently OFF) • HAND (permanently ON)<br />

control voltage for automatic operation<br />

24V AC/DC<br />

terminals A3-A2<br />

Output<br />

1 potential free CO contact<br />

250V AC, 8A<br />

45mm<br />

87mm<br />

45mm<br />

87mm<br />

Checkback<br />

1 potential free NO contact for checkback signal of the switch setting AUTO<br />

48V AC/DC; 500mA<br />

terminals B1-B2<br />

Supply<br />

24V AC/DC<br />

terminals A1-A2<br />

Width<br />

17,5mm<br />

5mm<br />

44mm<br />

60mm<br />

17,5mm<br />

5mm<br />

44mm<br />

60mm<br />

35mm<br />

Certificates<br />

Mechanical<br />

design<br />

CE • GOST<br />

Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •<br />

Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm<br />

Terminal capacity<br />

1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />

• 2 x 2,5mm² flexible without multicore cable end<br />

Ambient<br />

conditions<br />

Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to<br />

+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC<br />

60664-1)<br />

Accessories -<br />

Page 226<br />

www.tele-online.com<br />

Page 227

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!