The 8 normally open contacts, as well as the alarm or synchronisation contact, are operated according to the internally saved,<br />
time-dependent sequences of steps (programmes). The sequences can run once (E) or cyclically (Z).<br />
The individual steps are defined by a programmed time interval and the associated condition of all output relays (output mask). Any<br />
changes to the condition of the output relays therefore require the programming of a new step.<br />
The time-controlled processing of the sequence can be influenced by using the 3 input channels. The product is supplied with a factory<br />
default setting.<br />
Control input<br />
Functions<br />
Connections<br />
Pump Alternator Series GAMMA<br />
Alternating or prallel operation of motors<br />
< Alternated access of two pumps or other devices<br />
< Even distribution of duty<br />
< Parallel duty at high demand<br />
< Operation using 1 or 2 input signals (two modes of operation)<br />
< Timing offset of the two loads to avoid water hammer effects<br />
< Supply voltage selectable via TR2 PowerModules or DC power supply<br />
< 2 separate change over relays for device control<br />
< Width 22,5mm<br />
< Industrial design<br />
factory default<br />
RESET, TRIGGER, STOP<br />
Type<br />
G2ASMA20<br />
Art.No. (PQ1) 122000<br />
Art.No. (PQ10) -<br />
EAN13-Code 900866200033<br />
Controls<br />
TIME/MODE<br />
Outputs<br />
Connections<br />
Indicators (LEDs)<br />
U/t • Failure • R1 • R2<br />
Functions<br />
One of two redandant motors will operate on demand signalised by input Y1. Successive requests will operate the motors in an alternating<br />
sequence (sharing the duty between the devices). On demand both devices (pumps) will operate in parallel:<br />
Mode A (parallel operation by separate input signal): Input Y2 initiates parallel operation. Without signal at input Y2, only one single motor will<br />
operate at each request.<br />
Mode B (parallel operation by timing): If an operation request on input Y1 exceeds the ajdusted delay, the unit will start the second motor for<br />
parallel operation.<br />
Time ranges t 1<br />
(for parallel operation): 2s to 5min (only for mode B)<br />
t 2<br />
(offset timing): 2s fixed<br />
Control input<br />
control input Y1: request for operation; terminals Y1-Y3<br />
control input Y2: parallel operation (Mode A only); terminals Y2-Y3<br />
input circuits galvanic separated<br />
Supply<br />
PowerModule TR2 or SNT2<br />
terminals A1-A2<br />
Contactors<br />
Supply voltage<br />
Output<br />
Width<br />
2 potential free CO contacts<br />
250V AC, 5A<br />
22,5mm<br />
Certificates<br />
CE<br />
Width 157,5mm<br />
Dimensions<br />
Mechanical<br />
design<br />
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •<br />
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm.<br />
Terminal capacity<br />
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />
• 2 x 2,5mm² flexible without multicore cable end<br />
Ambient<br />
conditions<br />
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to<br />
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:<br />
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g<br />
11ms (in accordance with IEC 60068-2-27)<br />
Accessories<br />
PowerModulee TR2 (12 - 440V AC) • DC power supply SNT2 24VDC<br />